• Title/Summary/Keyword: Wall Element

Search Result 1,249, Processing Time 0.028 seconds

Effects of freezing and thawing on retaining wall with changes in groundwater level

  • Kim, Garam;Kim, Incheol;Yun, Tae Sup;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.24 no.6
    • /
    • pp.531-543
    • /
    • 2021
  • Freezing and thawing of pore water within backfill can affect the stability of retaining wall as the phase change of pore water causes changes in the mechanical characteristics of backfill material. In this study, the effects of freezing and thawing on the mechanical performance of retaining wall with granular backfill were investigated for various temperature and groundwater level (GWL) conditions. The thermal and mechanical finite element analyses were performed by assigning the coefficient of lateral earth pressure according to phase change of soil for at-rest, active and passive stress states. For the at-rest condition, the mobilized lateral stress and overturning moment changed markedly during freezing and thawing. Active-state displacements for the thawed condition were larger than for the unfrozen condition whereas the effect of freezing and thawing was small for the passive condition. GWL affected significantly the lateral force and overturning moment (Mo) acting on the wall during freezing and thawing, indicating that the reduction of safety margin and wall collapse due to freezing and thawing can occur in sudden, unexpected patterns. The beneficial effect of an insulation layer between the retaining wall and the backfill in reducing the heat conduction from the wall face was also investigated and presented.

Evaluation of the Burst Pressure for Rectangular Wall-thinning of CANDU Feeder Pipe (사각 감육을 고려한 중수로 공급자관 파열압력 평가)

  • Kwang Soo Kim;Min Kyu Kim;Doo Ho Cho;Jae Joon Jeong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.28-35
    • /
    • 2021
  • The flow accelerated corrosion (FAC) is one of significant aging and degradation mechanism and can affect structural integrity of CANDU feeder pipes. Pipe burst can occur under normal operation pressure (min. 10 MPa) if wall-thinning of the feeder pipe due to FAC is accumulated. Previous studies considered simple shapes of feeder pipe with local wall-thinning in order to conservatively assess structural integrity of wall-thinned feeder pipe. In this paper, a new FE model is developed, having an actual shape of the feeder pipe (double bent) as well as the actual wall-thinning shape and location based on the in-service inspection result. Then, the burst pressure assessment of the wall-thinned feeder pipe is performed using lower bound limit load analysis considering elastic-perfectly plastic material. In addition, an improved formulation to predict the burst pressure of the wall-thinned feeder pipe is presented and the safety margin is compared with an existing assessment method.

Empirical evaluations for predicting the damage of FRC wall subjected to close-in explosions

  • Duc-Kien Thai;Thai-Hoan Pham;Duy-Liem Nguyen;Tran Minh Tu;Phan Van Tien
    • Steel and Composite Structures
    • /
    • v.49 no.1
    • /
    • pp.65-79
    • /
    • 2023
  • This paper presents a development of empirical evaluations, which can be used to evaluate the damage of fiber-reinforced concrete composites (FRC) wall subjected to close-in blast loads. For this development, a combined application of numerical simulation and machine learning approaches are employed. First, finite element modeling of FRC wall under blast loading is developed and verified using experimental data. Numerical analyses are then carried out to investigate the dynamic behavior of the FRC wall under blast loading. In addition, a data set of 384 samples on the damage of FRC wall due to blast loads is then produced in order to develop machine learning models. Second, three robust machine learning models of Random Forest (RF), Support Vector Machine (SVM), and Extreme Gradient Boosting (XGBoost) are employed to propose empirical evaluations for predicting the damage of FRC wall. The proposed empirical evaluations are very useful for practical evaluation and design of FRC wall subjected to blast loads.

