• Title/Summary/Keyword: WAMS

Search Result 19, Processing Time 0.082 seconds

Optimal WAMS Configuration in Nordic Power System

  • Mohamed A.M. Hassan;Omar H. Abdalla;Hady H. Fayek;Aisha H.A. Hashim;Siti Fauziah Toha
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.3
    • /
    • pp.130-138
    • /
    • 2023
  • The Smart grids are considered as multi-disciplinary power systems where the communication networks are highly employed. This paper presents optimal wide area measurement system (WAMS) configuration in Nordic power system. The transition from SCADA to WAMS becomes now trend in all power systems to ensure higher reliability and data visibility. The optimization applied in this research considered the geographical regions of the Nordic power system. The research considered all the devices of WAMS namely phasor measurement units (PMUs), phasor data concentrators (PDCs) and communication links. The study also presents two scenarios for optimal WAMS namely base case and N-1 contingency as different operating conditions. The result of this research presents technical and financial results for WAMS configuration in a real power system. The optimization results are performed using MATLAB 2017a software application.

Development of "K-WAMS" Wide Area Monitoring System based on Synchro-Phasor (시간 동기 데이터를 이용한 광역계통 감시시스템 "K-WAMS"구현)

  • Kim, Sang-Tae;Kim, Ji-Young;Lee, Dong-Chul;Song, Wan-Suk;Jang, Su-Hyung;Kim, Young-Don
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.44-46
    • /
    • 2008
  • K-WAMS based on i-PIU as a synchro-phasor data acquisition device using GPS can treat a monitoring and evaluation of wide area power system to detect a various symptoms of wide area disturbances and prevent large blackout. This paper introduced the development of K-WAMS such like WAMS(Wide Area Monitoring System).

  • PDF

Building and Actual Proving K-WAMS in Korea Power Grid (광역 전력계통 감시시스템 구축 및 실증)

  • Kim, Sang-Tae;Kim, Ji-Young;Song, Wan-Seok;Jang, Su-Hyung;Moon, Young-Hwan;Kim, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.175_176
    • /
    • 2009
  • K-WAMS based on i-PIU as a synchro-phasor data acquisition device using GPS can treat a monitoring and evaluation of wide area power system to detect a various symptoms of wide area disturbances and prevent large blackout. This paper introduced the development of K-WAMS such as WAMS(Wide Area Monitoring System).

  • PDF

A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop (발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구)

  • Kim, Hak-Man;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

A novel technology of Establishing Intelligent Power Information System based on Multi-Agent (멀티에이전트 기반의 지능형 전력 정보시스템 구축 기술)

  • Kim, Ji-Young;Kim, Sang-Tae;Yu, Nam-Cheol;Lee, Dong-Cheol
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.307-312
    • /
    • 2008
  • 최근 전기 전력 도메인의 IT화 (전력 IT) 가 본격적으로 진행되면서 전기 데이터를 취득하기 위한 기기들 뿐만 아니라 전력 운영 환경이 변화를 도모하고 있다 본 논문에서는 이런 전력 IT 의 일환으로 개발된 지능형 전력 정보 모니터링 시스템 (K-WAMS)을 소개하고자 한다. 이 시스템은 이기종 분산 환경에서 전력 정보를 실시간으로 전송 받아 현재 전력계통의 상황을 직관적으로 판단할 수 있는 정보를 제공하여 광역 정전을 예방하고자 하는 조기경보시스템 (Early Warning System) 이다. 또한, 전력계통의 안정성 여부를 판단하는 지능형 에이전트의 구현을 통해 광역 정전을 예견하는 지수를 제공하고, 실시간 데이터 처리 및 이력 데이터 저장 에이전트들을 통해 현재 취득되고 있는 현장 데이터 모니터링 기능을 제공한다. K-WAMS 는 실시간으로 전송 처리되는 고속 대용량 데이터들의 처리 지연, 동적 환경으로 인한 네트워크의 부하문제를 해결하기 위해서 IPC Shared Memory 기법을 이용하였고, 동적 프로세스들의 작업 스케줄링을 관리하기 위한 IPC Message Queue 기법을 이용하였다. 또한 논리적 기능 기반으로 설계된 현재 중앙 급전소(GCC) 단위의 설계 모델은 향후 지역 급전소(RCC) 단위로 설치 될 경우 재사용 되어 개발 생산성을 향상시킬 것으로 예상된다.

