• 제목/요약/키워드: Wall Loss

검색결과 785건 처리시간 0.03초

동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석 (Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell)

  • 강은철;박용대;이의준;윤태권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

공기 중 탄소나노튜브 시료채취 시 사용하는 카세트 종류가 벽면 손실에 미치는 영향 (Effect of Sampling Cassettes Type used in Sampling of Airborne Carbon Nanotube(CNT) to Electrostatic Loss)

  • 함승헌;김송하;이진호;이나루;윤충식
    • 한국산업보건학회지
    • /
    • 제27권3호
    • /
    • pp.180-186
    • /
    • 2017
  • Objectives: The purposes of this study were to compare the surface resistance of cassettes according to the material, and to evaluate the wall deposition of carbon nanotubes(CNTs) by electrostatic loss in the inner wall of the cassette. Methods: Surface resistance was measured for three types of cassettes(25 mm polypropylene conductive cowl, 25 mm and 37 mm clear styrene cassettes) with a surface resistance meter. Also, electrostatic wall loss was measured at different weights of CNTs depending on the cassette. CNTs were laid on a weight dish with the cassette for five minutes to provide sufficient time to attach on the wall. Wipe sampling was performed to collect CNTs deposited on the wall and elemental carbon, known as a surrogate for CNTs, was analyzed. Results: The cassette with conductive materials(18% of black carbon) showed the lowest surface resistance($<1.21{\times}10^3{\Omega}$). Cassettes made from clear polystyrene showed the relatively highest surface resistance(25 mm: $10.02{\times}10^9{\Omega}$, 37 mm: $10.59{\times}10^9{\Omega}$). This means that particles are more likely to stick to the internal wall of styrene cassettes due to electrostatic electricity. This may lead to an underestimation of the airborne concentration of CNTs. The experiment showed that EC was not detected when using a 25 mm conductive cowl cassette, while EC was detected at the internal wall of 25 mm and 37 mm polystyrene cassettes. Conclusions: This study confirms that cassettes with a conductive cowl have low surface resistance and are more appropriate for CNT sampling. In addition, this finding could be applied for other types of particulate, especially regarding electrostatic charge and sampling.

Computed tomographic features of focal lipogranulomatous lymphangitis for differentiating from malignant intestinal lesions in a dog

  • Hye-Won Lee;Jin-Woo Jung;Seungjo Park;Kija Lee;Sang-Kwon Lee
    • Journal of Veterinary Science
    • /
    • 제24권2호
    • /
    • pp.25.1-25.6
    • /
    • 2023
  • An eight-year-old Maltese dog presented with diarrhea and anorexia. Ultrasonography revealed marked focal wall thickening with loss of layering in the distal ileum. Contrast-enhanced computed tomography (CT) revealed a preserved wall layer with hypoattenuating middle wall thickening. In some segments of the lesion, small nodules protruding toward the mesentery from the outer layer were observed. Histopathology revealed focal lipogranulomatous lymphangitis (FLL) with lymphangiectasia. This is the first report to describe the CT features of FLL in a dog. CT features of preserved wall layers with hypoattenuating middle wall thickening and small nodules can assist in diagnosing FLL in dogs.

Experimental verification and improvement of heat transfer tube local wall temperature measurement method

  • Jiabao Liu;Xiaxin Cao;Peixun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4317-4328
    • /
    • 2023
  • To ensure the measuring accuracy of the wall temperature, the outer wall temperature measurement values by using three kinds of thermocouple welding methods were analyzed and evaluated in the paper, including single-point flush-mounted in the wall groove method, single-point insert-mounted in the wall groove, and outer surface direct welding method, based on the application of a tube-in-tube condensing heat exchanger. And the impacts of silver, tin, and thermal resistance adhesive as filling materials on wall temperature measurement were also investigated, and the results were compared to that obtained without filling materials. The results showed that the wall temperatures measured by the three welding methods were lower than the theoretically calculated value. And the wall temperature measured by the outer surface direct welding method was lowest under the same experimental conditions. The wall temperatures measured by single-point flush-mounted and insert-mounted in the wall groove methods were also affected by different welding filling materials. It was found that the greater the thermal resistance of filling materials, the smaller the heat loss. By analyzing the reasons for the low measured value of wall temperature, a new wall temperature measurement method was developed to improve the accuracy of the current measurement method. Meanwhile, the outer wall temperature measurement experiments of vertical and horizontal heat transfer tubes were carried out to validate and calibrate the improved outer wall temperature measurement method. The results showed that the average outer wall temperature deviation measured by the improved wall temperature measurement method ranged from - 0.82% to +2.29% for vertical tubes and - 4.75% to - 1.44% for horizontal tubes, and the improved measurement method had good measurement accuracy.

