• 제목/요약/키워드: Volumetric Heat Generation

검색결과 18건 처리시간 0.029초

열원이 있는 삼각형 풀의 높은 Ra수 자연대류 (HIGH Ra NUMBER NATURAL CONVECTION IN A TRIANGULAR POOL WITH A HEAT GENERATION)

  • 김종태;박래준;김환열;홍성완;송진호;김상백
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.66-74
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

Mechanistic Model of Dryout in a Heat-Generating Porous Medium

  • Kim, Seong-Ho;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.537-542
    • /
    • 1996
  • In the present work the influence of various physical parameters on the two-phase flow behavior in a self-heated porous medium has been studied using a numerical model, that is, the effects of heat generation rate, of porosity, of particle size, and of system pressure on the dryout process. To analyze the effect of these parameters, the variation of both liquid volumetric fraction and liquid axial velocity is evaluated at the steady state or at the onset of a first boiled-out region. The analysis of computational results indicate that a qualitative tendency exists between the parameters such as heat generation rate, porosity, effective particle diameter and the temporal development of the liquid volumetric fraction field up to dryout. In addition to these parameters, a variation of fluid properties such as phase density, phase viscosity due to a change of system pressure can be used for gaining insight into the nature of two-phase flow behavior up to dryout.

  • PDF

삼각형 형상의 풀 내에서 열원에 의한 자연대류 수치해석 (NATURAL CONVECTION IN A TRIANGULAR POOL WITH VOLUMETRIC HEAT GENERATION)

  • 김종태;박래준;김환열;송진호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.302-310
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

  • PDF

The Effect of Some Physical Parameters on Saturation and Velocity Profiles in a Porous Medium

  • Ghyym S. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.120-125
    • /
    • 1997
  • In the present work the influence of various physical parameters on the two-phase flow behavior in a self-heated porous medium has been studied using a numerical model, that is, the effects of heat generation rate, of porosity, of particle size, and of system pressure on the dryout process. To analyze the effect of these parameters, the variation of both liquid volumetric fraction (i.e., liquid saturation) and liquid axial velocity is evaluated at the steady state or at the onset of a first boiled-out region. The analysis of computational results indicate that a qualitative tendency exists between the parameters such as heat generation rate, porosity, effective particle diameter and the temporal development of the liquid volumetric fraction field up to dryout. In addition to these parameters, a variation of fluid properties such as phase density, phase viscosity due to a change of system pressure can be used for gaining insight into the nature of two-phase flow behavior up to dryout.

  • PDF

철도터널 화재 시 구난역 내의 연기거동에 대한 수치해석 연구 (Numerical Investigation on Smoke Behavior in Rescue Station for Tunnel Fires)

  • 홍사훈;유홍선;이성혁
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1740-1746
    • /
    • 2008
  • The present study performed numerical investigation to analyze the smoke behavior in the rescue station by using the commercial CFD code (FLUENT Ver 6.3). The present study adopted a 10MW ultrafast mode for simulation, and it also used the MVHS(Modify Volumetric Heat Source) model modified from the original VHS(Volumetric Heat Source) model in order to treat the product generation and the oxygen consumption under the stoichiometric state. In addition, the present simulation includes the species conservation equation for the materialization of heat source and the estimation of smoke movement. From the results, the smoke flows are moving along the ceiling because of thermal buoyancy force and as time goes, the smoke gradually moves downward at the vicinity of the entrance. Moreover, without using ventilation, it is found that the smoke flows no longer spread across the cross-passages because the pressure in the non-accident tunnel is higher than that in the accident tunnel.

  • PDF

철도터널 화재 시 구난역 내의 연기거동에 대한 수치해석 연구 (Numerical Investigation of Smoke Behavior in Rescue Station for Tunnel Fire)

  • 홍사훈;노경철;유홍선;이성혁
    • 한국철도학회논문집
    • /
    • 제12권1호
    • /
    • pp.25-30
    • /
    • 2009
  • 본 연구에서는 철도 화재 시 구난역에서의 화재 연기의 거동을 파악하기 위하여 상용코드를 사용하여 수치해석 하였다. 화원의 모사와 화재로 인한 생성물의 거동을 예측하기 위해 stoichiometric상태에서 연료 소모량에 따른 연소생성물의 생성률과 산소 소모율을 VHS 모델에 적용하고 종의 보존 방정식을 해석하는 HVHS 모델을 이용하였다. 해석결과 화재 연기는 온도에 따른 밀도 차에 의해 터널의 천장을 따라 이동 하였으며 열원으로부터 멀어지면서 하강하는 형태를 확인 할 수 있었다. 또한 터널 내 공기는 화원으로 집중되었으며 비사고 터널과 사고 터널의 압력 차에 의해 화재연기는 별다른 환기 시스템 없이도 비사고 터널로 유입되지 않았다.

