• 제목/요약/키워드: Wall Jet

검색결과 361건 처리시간 0.035초

API강재의 파이버레이저 용접시 유기되는 플라즈마의 방사특성 (II) -용접조건과 방사신호의 관련성- (Characteristics of Plasma Emission Signals in Fiber Laser Welding of API Steel (II) -The Relationship between Welding Conditions and Emission Signals-)

  • 이창제;김종도;김유찬
    • Journal of Welding and Joining
    • /
    • 제30권4호
    • /
    • pp.24-30
    • /
    • 2012
  • Laser welding by fiber laser accompanied by a lot of spatter and humping bead. This is because the deep and narrow keyhole usually form due to high beam quality. So the weld bead is formed defects, because the plasma jet with a high vapor pressure make the molten pool on keyhole wall scattered. For such a reason, unstable behavior of keyhole is difficult to monitor laser welding by using the laser induced plasma. Mostly, fiber laser welding of thick plates most be influenced by this effect. Therefore, fiber laser welding has been difficult to apply the sole. Thus, laser welding monitoring based on plasma measurements have much difficulty in measurements and analysis of signal. In this study, influence of the plasma emission signal according to welding speed and laser power in fiber laser welding analysed by using RMS and FFT analysis. We can verify that RMS value of the plasma emission signal changes with welding parameters in fiber laser welding, and aspect ratio greater than 1, the peak of FFT frequency had been moved in accordance with welding parameter.

충격파 터널을 이용한 스크램제트 실험 기술 (Scramjet Experimental Techniques Using a Shock Tunnel)

  • 양성모;김근영;장원근;진상욱;박기수
    • 한국추진공학회지
    • /
    • 제22권5호
    • /
    • pp.97-106
    • /
    • 2018
  • 본 논문은 충격파 터널을 이용한 이중압축램프 흡입구 형상의 모델 스크램제트 시험에서 나타난 기술적 난제 및 그 해결 방안들을 정리하였다. 시험 설비 불시동, 격막 파편에 의한 유동 교란 및 모델 손상, 다중 분사에 따른 연료 제트 미발달, 그리고 짧은 시험 시간이 이에 해당한다. 파악된 기술적 난제들을 해결한 이후, 개선된 결과를 쉐도우그래프 이미지 및 저압관 끝단 전압력 측정 결과를 통해 확인하였다.

여수로에서 도수 수치해석 연구 (Numerical Investigation of Hydraulic Jump in a Spillway)

  • 백중철;류용욱;이남주
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.66-66
    • /
    • 2017
  • 하천에 설치된 저낙차 보의 여수로나 위어는 일반적으로 도수가 발생하도록 설계한다. 이러한 수공구조물위를 통과하는 흐름이 갖는 강한 운동에너지를 소산시키는데 도수는 중요한 역할을 한다. 난류흐름과 도수의 수면부근에서 형성되는 롤러 형태의 와류가 이러한 에너지 소산의 대부분을 유발한다. 이 연구에서는 여수로에서 발생하는 수중 도수 현상을 고해상도 3차원 수치모의를 통해서 재현하고 실험실에서 PIV를 이용해서 관측한 실험결과와 비교분석 한다. 아울러 수치모의 결과는 수중의 바닥면을 따라 발생하는 ?의 내부와 외부 전단층 그리고 도수에 의해서 발생하는 제순한 와류의 동적 거동 특성을 제시한다.

  • PDF

산업용 폭약을 이용한 폭발용접, 폭발성형과 충격분말고화에 관한 실험 및 수치해석적 연구 (Experimental and Numerical Studies on Application of Industrial Explosives to Explosive Welding, Explosive Forming, Shock Powder Consolidation)

