• Title/Summary/Keyword: Vue

Search Result 37, Processing Time 0.021 seconds

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Dual Select Diode AMLCDs;A Path Towards Scalable Two Mask Array Designs

  • Boer, Willem Den;Smith, G. Scott
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.383-388
    • /
    • 2004
  • In this paper an alternative Active Matrix LCD technology is described with scalable, low cost processing. The Dual Select Diode AMLCD requires 60% lower capital investment in the array process than a-Si TFT arrays and results in 20% lower cost LCD modules. Development at several AMLCD manufacturers is in progress.

  • PDF

Recent Progress in Low Cost Dual-Select-Diode AMLCD Technology

  • Boer, Willem Den;Smith, G. Scott
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.873-877
    • /
    • 2005
  • Recent developments in Dual Select Diode (DSD) AMLCD technology are described. They include a novel array design and drive method with shared select lines, which leads to higher aperture ratio and a further reduction of module cost. A Color-On-Array DSD process and pixel layout compatible with In-Plane-Switching is also proposed.

  • PDF

Comparison of Two Rapid Antigen Detection Tests for Diagnosis of Group A Streptococcal Pharyngotonsillitis (A군 연쇄구균성 인두편도염 진단을 위한 두 종류 신속항원검사법의 비교)

  • Song, Seung Kyu;Hong, Mi Ae;Oh, Kyung Chang;Ahn, Seung In;Tae, Mi Hyon;Shin, Hye Jung;Chang, Jin Keun;Cha, Sung Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.8
    • /
    • pp.973-979
    • /
    • 2002
  • Purpose : Recently, a number of rapid antigen detection tests have been available to diagnose group A streptococcal pharyngotonsillitis. The purpose of this study was to determine the sensitivity, specificity and consistency of the two rapid antigen detection tests. Methods : Among the patients who visited our clinic from November 2001 to February 2002, 61 patients who had clinical findings of pharyngeal erythema or edema, pharyngeal exudates and soft palatine petechiae were enrolled in our study. A total of 61 patients were tested with rapid antigen detection tests and throat culture. BD $LINK2^{TM}$ Strep A(Becton, Dickinson & Company, U.S.A.) and $QuickVue^{(R)}$ $In-Line^{TM}$(Quidel Corporation, U.S.A.) were selected for rapid antigen detection tests. Results : Of the 61 patients tested, 22 patients were confirmed as group A streptococcal pharyngotonsillitis by throat culture. The BD $LINK2^{TM}$ Strep A had a sensitivity of 81.8% and a specificity 89.7%. The positive and negative predictive values were 81.8% and 89.7%, respectively. The $QuickVue^{(R)}$ $In-Line^{TM}$ had a sensitivity of 77.3% and a specificity of 100%. The positive and negative predictive values were 100% and 88.6%, respectively. The kappa values of BD $LINK2^{TM}$ Strep A and $QuickVue^{(R)}$ $In-Line^{TM}$ were 0.72 and 0.81, respectively. Conclusion : In addition to high sensitivity, specificity and consistency, both kits are easy to use and simple to interpret, and therefore have the potential to be used with backup throat culture for diagnosis of acute pharyngotonsillitis.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.

Development of Web Application Service to Football Data Management (축구 데이터 운용 웹 서비스 개발)

  • Cho Kyu Cheol;Lee Hae Chan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.01a
    • /
    • pp.257-260
    • /
    • 2023
  • 본 논문에서는 Vue.js와 Spring Boot 프레임워크를 사용하여 사용자 편의성을 제공하기 위해 Gird System, Data Table, Chart 등의 기능을 활용하여 축구 데이터를 표현한 웹 응용서비스를 개발하였다. Rapid API의 Open REST API 중 하나인 API-FOOTBALL에 액세스하여 국내에서 쉽게 찾아보기 어려운 세계 축구 리그의 순위표, 일정, 팀 및 선수의 세부 정보 데이터를 활용하였다.

