• Title/Summary/Keyword: Von mises stress

Search Result 534, Processing Time 0.027 seconds

Three-Dimensional Finite element analysis of Canine and Carnassial for Observation of Dog Bite forces (개(犬)의 교합력 관찰을 위한 견치와 열육치의 3차원 유한요소 분석)

  • Park, Yu-Jin;Kim, Chi-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.295-301
    • /
    • 2019
  • Purpose: This study is for the prosthesis of dogs. Observe the occlusal relation between the dog's canine and carnassial teeth. The strength and the direction of the occlusal by 3D FEM analysis. Methods: The mandibular canine and carnassial of dogs were tested. The dog's skull was contact point confirmed by dental CAD. The skull of the dog was 3D modeled by CT. The 3D model was analyzed by ABAQUS. Opening and closing movement has been a force of 100N, 200N, 300N, 500N, 1000N, 1,500N. The peak von Mises stress distribution was confirmed. Results: As occlusal force increased, stress appeared to 1.34 MPa, 3.32 MPa, 5.00 MPa, 6.19 MPa, 5.58 MPa, 5.47 MPa in left canine. and Stress was seen at 2.10 MPa, 3.08 MPa, 3.89 MPa, 5.50 MPa, 7.04 MPa, 7.18 MPa in the right canine. Stress appeared at 2.41 MPa, 3.53 MPa, 5.15 MPa, 7.28 MPa, 31.26 MPa, 67.22 MPa in the left carnassial. and Stress was seen at 1.57 MPa, 2.96 MPa, 3.76 MPa, 6.01 MPa, 20.94 MPa, 64.38 MPa in the right carnassial. Conclusion: Peak von Mises stress values were found at the peak of the canine, the buccal of the central cusp of the carnassial, and the occlusal surface of the distal cusp.

A Basic Study on the Stress Field in the Electrode Interface of the Planar SOFC Single Cell (평판형 SOFC 단전지 전극계면에서 발생되는 응력장에 관한 기초적 연구)

  • Park, Chul Jun;Kwon, Oh Heon;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.5-9
    • /
    • 2013
  • Recently, eco-friendly sources of energy by fuel cells that use hydrogen as an energy source has emerged as the next generation of energy to solve the problem of environmental issues and exhaustion of energy. A solid oxide fuel cell(SOFC) classified based on the type of ion transfer mediator electrolyte has actively being researched. However, the reliability according to the thermal cycle is low during the operation of the fuel cell, and deformation problem comes from the difference in thermal expansion coefficient between the electrode material, the components made of ceramic material is also brittle, which means disadvantages in terms of the strength. Therefore, in this study, considering the states of the manufacturing and operating of SOFC single cells, the stress analyses in the each of the interfacial layer between the anode, electrolyte and the cathode were performed to get the basic data for reliability assessment of SOFC. The obtained results show that von Mises stress according to the thickness direction on operating state occurred maximum stress value in the electrolyte layer. And also the stresses inside the active area on a distance of 1 ${\mu}m$ from the electrode interface were estimated. Futhermore the evaluation was done for the variation of the stress according to the stage of the operation divided into three stages of manufacturing, stack, and operating.

A Finite element stress analysis of abutment screw according to the implant abutment material (임플란트 지대주 재질에 따른 지대주나사의 유한요소 응력 분석)

  • Kim, Nam-Sic;Lee, Myung-Kon;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Purpose: The present study was to determine the stress distribution of an abutment screw according to implant abutment material. Methods: This study was a tightening torque 10 Ncm, 20 Ncm, set to 30 Ncm, and a titanium alloy (Ti-6Al-4V), PEEK (polyetheretherketone), Endoligns (60% Carbon Fiber Reinforced PEEK) material of the custom abutment titanium alloy (Ti-6Al-4V) the stress distribution in the material of the abutment screw will be evaluated by the finite element analysis. Results: Abutment screw most stress has been concentrated on the interface between the fixture and the abutment was also part of the interface that the threads are started. Depending on the abutment of the abutment screw Material von Mises stress values are shown differently. 10Ncm T10 under the tightening torque of 294.2 MPa, P10 is 562.8 MPa, appeared to E10 is 295.8 MPa, 20Ncm tightening torque under T20 is 581.1 MPa, P20 is 1125 MPa, E20 was shown to 585.1 MPa, 30Ncm tightening torque under T30 is 918.2 MPa, P30 is 1795 MPa, E30 has appeared 925.1 MPa. Conclusion: If the abutment is used as Endoligns, it was confirmed that the abutment screw exhibits of von Mises stress value is similar to the titanium alloy abutment.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Deriving Probability Models for Stress Analysis

  • Ahn Suneung
    • Proceedings of the Society of Korea Industrial and System Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.139-149
    • /
    • 2002
  • This paper presents an approach to derive probability models for use in structural reliability studies. Two main points are made. First, that it is possible to translate engineering and physics knowledge into a requirement on the form of a probability model. And second, that making assumptions about a probability model for structural failure implies either explicit or hidden assumptions about material and structural properties. The work is foundational in nature, but is developed with explicit examples taken from planar and general stress problems, the von Mises failure criterion, and a modified Weibull distribution.