다수의 자계벽을 갖는 프로펠러 공진기형 서큘레이터 설계 (A Design for Propeller Resonators loaded Circulator with a plurality of symmetric magnetic walls)

  • 전동석;이홍열;김동영;이상석
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.91-95
    • /
    • 2002
  • This paper describes the design of planar circulators with propellers resonator including a plurality of symmetric magnetic walls. One purpose of the paper is to present insertion loss on this resonator for magnetic loss, dielectric loss, magnetic field and saturation magnetization. Another is to study the effect of propeller resonator on response characteristics. The paper includes the description of one commercial circulator that is compatible with the data obtained

  • PDF

투과손실을 이용한 틸팅차량의 실내소음 예측 (Prediction of Interior Noise for Tilting Train by using Transmission Loss)

  • 김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2007
  • In this paper, we describe the analysis of interior noise for tilting train that is being developed in Korea. Tilting train is made of composite material to reduce the car body's weight and attached a self-steering system on bogie to improve curving performance. However, the acoustic performance (Transmission Loss) of such material is worse than the materials of conventional train, such as aluminum, steel and so on. Therefore, we measure the transmission loss of side wall / floor of tiling train and predict the interior noise for tilting train using its measuring results

  • PDF

중단열 시스템의 문제점 분석 (Problem Analysis of Sandwich Insulation Wall System)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2015
  • Because of energy crisis at all around the world, there is many method and system which for improving energy efficiency has appeared in construction industry. And then, 20% of entire building energy loss is emissed to exterior of buildings, that is important to building's entire energy efficiency. So, many research has been conducted for imporve exterior energy efficiency and generally it called insulation of wall. Method for wall insulation can be classified interior system and exterior system which defined installation place of insulation board whether interior or exterior of structural wall. However, interior system has thermal problem such as thermal-bridge which can be necessarily occur condensation. and exterior system has constructional problem such as difficult to construction because exterior and finish work so expensive construction cost than other insulation method. Thus, sandwich insulation wall system has been appeared for solving these problems. Sandwich insulation system must using wall connecting things because both side walls is divided by center insulation. At this, Through the heat at wall connecter, it can be occured thermal-bridge and broken insulation board when under construction will be bring negative effect by reducing wall thickness and insulation deficit. At this study, we were compared previous sandwich insulation system and analysis these system's problem for develop the improving constructability and performance of sandwich insulation system.

  • PDF

기존 노후건축물의 최적 리모델링 개선안 연구 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;오세민
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.207-216
    • /
    • 2014
  • 에너지손실을 분석해 보면 열전달에 의한 손실과 공기유동에 의한 손실로 구분할수 있다. 열전달은 외벽, 지붕, 바닥의 열관류율에 의한 손실로 기존건축물의 가장 취약한 부분의 한 요소이다. 이런 손실을 방지 하려면 창을 포함한 외벽 전체의 평균 열관류율을 지역 기준값 이상으로 올리고 창의 기밀성을 확보함에 따라 방지 할수 있다. 노후건축물의 가장 취약한 부분이 외벽과 창호 이지만 출입문을 통한 침기량은 연돌효과에 의해 층계단을 타고 올라감과 동시에 각층의 공기를 흡입하여 더큰 유동을 잃으켜 층의 단열성 까지 취약하게 만드는 구조로 되어 있다. 현장 조사를 통한 진단과 에너지 개선처방이 제시될 때 반드시 건물전체에 대한 진단과 각층 부분에 대한 개선안이 함께 제출되어 단순히 창 교체만 하면 에너지절감을 이룰수 있다는 착각에서 벗어나야 할 것이다.

선행하중 재하시 지반손실 감소효과에 관한 연구 (A study on reduction effects of the ground loss in pre-loading)

  • 김봉유;조남준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.224-231
    • /
    • 2005
  • The ground excavation causes the deformation of the ground where the neighborhood structure is located. The ground deformation result in the vertical settlement of the neighborhood structure as well as the horizontal displacement of the temporary earth retaining structures. The decreased volume of the soil due to the ground settlement is defined as 'the ground loss quantity' or 'the ground loss'. When excavation is performed nearby existing structures, retaining walls should be designed and constructed to minimize the ground loss. Among various methods for reducing the ground loss, this study introduces the pre-loading method which has been recently developed. The reduction effect of the ground loss by pre-loading has been found to be larger as using a wall with relatively smaller rigidity.

  • PDF

공동주택 구조형태별 층간 공기전달음 차단 성능 (The Performance of Insulation of Noise by Air between Floors According to Structure Systems of Apartment)

  • 이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1152-1155
    • /
    • 2007
  • Lately concerns about structure have been increased by advantages of floor impact noise, poilitical induction and changeability. Hence, Flat Plate Structure has been constructed increasingly. This study shows the comparison of the performance of sound insulation of Flat Plate Structure System and the existing Wall Structure. For this study, taking the same level organization of Daelim Architectural Environmental Research Center, I found the performance of sound insulation between the upper and lower floors about Wall Structure and Flat Plate Structure. Consequently, the performance of sound insulation between upper and lower floors of Flat Plate Structure was 3-5dB higher was approximately 3-5dB higher than one of Wall Structure. Especially, the performance of sound insulation on the upper floor was 1-3dB higher than on the lower floor. In addition, as the result of comparing radiation sound which radiates from the wall of lower floors with each structure system, Flat Plate Structure was about 4dB higher with Rw than Wall Structure. As we see totally, the performance of sound insulation of Flat Plate Structure is highter than one of the Wall Structure. It is 3-5dB higher and the main reason for this result depends on the existence of the wall which can radiate sound and nonexistence.

  • PDF