  • PDF

Initial Results of Low Frequency Oscillation Analysis based on Synchrophasor in KEPCO System (Synchrophasor를 이용한 한전계통의 저주파 진동 해석 초기 결과)

  • Shim, Kwan-Shik;Kim, Sang-Tae;Nam, Hae-Kon;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • The parameters of electromechanical modes offer considerable insight into the dynamic stability properties of a power system. This paper describes an initial result for extraction of dynamic parameters from synchrophasor measurements collected on the KEPCO system. Dominant modes of the system are estimated by oscillation detecting program in K-WAMS. The critical wide-area modes of KEPCO system have frequencies in the 0.4 to 0.7Hz range. And the local mode causing the low frequency oscillation of generators located on the west coast area has in the frequency 0.97 and 1.25 Hz, respectively. This results can serve as a reference in the future for reliable system operation in KEPCO system.

Review on Occupational Exposure To Asbestos in Korea (우리나라 석면 취급 산업장 석면 농도에 대한 고찰)

  • Park, Donguk;Choi, Sangjun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.307-320
    • /
    • 2009
  • This study was conducted not only to review airborne asbestos levels reported in workplaces in Korea, but also to analyze their levels according to various characteristics All asbestos concentration reported as either geometric mean (GM) and geometric standard deviation (GSD) or ranges were transformed to arithmetic mean to estimate exposure level. In addition, weighted arithmetic means (WAMs) were calculated to weigh asbestos levels based on the different number of samples. Differences of asbestos levels among several characteristics such as industry type, decade, operation and sampling and analytical methods were analyzed using analysis of variance (ANOVA). The number of articles studying asbestos levels from workplaces was found to be 9 including two report types. Five of those were reported prior to 1990s and rest of them after 1990s. Only several industries such as asbestos textile, asbestos cement, brake-lining repair shops were studied, while various industries using asbestos or asbestos containing materials (ACMs) were not studied. ANOVA found that asbestos exposure levels (WAM = 5.26f/cc) reported from textile industry were significantly higher than those from other industries (cement = 0.63f/cc, brake-lining = 0.2f/cc - 0.47f/cc) (p < 0.0001). Average exposure levels studied prior to the 1990s (3.13f/cc) were found to be significantly higher than that (0.86f/cc) after the 1990s (p<0.0001). All WAMs reported until the 1994 were found to be higher than the current occupational exposure limits (0.1f/cc). This study recommends that retrospective exposure to asbestos based on various industry types and operations should be assessed.

Hierarchical Infra Design Strategy for WAMAC System based on Synchro-Phasor Data (WAMAC 시스템을 위한 계층적 인프라 설계 기법)

  • Kim, Ji-Young;Kim, Jin-Hwan;Kim, Sang-Tae;Cho, Jun-Hee;Choi, Mi-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.302-303
    • /
    • 2011
  • Smart WAMAC (Wide Area Monitoring And Control) System, which supplements control function with the function of WAMS(Wide Area Monitoring System), is an intelligent system not only monitoring the wide area but controlling the power equipment according to defined procedure. This paper presents WAMAC system architecture for hierarchical Infra and considerations to design and implement.

  • PDF

Spectral Analysis of LFO Using Synchrophasor in KEPCO Systems (Synchrophasor를 이용한 한전계통의 저주파 진동 스펙트럴 해석)

  • Shim, Kwan-Shik;Choi, Jun-Ho;Kim, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.63-73
    • /
    • 2013
  • The parameters of electromechanical modes offer considerable insight into the dynamic stability properties of a power system. This paper presents a results of a LFO(low-frequency oscillation) based on the time-synchronized signals measured by synchrophasor in the rolling blackout. Spectral analysis was performed, and critical parameters were estimated using the data acquired from synchrophasors installed in the KEPCO system. As significant modes, a 0.68 Hz oscillation mode that occurred prior to the forced load shedding in the rolling blackout was estimated. Such an oscillation mode can cause an uncontrollable blackout. Therefore, the system should be operated so that significant oscillation modes are not activated. This results can serve as a reference in the future for reliable system operation in the event of a similar blackout.

Design & Development of System Architecture for Wide Area Defense System (광역정전 Defense를 위한 System Architecture 설계 및 개발)

  • Kim, S.-Tae;Lee, Jeong-Hyun;Kim, Ji-Young;Lee, Dong-Chul;Moon, Young-Hwan;Kim, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.165-166
    • /
    • 2006
  • Recently, after Wide Area Outage of the North-Eastern United States occurred, many countries started to be concerned about WAMS (Wide Area Monitoring System), and Korean power system also experienced Wide Area outage according to typhoon Mae-Mi, and Haenam-Jeju HVDC line fault. Since it is too difficult to detect a symptom based on SCADA or EMS, a defense system of electric power infrastructure has required. In this research, the designed and developed system processes the time synchronized real time power system information based on GPS and shows the 2D/3D monitoring viewer using the phasor data and the results of three algorithms.

  • PDF