  • PDF

The Fire induced Thermal Stress Analysis of PC Box Bridge (PC Box교량의 화재에 대한 열응력해석)

  • 최창근;이계희;최인혁;김일곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.125-132
    • /
    • 1998
  • In this study the fire, due to overturning of oil tanker on the bridge induced heat transfer analysis and thermal stress analysis are carried out. The results of analysis for fire history of 1 hour present very large thermal gradient near the surface. However, the temperature increase of tendon & rebar that is the main resistant member of bridge is not sufficient to change material properties. The Von-Mises yield criteria is used to calculate the depth of delamination, The depth of delamination is about 4cm at center of fire and this value is close to measured value.

  • PDF

Failure Study for Knee Joint Through 3D FE Modeling Based on MR Images (자기공명영상 기반 3차원 유한요소모델링을 통한 무릎관절의 파손평가)

  • Bae, Ji-Yong;Park, Jin-Hong;Song, Seong-Geun;Park, Sang-Jin;Jeon, In-Su;Song, Eun-Kyoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.6
    • /
    • pp.533-539
    • /
    • 2009
  • In this study, the femur, the tibia, the articular cartilage and the menisci are three dimensionally reconstructed using MR images of healthy knee joint in full extension of 26-year-old male. Three dimensional finite element model of the knee joint is fabricated on the reconstructed model. Also, the FE models of ligaments and tendons are attached on the biologically suitable position of the FE model. Bones, articular cartilages and menisci are considered as homogeneous, isotropic and linear elastic materials, and ligaments and tendons are modeled as truss element and nonlinear elastic springs. The numerical results show the contact pressure and the von Mises stress distribution in the soft tissues such as articular cartilages and menisci which can be regarded as important parameters to estimate the failure of the tissues and the pain of the patients.

Finite Element Analysis on the Stress and Displacement Behavior Safeties of Dome Roof Structures for a LNG Storage Tank (LNG 저장탱크 돔루프 구조물의 응력 및 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.7-12
    • /
    • 2010
  • This paper presents FE analysis on the stress and displacement behavior safeties of dome roof structures for a LNG outer tank, which is constructed by sets of H beams and reinforced concrete. The excitation force of 0.2g is applied at the center of the bottom concrete structure of an outer tank. The computed FEM results indicated that the maximum von Mises stress was shown at the edge of dome roof structure and the maximum displacement was produced at the center of dome roof. The results showed that the concentrated stress and displacement were steadily increased for an increased number of H beams. This means that the number of H beams does not critically affect to the safety of the dome roof structure because the stiffness of a reinforced concrete structure is much higher than that of H beams. Thus, the number of H beams may be restricted under 60 due to a dead weight of H beams for 0.2g excitation force.

Stress Analysis and Lead Pin Shape Design in PGA (Pin Grid Array) Package (PGA (Pin Grid Array) 패키지의 응력해석 및 Lead Pin 형상설계)

  • Cho, Seung-Hyun;Choi, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.2
    • /
    • pp.29-33
    • /
    • 2011
  • Research about the geometry design of lead pin was carried based on the normal or shear stress of the interface between a lead pin and a PCB in terms of delamination failure. The taguchi method with four design factors of three levels and FEA(Finite element Analysis) are carried under $20^{\circ}$ bending and 50 ${\mu}m$ tension of lead pin. The contact width, d2, between head round and copper pad in PCB is the highest affection factor among design factors by analysis of contribution analysis. Equivalent von Mises stress of 18.7% reduction design is obtained by the parameter design of the taguchi method. Maximum normal stress occurred at contact position between solder outer surface and a Cu pad in PCB. Also, maximum shear stress happened at contact position between solder outer surface and SR layer of PCB. From these calculated results, delamination of the PGA package may be occurred from outer interface of solder to inner interface of solder.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION IN THE THREE TREATMENT OPTIONS OF IMPLANTS RESTORATIONS FOR THE POSTERIOR PARTIAL EDENTULISM (구치부 부분 무치악 결손에서 유용한 세 가지 임프란트 수복법들의 응력분산에 관한 3차원 유한요소법적 비교연구)

  • Kim, Il-Kyu;Lee, Hyeung-Uk;Ryu, Seung-Hyun;Choi, Jin-Ho;Han, Ye-Sook;Son, Choong-Yul;Byun, Hyo-In
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.3
    • /
    • pp.175-180
    • /
    • 2004
  • In this study, three treatment options to replace two posterior missing teeth were investigated using three dimensional finite element analysis: two wide(${\phi}5.0mm$) implants(the experimental model I), two standard(${\phi}3.75mm$) implants(the experimental model II), and three standard(${\phi}3.75mm$) implants(the experimental model III). Two kinds of load case were applied ; 1) perpendicular on occlusal surface(axial load), parallel on occlusal surface(lateral load). 2) perpendicular on occlusal surface(3mm lateral to central point). The results obtained from this study were as follows; value of Von-mises stress (equivalent stress) was smallest in the two wide implant among the three experimental models. It was reported that the diameter is the efficient factor than osseointegrated surface area.