제네틱 알고리듬을 이용한 PCB 채널 내 칩배열의 열적 최적화 (Thermal optimization of the chip arrangement in the PCB channel using genetic algorithm)

  • 백창인;이관수;김우승
    • 대한기계학회논문집B
    • /
    • 제21권3호
    • /
    • pp.405-413
    • /
    • 1997
  • A thermal optimization of the chip arrangement in the PCB channel oriented vertically and cooled by natural convection has been studied. The objective of this study is to find the chip arrangement that minimizes the maximum temperature of the entire PCB channel. SIMPLER algorithm is employed in the analysis, and the genetic algorithm is used for the optimization. The results show that the chip with a maximum volumetric heat generation rate has to be located at the bottom of the channel, and chips with relatively high heat generation rates should not be close to each other, and small chip should not be located between the large chips.

Thermal-hydraulic behavior simulations of the reactor cavity cooling system (RCCS) experimental facility using Flownex

  • Marcos S. Sena;Yassin A. Hassan
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3320-3325
    • /
    • 2023
  • The scaled water-cooled Reactor Cavity Cooling System (RCCS) experimental facility reproduces a passive safety feature to be implemented in Generation IV nuclear reactors. It keeps the reactor cavity and other internal structures in operational conditions by removing heat leakage from the reactor pressure vessel. The present work uses Flownex one-dimensional thermal-fluid code to model the facility and predict the experimental thermal-hydraulic behavior. Two representative steady-state cases defined by the bulk volumetric flow rate are simulated (Re = 2,409 and Re = 11,524). Results of the cavity outlet temperature, risers' temperature profile, and volumetric flow split in the cooling panel are also compared with the experimental data and RELAP system code simulations. The comparisons are in reasonable agreement with the previous studies, demonstrating the ability of Flownex to simulate the RCCS behavior. It is found that the low Re case of 2,409, temperature and flow split are evenly distributed across the risers. On the contrary, there's an asymmetry trend in both temperature and flow split distributions for the high Re case of 11,524.

액화천연가스를 활용한 개방형 랭킨 사이클에 적용한 냉열 발전의 최적화에 대한 연구 (Optimization Study on the Open-Loop Rankine Cycle for Cold Heat Power Generation Using Liquefied Natural Gas)

  • 김영우;이중성;이종집;김동선;조정호
    • 한국수소및신에너지학회논문집
    • /
    • 제28권3호
    • /
    • pp.295-299
    • /
    • 2017
  • In this study, computer simulation and optimization works have been performed for an open-loop Rankine cycle to generate power using five cases of liquefied natural gas compositions. PRO/II with PROVISION V9.4 from Schneider electric company was used, and the Soave-Redlich-Kwong equation of the state model was utilized for the design of the power generation cycle. It was concluded that more power was obtained from less molecular weight liquefied natural gas since there was more volumetric flow rate with less molecular weight.

유한요소법을 이용한 용접공정 모사 시 입열 방법에 따른 용접잔류응력의 영향 (Weld Residual Stress According to the Ways of Heat Input in the Simulation of Weld Process using Finite Element Analysis)

  • 양준석;박치용;이경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.98-103
    • /
    • 2008
  • This paper is to discuss distribution of welding residual stresses of a ferritic low alloy steel nozzle with dissimilar metal weld using Alloy 82/182. Two dimensional (2D) thermo-mechanical finite element analyses are carried out to simulate multi-pass welding process on the basis of the detailed and fabrication data. On performing the welding analysis generally, the characteristics on the heat input and heat transfer of weld are affected on the weld residual stress analyses. Thermal analyses in the welding heat cycle process is very important process in weld residual stress analyses. Therefore, heat is rapidly input to the weld pass material, using internal volumetric heat generation, at a rate which raises the peak weld metal temperature to $2200^{\circ}C$ and the base metal adjacent to the weld to about $1400^{\circ}C$. These are approximately the temperature that the weld metal and surrounding base materials reach during welding. Also, According to the various ways of appling the weld heat source, the predicted residual stress results are compared with measured axial, hoop and radial through-wall profiles in the heat affected zone of test component. Also, those results are compared with those of full 3-dimensional simulation.

  • PDF