• 제목/요약/키워드: Wall paper

검색결과 2,978건 처리시간 0.033초

고유치해석과 진동계측을 통한 벽식 공동주택의 고유주기 비교 (Comparison of the Natural Period Obtained by Eigenvalue Analysis and Ambient Vibration Measurement in Bearing-Wall Type Apartment)

  • 윤성원;정석창;임인식
    • 한국공간구조학회논문집
    • /
    • 제6권3호
    • /
    • pp.43-50
    • /
    • 2006
  • This paper is concerned with the natural periods of ambient vibration and eigenvalue analysis. Ambient vibration tests were conducted to four bearing-wall reinforced concrete buildings ranging from twelve to nineteen stories. The performance of modeling in eigenvalue analysis was investigated using consideration of rigidity out of the plane in the slab and the non-structural bearing wall. Measured natural period was also compared with the value by the KBC2005. Natural period of the short direction in eigenvalue analysis is well fitted with the measured one. In the other hand, Natural period of the long direction in eigenvalue analysis is slightly more overestimated than the measured one. Natural period of the long direction in eigenvalue analysis was found to be enhanced by considering the effect of the stiffness out of the plane of the slab and non-structural wall in the structural modeling.

  • PDF

디젤기계의 피스톤 열부하 특성에 관한 연구 (Themally Loaded Characteristics of Diesel Engine Piston)

  • 한문식;박태인
    • 한국기계연구소 소보
    • /
    • 통권15호
    • /
    • pp.91-103
    • /
    • 1985
  • In this paper, temperature distribution and thermal stress are investigated considering engine peak pressure and the time average temperature distribution in the piston under running conditions for the diesel engine. The induced stress are calculated by the Finite Element Method(FEM). The results obtained are summerized as follows. 1) The results calculated by the FEM present good agreement with other numerical solution in literature. 2) It is confirmed that maximum compressive stress are induced in the part of outside wall between the piston crown and the pin bush. 3) In the axial direction, the hoop stresses are changed its sigh at the portion of crown near the inner wall side 4)Large gradient of temperature is shown in the piston crown near the side wall in the axial direction, in the part between the piton crown and the pin bush in radical direction 5)in case of stress distribution of piston wall surface in the axial direction, the hoop stress is a little greater than axial stress, and the latter is greater than the radial stress

  • PDF

보강토 옹벽의 지진시 거동에 관한 유한요소해석 (Finite Element Analysis of Soil-Reinforced Segmental Retaining Walls Subjected to Earthquake Loading)

  • 유충식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.101-108
    • /
    • 2000
  • This paper presents the results of finite element analysis on the seismic response of a soil-reinforced segmental retaining wall subjected to a prescribed earthquake record. The results of finite element analysis indicate that the maximum wall displacement occurs at the top, exhibiting a cantilever type of wall movement. Also revealed is that the increase in reinforcement force is more pronounced in the upper part of the reinforced zone, resulting in a more or less uniform distribution. None of the design guidelines appears to be able to correctly predict the dynamic force increase when compared with the results of finite element analysis. The results demonstrated that there exist critical stiffness and length of reinforcement beyond which further increase would not contribute to additional reinforcing effect. Based on the findings from this study, a number of implications to the current design methods are discussed.

  • PDF

억지말뚝을 이용한 자립식 흙막이 공법의 개발 (A Study on a Self-supported Earth Retaining Wall with Stabilizing Piles)

  • 심재욱;백성권
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1461-1467
    • /
    • 2005
  • In this study, a new earth retention system has been developed and introduced. This system is a self-supported earth retaining wall without struts. The new earth retention system consists of connected double H-pile and wale. This system provides a larger spacing of support, economical benefit, construction easiness, good performance and safety. This paper explains basic principles and mechanism of self-supported earth retaining wall. In order to investigate applicability and safety of this system, numerical analysis was performed. The finite differential method program, FLAC3D is used. The predicted performances of this system were presented and discussed.

  • PDF

축소모형실험을 이용한 지반굴착시 주변 지반 거동 연구 (Laboratory investigation on deep excavation-induced ground movements)

  • 유충식;이성우;이봉원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1476-1483
    • /
    • 2005
  • This paper presents the results of small scale model tests on the behavior of propped wall and ground movements during deep excavation. Small scale model tests were performed in order to investigate the effects of various influencing factors on the deep excavation, such as stiffness of ground and unsupported span length. The results of model tests indicated that the wall behavior is significantly influenced not only by the stiffness of ground but by the over-excavation, and that the wall behavior can be reduced by decreasing the unsupported span length and increasing the stiffness of ground.