  • PDF

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

Clinical Analysis of Influenza in Children and Rapid Antigen Detection Test on First Half of the Year 2004 in Busan (2004 상반기 부산 지역에서 유행한 인플루엔자의 임상 역학적 분석 및 인플루엔자 진단에 있어서의 신속 항원 검사법)

  • Choi, So Young;Lee, Na Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.2
    • /
    • pp.158-169
    • /
    • 2004
  • Purpose : Although influenza is one of the most important cause of acute respiratory tract infections in children, virus isolation is not popular and there are only a few clinical studies on influenza and diagnostic methods. We evaluated the epidemiological and clinical features of influenza in children and rapid antigen detection test(QuickVue influenza test) on fist half of the year 2004 in Busan. Methods : From January 2004 to June 2004, throat swab and nasal secretion were obtained and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Influenza viruses were isolated in 79(17.2%) out of 621 patients examined. Influenza virus was isolated mainly from March to April 2004. The ratio of male and female with influenza virus infection was 1.2 : 1 with median age of 4 years 6month. The most common clinical diagnosis of influenza virus infection was bronchitis. There was no difference between influenza A and B infection in clinical diagnosis and symptoms. All patients recovered without severe complication. The sensitivity obtained for rapid antigen detection test (QuickVue influenza test) was 93.6% and the specificity was 80.2%, the positive predictive value 40.8%, the negative predictive value 98.8%. Conclusion : With rapid antigen detection test, it is possible early detection of influenza in children. reduction in use of antimicrobial agent and early use of antiviral agent.

  • PDF

Hepatic Angiomyolipoma: Contrast Patterns with SonoVue-enhanced Real-time Gray-scale Ultrasonography

  • Wei, Rui-Xue;Wang, Wen-Ping;Ding, Hong;Huang, Bei-Jian;Li, Chao-Lun;Fan, Pei-Li;Hou, Jun;He, Nian-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.2
    • /
    • pp.493-497
    • /
    • 2012
  • This study was conducted to retrospectively evaluate the pattern of contrast enhancement with SonoVue on gray-scale ultrasonography of hepatic angiomyolipoma (HAML). Imaging features of 33 pathologically proven HAML lesions in 33 patients who underwent baseline ultrasound and contrast-enhanced ultrasonography (CEUS) were assessed retrospectively. All lesions were enhanced in the arterial phase and showed whole-tumor filling in. Thirty-two of 33 (97%) lesions showed early positive enhancement in the arterial phase. Twenty-three of these exhibited isoechoic or hyperechoic features in the portal phase. HAML demonstrate characteristic manifestations with SonoVue-enhanced real-time gray-scale ultrasonography.

Clinical Effects of Oseltamivir in Children with Influenza in Busan, in the First Half of 2004 (2004년 상반기에 부산 지역 소아에서 유행한 독감에서 Oseltamivir의 치료 효과)

  • Park, Soo Kyoung;Choi, So Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.976-985
    • /
    • 2005
  • Purpose : Although influenza is one of the most important causes of acute respiratory tract infections in children, effective antiviral therapies are not common and there are only a few clinical studies on treatment of influenza in children. We evaluated the efficacy of oseltamivir in the treatment of naturally aquired influenza in children during the first half of 2004 in Busan. Methods : From January 2004 to June 2004, throat swabs and nasal washes were performed and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The children who responded positively to the QuickVue influenza test, we divided into two groups : an oseltamivir treatment group and a control group. We compared their clinical symptoms(including fever duration) and diagnosis. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : A total of 621 individuals were suspected of influenza infection. Influenza viruses were isolated in 79(17.2 percent) out of 621 patients examined. QuickVue influenza tests were positive in 181 cases. The treatment group(83 individuals) received oseltamivir twice daily for 5 days, and the control group(99 individuals) were administered only symptom relief medicine. There was no differences between the two groups in clinical diagnosis and symptoms. Oseltamivir treatment reduced the fever duration and other respiratory symptoms. There were no adverse events associated with oseltamivir treatment. Conclusion : Our data suggest that oral oseltamivir treatment reduces the fever duration and other respiratory symptoms of acute influenza without side effects in children.