  • 김영국;강성승;조상호
    • 터널과지하공간
    • /
    • 제22권1호
    • /
    • pp.69-76
    • /
    • 2012
  • 본 논문은 폭약의 폭발현상을 이용한 폭발용접, 폭발성형과 충격분말고화기술의 기본적 원리와 실험방법, 실험결과에 대하여 기술한다. 타이타늄(Ti)과 스테인레스 강(Stainless steel, SUS 304) 판재의 폭발용접 실험결과, 두 재료 접촉면의 단면에서는 연속적인 젯(jet)모양의 파형이 관찰되었고, 두 금속판재의 설치 경사각도가 $15{\sim}20^{\circ}$ 이고 접착속도가 2,100~2,800 m/s인 경우에 최적의 접합조건을 보였다. 알루미늄(Al) 판재를 이용한 폭발성형 실험과 전형적인 가압성형 실험 결과를 비교분석하여, 폭발성형의 경우가 큰 곡률변형을 보여 가공성이 우수한 것으로 확인되었다. 끝으로 금속과 세라믹의 혼합분말($Fe_{11.2}La_2O_3Co_{0.7}Si_{1.1}$)에 대한 충격고화 실험법을 제안하고 실험을 수행한 결과, 고화체의 표면과 내부에 균열이 확인되지 않았으며 세라믹입자와 금속입자들의 강한 미세조직 결합이 형성되었다. 또한 충격분말고화실험에서 발생되는 폭약의 폭발에 의한 폭굉파와 수중 충격파의 전파 및 간섭현상을 분석하기 위하여 LS-Dyna 3D를 이용한 동적해석을 수행하였다. 그 결과, 물용기 내 벽면에서 반사된 수중충격파가 중앙부에서 중첩되어 폭약의 폭발압력보다 높은 20 GPa의 수중 충격압을 보여, 물용기 내부형상의 중요성을 입증하였다.

경사면(傾斜面)에 충돌(衝突) 하는 수분류(水噴流)의 열전달(熱傳達) 특성(特性)에 관(關)한 연구(硏究) (Heat Transfer Characteristics of Water Jet Impinging on Oblique Surface)

  • 최국광;나기대;김은영;전성택;이종수
    • 태양에너지
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 1993
  • 하향(下向)의 축대칭자유분류(軸對稱自由噴流)가 등열유속(等熱流束) 조건(條件)의 경사전열면(傾斜傳熱面)에 충돌(衝突)하는 축대칭(軸對稱) 충돌수분류계(衝突水噴流系)를 구성(構成)하였다. 실험변수(實驗變數)로는 노즐-전열면간 거리(距離), 레이놀즈수, 무차원경사각(無次元傾斜角)으로 하였으며, 노즐-전열면간 거리의 범위는 $1.5{\sim}10.5$, 레이놀즈수의 범위(範圍)는 $1{\times}10^4{\sim}4{\times}10^4$, 무차원 경사각의 범위는 0.5, 0.67, 0.83, 1.00으로 하였다. 이와같은 실험적(實驗的) 연구(硏究)에서 국소누셀트수는 $Re^{0.7}$에 비례(比例)하여 증가(增加)되었으며 또한 정체점(停滯點)으로부터 국소거리(局所距離)가 8배(培)되는 하향구배전열면(下向句配傳熱面)의 국소위치(局所位置)에 제2(第)의 극대(極大) 열전달(熱傳達) 현상(現像)이 나타났다. 국소누셀트수는 분류속도가 저속(低速)의 경우 전열면(傳熱面)의 경사각의 영향이 작게 나타나고 있으나, 고속영역(高速領域)이 됨에 따라 경사각의 영향이 증가(增加)되었으며, 특히 국소위치의 $X/D{\leq}4$는 벽면분류영역(壁面噴流領域)에서 경사각에 대한 영향이 명확(明確)하게 나타나고 있다. 정체점열전달(停滯點熱傳達)은 분류속도(噴流速度)와 노즐-전열면간 거리에 비례(比例)해서 증가(增加)되며 층류이론해(層流理論解)에 비(比)하여 최소(最少) 2.4배(培) 이상 높은 열전달효과(熱傳達效果)를 나타내었으며, 정체점(停滯點)누셀트수는 레이놀즈수, 프란틀수, 노즐-전열면간 거리 그리고 무차원(無次元) 경사각(傾斜角)을 포함(包含)하는 무차원(無次元) 실험식(實驗式)으로 나타내었다.

  • PDF

淸州 및 報恩地方의 頭首工洪水災害에 關한 調査硏究(II) -災害原因 및 對策方案을 中心으로- (A Study on the Damages of Head Works by the Storm Flood in the Area of Cheong Ju and Boeun -Emphasis onFactors Influenced on the Disasters and their Countermeasures-)

