• Title/Summary/Keyword: W-W Test

Search Result 4,640, Processing Time 0.041 seconds

Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test (PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Park, Chi-Hong;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Validation of a 750 kW semi-submersible floating offshore wind turbine numerical model with model test data, part I: Model-I

  • Pham, Thanh Dam;Shin, Hyunkyoung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.980-992
    • /
    • 2019
  • This paper describes a model test and numerical simulation of a 750-kW-semi-submersible platform wind turbine under several wind and wave conditions for validation of the numerical simulation model. The semi-submersible platform was designed to support the 750-kW-wind turbine class and operate at a water depth of 50 m. The model tests were performed to estimate the performance characteristics of the wind turbine system in the wide tank of the University of Ulsan. Motions and loads of the wind turbine system under the wind and wave conditions were measured and analyzed. The NREL-FAST code was used to simulate the wind turbine system, and the results were compared with those of the test model. The results demonstrate that the numerical simulation captures noticeably the fully coupled floating wind turbine dynamic responses. Also, the model shows a good stability and small responses during waves, wind, and operation of the 750-kW-floating offshore wind turbine.

A Study on the Change in the Results of the Straight Leg Raising Test according to the Intensity of Microwave Diathermy

  • Jong Ho Kang;Tae Sung Park
    • The Journal of Korean Physical Therapy
    • /
    • v.36 no.1
    • /
    • pp.9-13
    • /
    • 2024
  • Purpose: Although microwave diathermy is widely employed, research conducted in South Korea indicates a lack of theoretical understanding concerning the appropriate application intensity. Consequently, there is a need to enhance the objectivity of microwave diathermy by conducting quantitative studies to determine its effective application intensity and provide suitable application parameters. Methods: The study was performed on 60 participants, divided equally into 40W or 80W microwave diathermy intervention groups. Microwave diathermy was applied at 2,450MHz to iliocostalis and longissimus muscles for 15 minutes in each group. Ranges of motion were compared before and after intervention using straight leg raise (SLR) test results. The analysis was performed using the paired t-test and the independent t-test. Results: SLR angles increased significantly in both groups after intervention, but the 80W group exhibited a greater post-intervention angle increase. While no significant intergroup difference was observed between pre-intervention angles, post-intervention angles were significantly different. Conclusion: The study confirms that microwave diathermy treatment at 40W for 15 minutes effectively increases SLR angles but that treatment at 80W has a greater effect. Further research is warranted to establish quantitatively the optimal time and intensity settings for microwave diathermy.

Development of Integrated Test Equipment for Airborne SAR System and Control Unit (항공탑재 SAR 시스템 및 통제장치 시험을 위한 통합시험장비 개발)

  • Lee, Hyon-Ik;Hwang, Tae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.747-754
    • /
    • 2013
  • This paper describes SCTE(System and Control unit Test Equipment) as an integrated test equipment for airborne SAR system and control unit. SCTE enhances reusability of test equipment by modular design for required functions and strengthens automatic testing and test convenience by providing functions such as script-based testing function and report generation function. Also, it includes a navigation data simulator which can simulate various flight conditions. In this paper, we details SCTE requirements, H/W and S/W design, implementation, and test results with control unit and SAR system.

Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module (PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Anxiolytic effect of leaf galls extracts of Pipernigrum Linn. in Swiss Albino mice

  • Rajesh, R;Sathiyanarayanan, L;Arulmozhi, S;Ruby, Ruby
    • Advances in Traditional Medicine
    • /
    • v.9 no.2
    • /
    • pp.142-148
    • /
    • 2009
  • Anxiety disorders are one of the serious problems which need proper therapy devoid of side effects of presently available medicines. The present study evaluates the anxiolytic and sedative activity of leaf galls of Piper nigrum Linn. in Swiss Albino mice. The pet. ether, chloroform, ethyl acetate and ethanol extracts of leaf galls of Piper nigrum Linn were obtained by continuous soxhlet extraction. The prepared extracts were found to be safe up to 2000 mg/kg body weight of mice in the acute toxicity study. Each extract was assessed for anxiolytic activity in Swiss Albino mice by elevated plus Maze, open field test, rota rod test and phenobarbitone induced sleeping time test. In the Elevated Plus Maze test, the pet.ether extract and chloroform extract at a dose of 50 mg/kg b.w. orally, significantly (P < 0.01) increased the number of entries and time spent in open arm comparable with standard diazepam at the dose of 10 mg/kg. b.w. p.o. In the open field test, pet. ether extract (50 mg/kg b.w. p.o.) showed significant increase (P < 0.01) in ambulation and activity in the center. Chloroform extract (50 mg/kg b.w p.o.) was significant (P < 0.05) for both ambulation and center activity. Pet. ether extract (50 mg/kg b.w. p.o) also showed significant activity (P < 0.01) in rota rod test. All the results are comparable with standard diazepam at the dose of 1 mg /kg b.w, p.o. Moreover all the extracts showed significant (P < 0.01) increase in the phenobarbitone induced sleeping time among which pet.ether showed more prominent activity (36%) comparable with control. The results revealed that, the active pet.ether extract and chloroform extract of leaf galls of Piper nigrum Linn is worthwhile to develop the bioactive principle for anxiolytic activity.

Effects of the Recycled Waste Rope Fibers on the Strength and Carbonation Resistance of Cementitious Composites (폐로프 재활용 섬유보강 시멘트 복합체의 탄산화가 강도에 미치는 영향)

  • Sanghwan Cho;Taek Hee Han;Min Ook Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.407-415
    • /
    • 2023
  • In this study, a carbonation test was conducted on cementitious composites reinforced with recycled waste rope fibers (W series) according to EN 12390-12 standards. The test results were compared to those of commercially available polypropylene fibers (P series). In the carbonation test, both the carbonation depth and area were significantly influenced by the water-to-cement ratio. Notably, the carbonation resistance performance of cementitious composites containing waste rope fibers surpassed that of commercially available PP fibers under equivalent conditions. Throughout the 250-day test period, the W series exhibited higher compressive strength values than the P series, while both series displayed a similar trend of strength increase during the same duration. During the initial stage, the W series exhibited flexural strength levels similar to those of the P series. However, in the later stages, the P series showed a higher mean flexural strength by 1.0 MPa.

A Study on Performance Requirement of I/Q Impairments for RF Implementation in W-CDMA User Equipment (W-CDMA 사용자장치 RF 구현을 위한 I/Q 열화성능요구규격 연구)

  • Lee, Il-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.148-154
    • /
    • 2005
  • This paper deals with performance degradations caused by RF I/Q impairments such as amplitude mismatch and phase mismatch in W-CDMA user equipment which uses QPSK(Quadrature Phase Shift Keying) modulation. The impacts of I/Q impairments on the BER(Bit Error Rate) are analyzed by using the variations of adjacent symbol distance. The BER versus amplitude mismatch and phase mismatch with QPSK constellation is reviewed through Matlab simulation. Performance degradation produced by RF I/Q impairments is measured with the implemented RF transceiver and modulation/demodulation test equipments through EVM(Error Vector Magnitude). The minimum performance requirements of amplitude mismatch and phase mismatch in W-CDMA user equipment are presented from the point of hardware implementation and the test method of the impairments is also included.