• Title/Summary/Keyword: W/S Ratio

Search Result 1,677, Processing Time 0.033 seconds

Implementation of Ternary Valued Adder and Multiplier Using Current Mode CMOS (전류모드 CMOS에 의한 3치 가산기 및 승산기의 구현)

  • Seong, Hyeon-Kyeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1837-1844
    • /
    • 2009
  • In this paper, the circuit of 2 variable ternary adder and multiplier circuit using current mode CMOS are implemented. The presented ternary adder circuit and multiplier circuit using current mode CMOS are driven the voltage levels. We show the characteristics of operation for these circuits simulated by HSpice. These circuits are simulated under $0.18{\mu}m$ CMOS standard technology, $5{\mu}A$ unit current in $0.54{\mu}m/0.18{\mu}m$ ratio of NMOS length and width, and $0.54{\mu}m/0.18{\mu}m$ ratio of PMOS length and width, and 2.5V VDD voltage, MOS model Level 47 using HSpice. The simulation results show the satisfying current characteristics. The simulation results of current mode ternary adder circuit and multiplier circuit show the propagation delay time $1.2{\mu}s$, operating speed 300KHz, and consumer power 1.08mW.

Three-Dimensional Flow and Aerodynamic Loss in the Tip-Leakage Flow Region of a Turbine Blade with Pressure-Side Winglet and Suction-Side Squealer (압력면윙렛/흡입면스퀼러형 터빈 동익 팁누설영역에서의 3차원유동 및 압력손실)

  • Cheon, Joo Hong;Kang, Dong Bum;Lee, Sang Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.399-406
    • /
    • 2014
  • Three-dimensional flow and aerodynamic loss in the tip-leakage flow region of a turbine blade equipped with both a pressure-side winglet and a suction-side squealer have been measured for the tip gap-to-span ratio of h/s = 1.36%. The suction-side squealer has a fixed height-to-span ratio of $h_s/s$ = 3.75% and the pressure-side winglet has width-to-pitch ratios of w/p = 2.64%, 5.28%, 7.92% and 10.55%. The results are compared with those for a plane tip and for a cavity squealer tip of $h_{ps}/s$ = 3.75%. The present tip delivers lower loss in the passage vortex region but higher loss in the tip-leakage vortex region, compared to the plane tip. With increasing w/p, its mass-averaged loss tends to be reduced. Regardless of w/p, the present tip provides lower loss than the plane tip but higher loss than the cavity squealer tip.

A Study on the Fabrication of Plasma Display Panel and It's Characteristics (플라즈마 디스플레이 판넬의 제작 및 특성 연구)

  • Kim, J.S.;Choi, K.C.;Shin, B.J.;Whang, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.157-160
    • /
    • 1990
  • A dot matrix type DC Plasma Display Panel was fabricated and it's characteristics was investigated. Paschen curve and I-V curve of various gas mixture was given. Optimal gas mixing ratio, pressure and operating point was determined. The priming effect was observed and discharge delay time was measured with varing applied voltage, priming current, priming distance, duty ratio.

  • PDF

Fingernail Configuration

  • Jung, Jin Woo;Kim, Kwang Seog;Shin, Jun Ho;Kwon, Yu Jin;Hwang, Jae Ha;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.42 no.6
    • /
    • pp.753-760
    • /
    • 2015
  • Background A number of conditions can alter a person's fingernail configuration. The ratio between fingernail width and length (W/L) is an important aesthetic criterion, and some underlying diseases can alter the size of the fingernail. Fingernail curvature can be altered by systemic disorders or disorders of the fingernail itself. Although the shape and curvature of the fingernail can provide diagnostic clues for various diseases, few studies have precisely characterized normal fingernail configuration. Methods We measured the W/L ratio of the fingernail, transverse fingernail curvature, hand length, hand breadth, and distal interphalangeal joint width in 300 volunteers with healthy fingernails. We also investigated whether age, sex, height, and handedness influenced the fingernail W/L ratio and transverse fingernail curvature. Results In women, fingernail W/L ratios were similar across all five fingers, and were lower than those in men. The highest value of transverse fingernail curvature was found in the thumb, followed by the index, middle, ring, and little fingers. Handedness and aging influenced transverse fingernail curvature, but not the fingernail W/L ratio. Fingernails were flatter on the dominant hand than on the non-dominant hand. The radius of transverse fingernail curvature increased with age, indicating that fingernails tended to flatten with age. Conclusions Our quantitative data on fingernail configuration can be used as a reference range for diagnosing various diseases and deformities of the fingernail, and for performing reconstructive or aesthetic fingernail surgery.