  • 남성우;김철기
    • 한국농공학회지
    • /
    • 제24권2호
    • /
    • pp.49-55
    • /
    • 1982
  • The purpose of this study is to classify the factors influenced on the damages of head works suffered from the storm flood occurred on July 22 1980 in both Musim and Bochong rivers and to find out an integral counter measures against the causes influenced on the disaster of head works in the engineering aspect of planning, design, construction and maintenance. In this survey, number of samples was taken 25 head Works, and the counter measures against the causes of their disasters summarized was as follows, 1. In the aspect of planning a. As the flood water level after the establishment of head works is more increased than the level before setting of head works owing to having more gentle slope of river bed between the head works than nature slope of river bed. Number of head works should be reduced for the appropriate annexation of them b. In the place where head works is established on the curved point of levee, the destruction of levee becomes severe by the strong deflective current. Therefore the setting of head works on the curved point should be kept off as long as possible and in case of unavoidable circumstances the construction method such as reinforced concrete wall or stone wall filed with concrete and anchored bank revetments should be considered. 2. In the aspect of design a. As scoring phenomena at up stream is serious around the weir Where the concentration of strong current is present in such a place, up stream apron having impermeability should be designed to resist and prevent scoring. b. As the length of apron and protected bed is too short to prevent scoring as down stream bed, the design length should be taken somewhat more than the calculated value, but in the case the calculated length becomes too long to be profitable, a device of water cushion should be considered. c. The structure of protected river bed should be improved to make stone mesh bags fixed to apron and to have vinyl mattress laid on river bed together with the improvement for increasing the stability of stone mesh bags and preventing the sucked sand from the river bed. d. As the shortage of cut-off length, especialy in case of the cutoffs conneting both shore sides of river makes the cause of destruction of embankment and weir body, the culculation of cut-off length should be taken enough length based on seepage length. 3. In the aspect of design and constructions a. The overturing destruction of weir by piping action was based on the jet water through cracks at the construction and expansion joints. therefore the expansion joint should be designed and constructed with the insertion of water proof plate and asphalt filling, and the construction joint, with concaved shape structure and steel reinforcement. b. As the wrong design and construction of the weep holes on apron will cause water piping and weir destruction, the design and construction of filter based on the rule of filter should be kept for weep holes. c. The wrong design and construction of bank revetment caused the severe destruction of levee and weir body resulting from scoring and impulse by strong current and formation of water route behind the revetment. Therefore bank revetment should be designod and constructed with stone wall filled with concrete and anchored, or reinforced concrete wall to prevent the formation of water flow route behind the wall and to resist against the scoring and impulse of strong stream. 4. In the aspect of maintenance When the damaged parts occurred at head works the authorities and farmers concerned should find and mend them as soon as possible with mutual cooperation, and on the other hand public citizen should be guided for good use of public property.

  • PDF

정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성 (Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow)

  • 이홍철;김철생;박복춘;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 실험연구에서는 정상유동상태에서 새롭게 설계된 자가팽창성 그래프트 스텐트의 수력학적 성능을 평가하고자 하였다. 코팅 재질이 다른 두 개의 그래프트 스텐트와 한 개의 타이티놀 금속스텐트가 실험에 사용되었으며, 유량이 가자 5, 10, 15 1/min에서 스텐트 전후에서의 압력변화 및 속도분포를 측정하였다. 스텐트 삽입에 의한 압력손실은 유량이 증가함에 지수적으로 증가하였다. 특히 15 1/min의 유량에서 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트의 압력손실은 거의 동일하나 PU 그래프트 스텐트는 약 6배 이상의 현저한 증가를 보이고 있다. 스텐트 후류에서의 속도분포는 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트는 유량에 관계없이 유사한 형태를 보여주고 있다. 그러나, PU 그래프트 스텐트에서는 특히 유량이 10 1/min 이상에서 속도분포가 비대칭적이고 관 중심에서의 상대적인 낮은 유속을 보여주고 있으며, 결과적으로 벽면전단응력 및 수직응력의 증가론 초래하고 있다. 이와같이 PU 그래프트 스텐트의 상대적으로 낮은 수력학적 성능은 스텐트가 보다 작은 관에 삽입되었을때 코팅재질의 낮은 유연성으로 인하여 스텐트의 표면에 주름이 발생하여 유동단면이 비대칭적으로 되고 벽면의 조도가 증가하며, 관벽과 스텐트와 틈새가 존재하여 제트류가 형성되기 때문으로 해석된다.