Seismic Performance of Special Shear Wall Structural System with Effectively Reduced Reinforcement Detail (완화된 단부 배근상세를 갖는 특수전단벽 구조시스템의 내진성능평가)

  • Chun, Young-Soo;Lee, Ki-Hak;Lee, Hyo-Won;Park, Young-Eun;Song, Jin-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.271-281
    • /
    • 2013
  • The current seismic design code prescribes that a structural wall should be designed as a special shear wall when the building height is more than 60 m and its seismic design category is classified as D. However, the use of a special shear wall has a negative effect on constructability and economic efficiency. In the present study, the seismic performance of a special shear wall and a special shear wall with relaxed reinforcement detail was evaluated through a cyclic reversal loading test. The specimens were constructed to measure the results of the experimental variable regarding the reinforcement details of the special boundary element. Next, the seismic performances of a special shear wall structural system and that of a special shear wall structural system with relaxed reinforcement detail was evaluated by methods proposed in the FEMA P695. The cyclic reversal loading test results of this study showed that the performance of the shear wall with relaxed reinforcement detail was almost similar to the performance of a special shear wall and has the performance which requested from standard. The results of the seismic evaluation showed that all special shear walls with relaxed reinforcement detail are satisfied with the design code and seismic performance.

Development of Efficient Plate Element Considering Variable Thickness and Nonuniform Pressure (단면과 압력변화를 고려한 효율적인 평판 요소의 개발)

  • 이성우;심규점
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.1-7
    • /
    • 1993
  • Most of wall or plate structures subjected to nonuniform earth or water pressure has variable thickness. These problems were generally solved by models with uniform thickness and pressure. To obtain more accurate and economic solution for this type of problem. efficient isoparametric plate element considering variable thickness and nonuniform pressure were developed. Some example problems demonstrated efficiency of the proposed element.

  • PDF

on Contact Behaviour Characters of High pressure Wearing using Finite Element Analysis (고압용 웨어링의 접촉거동 특성에 대한 유한요소 해석)

  • 최동열;고영배;김청균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.356-363
    • /
    • 2001
  • Piston seal is a device designed to prevent leakage in split connecctions or between relatively moving part. Contact force, critical pressure at which extrusion occurs, leakage rate, fluid film thickness and friction force have been analyzed for some design parameter such as clearance between cylinder wall piston, depth of rectangular groove and pressure of sealed hydraulic fluid. In this paper, we analyze displacement and stress of Wearing by finite element analysis to understand Contact Behaviour Characters.

  • PDF

A Study on the Precipitation Mechanism of Quartz Veins from Sangdong Deposit by Analyses of Vein Texture and Trace Element in Quartz (상동광산 석영맥의 조직 및 석영의 미량원소 분석을 통한 광맥 침전 기작 도출)

  • Youseong Lee;Changyun Park;Yeongkyoo Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.3
    • /
    • pp.239-257
    • /
    • 2023
  • Sangdong deposit, a W-Mo skarn deposit, is located in Taebaeksan mineralized district, hosting vertically developed scheelite-quartz veins that formed at the late ore-forming stage. In this study, we tried to examine the geochemical signatures of ore-forming fluids and vein-forming mechanisms by analyzing the micro-texture of quartz veins and trace element concentrations of quartz. As a result of texture analyses, quartz veins in the hanging wall orebody and the foot wall orebody commonly exhibit the blocky and the elongate blocky texture, respectively, whereas quartz veins in the main orebody show both textures. These textural differences indicate that quartz veins from the hanging wall orebody were precipitated by the primary hydrofracturing due to H2O saturation in the igneous body with relatively high temperature and pressure at a vein-skarn stage, and after that, repeated hydrofracturing caused the formation of quartz veins from the main orebody and foot wall orebody. The results of trace element concentrations show that Li++Al3+↔Si4+ is a main substitution mechanism. However, those of the foot wall orebody were clearly divided into a Li+-dominated substitution and a Na+-, K+-dominated substitution. Considering that quartz veins from the foot wall orebody commonly show the elongate blocky texture, such a distinction means that it is a result of repeated injections of fluid with the different composition. Ti concentrations of quartz from the hanging wall, main, and the foot wall orebody are 28.6, 8.2, and 15.7 ppm in average, respectively. Given a proportional relationship between the precipitation temperature and Ti concentrations, it seems that quartz veins from the hanging wall orebody were precipitated at the highest temperature. Al concentrations of the hanging wall, main, and the foot wall orebody having an inverse relationship with fluid pH are 162.3, 114.2, and 182.5 ppm in average, respectively. These results show that Al concentrations in vein-forming fluids were not changed dramatically. Moreover, these concentrations are extremely low in comparison with the other hydrothermal deposits. This indicates that quartz in overall ore veins at Sangdong deposit was precipitated from the constant condition with slightly acidic to near neutral pH.