On Rate of Multi-Hole Injector for Diesel Engine (디이젤 기관용 다공연료 분사 밸브의 분사율 측정)

  • Jeong, Dal-Sun;An, Su-Gil;Gwon, Gi-Rin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • Ifis recommended that the injection rate should be accurate and reliable in the input data of the performance simulation in diesel engine. Matsuoka Sin improved W. Bosch's injection ratio measurement system. Matsuoka Sin reduced length of the test pipe and set the orifice. However, it was not measured accurately to measure the injection ratio due to reflection wave. In the present thesis, the improved measurement system with combination of the conventional W. Bosch type injection ratio measurement system and Matsuoka Sin type corrected W. Bosch type was practically made. The location of orifice and throttle valve was modified and set one more back pressure valve in order to reduce the effect of reflection wave. The results according to injection condition of multi-hole nozzle are following: 1. Measurement error of injection ratio measurement system in this thesis was $\pm$ 1 %, therefore, its reliability was good. 2. The form of injetion ratio is changed from trapezoidal shape to triangle shape with increase of revolution per minute when injection amount is constant. 3. In the case of constant rpm, the initial injection ratio is almost constant regardless of the amount, meanwhile the injection period becomes longer with increase of the amount. 4. The injection pressure of nozzle isn't largely influenced with injection ratio in the case of constant injection amount and rpm, otherwise the initial injection amount is increased by 3-4% when the injection pressure is low. 5. The injection ratio isn't nearly influenced with back pressure.

  • PDF

Experimental analysis on rheological properties for control of concrete extrudability

  • Lee, Hojae;Kim, Jang-Ho Jay;Moon, Jae-Heum;Kim, Won-Woo;Seo, Eun-A
    • Advances in concrete construction
    • /
    • v.9 no.1
    • /
    • pp.93-102
    • /
    • 2020
  • In this study, we examined the relationship among the rheological properties, workability, and extrudability in the construction of concrete structures using additive manufacturing. We altered the component materials (binder type, water-binder (W/B) ratio, sand ratio) to assess their effect on the rheological properties experimentally. The results indicated that the W/B and sand ratios had the largest effect on the rheological properties. In particular, when the sand ratio increased, it indicated that adjusting the sand ratio would facilitate control over the rheological properties. Additionally, we compared the rheological properties with the results of a traditional workability evaluation, namely the table flow test. This indicated the possibility of inferring the rheological properties by using traditional methods. Finally, we evaluated extrusion quantity according to table flow. The extrusion rate was 350 g/s for a flow of 210 mm and 170 g/s for a flow of 130 mm, indicating that extrusion rate increased as flow increased; however, we concluded that a flow standard of approximately 140-160 mm is suitable for controlling the actual extrusion quantity and rate.

The Effect of The Flexural Strength Ratio on Beam-Column Joint with High and Low Strength Concrete (고강도와 보통 강도 콘크리트를 사용한 보-기둥 접합부의 휨강성화에 따른 이력거동)

  • Shin, S.W.;An, J.M.;Moon, J.I.;Kim, D.K.;Lee, K.S.;Park, H.M.;Lee, S.H.;Oh, J.G.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.185-190
    • /
    • 1992
  • ACI318-89 Recommended that when the specified compressive strength of concrete in a column is greater than1.4 times that specified for a floor system, top surface of the column concrete shall extend 2ft(600mm)into the slab from the face of column to avoid unexpected brittle failure. The major variables are extension distance, flexural strength ratio(Mr), and shear reinforcement ratio(Vs). Test results are as follows ; (1) The failure modes of specimens under cyclic loading were concentrated at critical region from beam-column joint face. (2) Ductility index($\mu$f) were increased with increasing of shear confinement ratio and flexural strength ratio. (3)The specimens with 2ft extension distance showed more ductility than the specimens with 1ft extension distance.

  • PDF

The Performance & Operation Analysis of a Steam Reformer for MCFC (MCFC용 Steam Reformer 개질성능 분석 및 운전평가)

  • Seo, Hai-Kung;Koh, Joon-Ho;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.4
    • /
    • pp.149-159
    • /
    • 2000
  • This paper is concerned with the performence of a steam reformer for 25kW class MCFC, which is compared with the theoretically calculated results at various operating conditions. The theoretical $H_2$ production amount and $CH_4$ conversion rate are calculated with variations of temperature and steam/carbon (S/C) ratio using fortran program, and the actual values are measured from flowmeter and gas chromatography. As a result of the comparison of theoretical and actual values, the theoretical $H_2$ production amount is calculated by $24.4m^3/hr$ at the normal operating condition(LNG $9m^3/hr$, S/C ratio 5, absolute pressure $2.77kg/cm^2$, $610^{\circ}C$), but the actual production amount is only $19.4m^3/hr$, which is 79.5% of the theoretical value. Nevertheless, at the normal operating condition, the reformer for 25kW class MCFC performed well for a 2,100 hr long run operation, constantly producing $H_2$.

  • PDF

Fatigue Strength Assessment of TLP Tendon Porch Using API 2W Gr.50 Steel

  • Im, Sung-Woo;Seo, Young-Seok;Lee, Joo-Sung
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.1
    • /
    • pp.25-35
    • /
    • 2007
  • This paper is concerned with the fatigue strength assessment of tendon porch found which is categorized as the special structural member in TLP. Large-scale tendon porch specimens have been designed and fabricated with API 2W Gr.50 steel recently produced by POSCO. Fatigue test has been carried out for three tendon porch specimens under various load level. Fatigue strength has been evaluated based on the nominal stress range and the results are compared with the fatigue design curve of DnV RP-C203. From the present experimental study, it has been found that the porch specimens satisfy the fatigue design rule although test was carried out under the positive stress ratio. It can be, therefore, said that the API 2W steel produced by POSCO possess sufficient fatigue strength.