  • PDF

보강토 옹벽 전면블록의 연결강도 및 마찰특성 평가 (Assessment of Connection Strength and Frictional Characteristic for The Segmental Retaining Wall Unit)

  • 김진만;조삼덕;오세용;이대영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1562-1571
    • /
    • 2005
  • The use of geogrid for SRW systems and bridge abutment has increased rapidly over the past 10 years in Korea. The concept of segmental retaining walls and reinforced soil is very old and for example The Ziggurats of Babylonia(i.e. Tower of Babel) were built some 2,500 to 3,000 years ago using soil reinforcing methods very similar to those described in current design. Modern SRW(Semental Retaining Wall) units were introduced in 1960's as concrete crib retaining wall systems. In this paper, the friction properties between segmental concrete units and geogrid are investigated by performing various tests.

  • PDF

Brief Review of Studies on Concrete Wall Panels in One and Two Way Action

  • Doh, Jeung-Hwan;Fragomeni, Sam;Kim, Jin-Woo
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제4권1호
    • /
    • pp.38-43
    • /
    • 2001
  • This paper provides review of research results undertaken on reinforced concrete wall panels in one way and two way. The review also highlights two well accepted code design methods from the American (ACI) and Australia Concrete structures standards. The emphasis is on walls under axial compression only with changes in various parameters. These include the variation of panel dimensions panels (ie. Slenderness, thinness and aspect ratios), steel reinforcement, eccentricities, concrete strength and support conditions. The main purpose of this review is to compile research previous by undertaken to highlight the inadequate in certain research literature. It is envisage that this review will expose areas in wall research required so that inadequate in current methods can be rectified.

  • PDF

Higher Order Wall Boundary Conditions for Incompressible Flow Simulations

  • Nishida Hidetoshi
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.61-62
    • /
    • 2003
  • In this paper, the new higher order wall boundary conditions are proposed for solving the incompressible flows. The square driven cavity flows are simulated by using the variable order method of lines with the present wall boundary conditions. The variable order method of lines is constructed by the spatial discretization, i.e., the variable order proper convective scheme for convective terms and the modified differential quadrature method for diffusive terms, and time integration. The 2nd, 4th, and 6th order solutions are presented and these results show this higher order boundary conditions are very promising for the incompressible flow simulations.

  • PDF

Approximate Coordinate Transformations for Simulation of Turbulent Flows with Wall Deformation

  • Kang, Sangmo
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.703-709
    • /
    • 2002
  • In the present paper, approximate coordinate transformations for simulation of turbulent flows with wall deformation, significantly reducing computational cost with little degradation in numerical accuracy, are presented. The Wavier-Stokes equations are coordinate-transformed with an approximation of Tailor-series truncation. The performance is evaluated by performing numerical simulations of a channel flow at Re$\sub$$\tau$/ = 140 with active wall motions of η$\sub$m/$\^$+/ $\leq$5. The approximate transformations provide flow structures as well as turbulence statistics in good agreement with those from a complete transformation [Phys. Fluids 12, 3301 (2000) ] and allow 25-30% savings in the CPU time as compared to the complete one.

관통균열이 존재하는 증기발생기 전열관의 파열압력 평가 (Burst Pressure Evaluation for Through-Wall Cracked Tubes in the Steam Generator)

  • 김현수;김종성;진태은;김홍덕;정한섭
    • 대한기계학회논문집A
    • /
    • 제28권7호
    • /
    • pp.1006-1013
    • /
    • 2004
  • Operating experience of steam generators shows that the tubes are degraded by stress corrosion cracking, fretting wear and so on. These defected tubes could stay in service if it is proved that the tubes have sufficient structural margin to preclude the risk of tube bursting. This paper provides detailed plastic limit pressure solutions for through-wall cracks in the steam generator tubes. These are developed based on three dimensional(3D) finite element analyses assuming elastic-perfectly plastic material behavior. Both axial and circumferential through-wall cracks in free span and in u-bend regions are considered. The resulting limit pressure solutions are given in a polynomial form, and thus can be simply used in practical integrity assessment of the steam generator tubes.