The Effects of Nail Inclination in Soil Nailing by Finite Element Analysis (유한요소해석에 의한 쏘일네일링의 네일 경사각의 영향에 관한 연구)

  • 천병식;김원철;윤창기
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.19-27
    • /
    • 2004
  • Since the first construction of soil nailing in France in 1972, the application of soil nailing has increased. However, there is currently no design method which is universally accepted or agreed upon far soil nailed wall, because each of the design methods has different assumptions and, therefore, different approaches, moreover, since the suggested optimal inclination angles of nails are different by researchers. Therefore, the effect of nail inclination with soil nailing is analyzed by FEM. In this study, Finite element program SOILSTRUCT was applied for the effect analysis of nail inclination in soil nailed wall. For this finite element analysis, CEBTP No. 1 project data were used. The analyzed nail inclination ranged from 0$^{\circ}$ to 30$^{\circ}$ with 5$^{\circ}$ intervals. The result of finite element analysis showed that the most optimal inclination was 20$^{\circ}$ Also, the tension farce in the nails increased as the nail inclination increased. However, the effect of nail inclination on the wall deformation was very little. Therefore, constructability seems to be more important than nail inclination. Also, the tension force in the nails increases as the nail depth below the top of the wall increases, except f3r the lowest nail. Therefore, appropriate nail diameter should be used to prevent breakage of nails with considering nail strength-deformation interaction.

A Study on the Development and Application of Movable Partition Components for Facilitating of Long-life Housing (장수명 주택의 활성화를 위한 가동칸막이벽체 개발현황 연구)

  • Lee, Sung-Ok;Kim, Soo-Am
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.91-98
    • /
    • 2010
  • The purpose of this study is to develop the feasibility of movable partition wall components that are able to correspond changes of structure system and spatial configuration by the needs of residents for the activation of long-life housing. The key element of various movable partition wall components, a movable partition wall, was analyzed for problems through both as-is analysis and field installation in Korea and Japan, and then its feasibility was verified. The movable partition wall can break the uniformity of a fixed one, can integrate and separate limited space by changes in the demands of residents, can be easy to separate, and can be independent. The development of the movable partition wall is important for the realization of diverse residential space, ease of remodeling, environment adaptation, promotion of modularization, etc. It is comprised of surfacing materials, core materials, structural materials, and movable parts. The domestic movable partition wall was verified regarding the feasibility of an apartment house through on-site inspections and sound insulation tests by KOHP21, KICT. In conclusion, the construction of long-life housing that has sustainable values in the use of housing is nationally an important assignment, so as to secure good housing stock.

Control Performance of Friction Dampers Using Flexural Behavior of RC Shear Wall System (전단벽식 구조의 휨거동을 이용한 마찰감쇠기의 제어성능)

  • Chung, Hee-San;Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won;Byeon, Ji-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.856-863
    • /
    • 2008
  • High-rise apartments of shear wall system are governed by flexural behavior like a cantilever beam. Installation of the damper-brace system in a structure governed by flexural behavior is not suitable. Because of relatively high lateral stiffness of the shear wall, a load is not concentrate on the brace and the brace cannot perform a role as a damping device. In this paper, a friction damper applying flexibility of shear wall is proposed in order to reduce the deformation of a structure. To evaluate performance of the proposed friction damper, nonlinear time history analysis is executed by SeismoStruct analysis program and MVLEM(multi vertical linear element model) be used for simulating flexural behavior of the shear wall. It is found that control performance of the proposed friction damper is superior to one of a coupled wall with rigid beam. In conclusion, this study verified that the optimal control performance of the proposed friction damper is equal to 45 % of the maximum shear force inducing in middle-floor beam with rigid beam.