이동식 정류장치를 이용한 횡류식 침전지 침전효율 개선 연구 (Improvement of Rectangle Sedimentation basin using the Moving Baffle)

  • 조영만
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.726-731
    • /
    • 2005
  • 장방형 횡류식 침전지는 정수 공정에서 일반적으로 활용되고 있는 침전지 형태로 정수공정 전체에서 탁질 제거 비중이 가장 큰 매우 중요한 공정이다. 횡류식침전지는 유입탁도, 수온 등의 변화에 의해 단락류와 밀도류가 발생하게 되는데 이런 문제점을 해결하기 위해 지내 정류벽을 설치하는 방안이 제안되기도 했지만 정류공에서 발생되는 제트류 등의 문제로 인해 실제 적용사례는 없는 실정이다. 본 연구는 침전지의 전단면에 수류가 일정하게 흐르도록 유도할 수 있는 이동식정류장치에 관한 연구이다. 이동식 정류장치는 부드러운 천 재질의 정류벽이 침전지 전단면에 거쳐 수류의 흐름과 동일한 속도로 이동하면서 침전지내에서 발생될 수 있는 밀도류와 단락류를 조절하여 침전지내 수류 흐름을 전단면에서 일정하게 유도하는 장치이다. 이동식 정류장치를 가동한 결과 침전지 체류시간이 1시간 연장되는 효과를 나타냈다. 즉 다시 말해 염소 이온 최고농도 유출시간이 100분에서 160분으로 연장되었다. 탁도 제거율 시험은 원수 탁도와 체류시간 변화에 따라 연속식과 회분식으로 각각 시험하였다. 탁도 개선율은 연속 운전 방식에서 36%, 회분식 운전 방식에서 58%를 각각 나타냈다. 따라서 장방형 횡류식 침전지에 본 연구에서 제안한 이동식 정류장치를 도입할 경우 30% 이상 탁도 개선이 가능할 것으로 판단된다.

3성분계 인화성 혼합가스의 MESG에 관한 연구 (A Study on the MESG of Flammable Ternary Gas Mixtures)

  • 황경용;변정환;이규남;이택기
    • 한국가스학회지
    • /
    • 제20권3호
    • /
    • pp.30-37
    • /
    • 2016
  • 내압 방폭전기기계 기구는 인화성 가스가 존재하는 위험장소에서 사용되어도 인화성 가스의 점화원이 되지 않는 구조로 이루어져야 한다. 또한 전기 스파크를 발생시키는 부품이 점화원이 되어 기계 기구 내부에서 폭발 시 최대 압력에 견디고 내부 화염이 외부로 전파되어 가스나 증기 폭발을 일으키지 않도록 설계되어야 한다. 본 연구에서는 화염 틈새를 통해 외부로 분사되는 연소 생성물의 분사가 외부 가스나 증기를 점화시킬 정도의 온도나 에너지를 가질 수 없도록 하는 MESG(Maximum Experimental Safe Gap)의 중요한 물리적인 메커니즘에 대해 규명하였다. IEC 60079-20-1:2010 기준에 의해 프로판- 아세틸렌-공기로 이루어진 3성분계 혼합가스의 MESG를 실험하여 MESG 값을 측정하고 가스 폭발시의 최대 폭발압력을 측정하였다. 결과로는 아세틸렌 가스 보다는 폭발력이 낮은 프로판 가스의 조성이 MESG 값과 폭발압력에 더욱 큰 변수로 작용함을 알 수 있었다.

초음속 주유동 환경에서의 막냉각 특성 시험 연구 (An Experimental Study of Film Cooling Characteristics at Supersonic Free Stream Conditions)

  • 김만식;이동민
    • 한국항공우주학회지
    • /
    • 제45권4호
    • /
    • pp.342-348
    • /
    • 2017
  • 본 연구에서는 초음속 주유동 환경에서의 막냉각 특성에 대해 적외선 열상법을 적용한 시험을 수행하였다. 막냉각 시험은 수축형 막냉각 노즐을 갖는 쐐기형 막냉각 시편을 이용해 마하수 3.0, 단위 길이 당 레이놀즈수 $42.53{\times}10^6$$69.35{\times}10^6$ 인 조건을 구현한 자유-제트 시험 설비에서 수행하였다. 모사 탐색창에 해당하는 PEEK의 표면 온도를 계측하여 막냉각 효율을 산출하였고 받음각 및 분사율이 막냉각 효율에 미치는 영향을 분석하였다. 막냉각을 적용하지 않는 경우와 비교할 때, 막냉각을 적용할 경우 측정된 PEEK의 표면 온도가 크게 감소하였다. 막냉각의 유용성은 시간에 따른 PEEK의 표면 온도로부터 산출한 열유속 특성으로도 확인할 수 있다. 분사율이 증가할수록 보호되는 PEEK의 영역이 주유동과 막냉각 유동의 흐름 방향으로 확장되었다.