• Title/Summary/Keyword: Volume reduction

Search Result 1,773, Processing Time 0.028 seconds

Effect of a Needle Aspiration in Patients with Lymphedema (암 수술 후 발생한 림프부종 환자의 바늘 흡인술 효과)

  • Yang, Gu-Hwan;Kwak, Sung-Wook;Kim, Sun-Hyn;Shin, Young-Tae;Hwang, Hee-Jin;Park, No-Hyeok;Yeom, Chang-Hwan
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2009
  • Purpose: Lymphedemas are tissue fluid swellings, usually on the arms or legs, and occur as a result of impaired lymphatic drainage. Presently, the most effective treatment available is complete decongestive physiotherapy (CDP). However, this therapy is ineffective in some patients and surgery may be indicated. Herein, we examined the efficacy of minimally invasive needle aspiration of the most enlarged areas in hypodermic adipose tissues, of patients who had failed CDP. Methods: We included 21 patients who were diagnosed with lymphedema stage II-III in the upper or lower extremities and visited the lymphedema clinic at a university hospital from September 1, 2003 to February 28, 2004. All patients had been treated with CDP at least once, but had failed to respond to the therapy for more than one year. Nine patients had breast cancer and 12 had cervical cancer. We identified the area with the most severe edema by using MRI and performed a 16-gauge angio-needle aspiration on the area. The patients were followed up for 3 months. Effectiveness of the treatment was evaluated by comparing the volume of edema before and after the treatment using Wilcoxon signed rank-test. Results: The mean reduction ratio of the volume of edema comparison normal volume was 41.1${\pm}$35.3% (P=0.001). There were no major or minor operative complications except localized hemorrhage. Conclusion: We conclude that a needle aspiration prior to other surgical treatments is relatively safe and effective for those patients who are unresponsive to CDP.

  • PDF

Damage Analysis of Korean White Pine Stands in which the Black-tipped Sawfly was Chemically Controlled (잣나무넓적잎벌 방제림분(防除林分)에 대(對)한 잣나무 피해해석(被害解析))

  • Chung, Sang Bae;Kim, Chul Su
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.3
    • /
    • pp.328-333
    • /
    • 1998
  • To obtain basic information for establishing a pest control strategy for insect pest management system, changes in the population densities of the black-tipped sawfly(Acantholyda posticalis posticalis Matsumura) and damage patterns in tree growth were investigated in national forests in Hoigok-ri, Kapyung-gun, Kyunggi-do, where the pest control measures were taken. The results obtained were as follows ; 1. The larval density in the soil of the forests where the insecticides were applied have been kept below economic threshold for about 7 years. The density was the highest in the middle of slopes and similar to the level of the early stage of the insect outbreak. 2. After the pest control by insecticides, reduction in tree height and diameter growth lasted for 2-3 years in trees defoliated by over 70%. 3. The diameter growth of the trees damaged by black-tipped sawfly recovered faster in upper stem than in the lower. 4. volume growth of the trees defoliated over 70% by the insect decreased for three to four years. The volume loss of trees defoliated by 70% and 90% was 19.6% and 54.0%, respectively. 5. Maintaining the rate of defoliation below 50%, which is the economic threshold, by chemical control measures had an effect of reducing the tree volume loss by $40m^2/ha$ as compared with a stand defoliated by 90%.

  • PDF

Correlation between the Seoul Neuropsychological Screening Battery of the Parkinson's Disease Patient with Mild Cognitive Impairment and Change of the Cerebral Ventricle Volume in the Brain MRI (경도인지장애를 동반한 파킨슨병 환자의 서울신경심리검사와 뇌 자기공명영상에서 뇌실 체적 변화에 대한 상관관계)

  • Lee, Hyunyong;Kim, Hyeonjin;Im, Inchul;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.231-240
    • /
    • 2014
  • The purpose of this study were to analyze that the Seoul neuropsychological screening battery (SNSB) for the evaluating cognitive assessment of the Parkinson's disease patients with mild cognitive impairment (PD-MCI) and the changes of the cerebral ventricle volume in the brain magnetic resonance imaging (MRI), and we has been bring forward the guideline to determine the diagnostic criteria for the PD-MCI. To achieve this, we was diagnosed with Parkinson's disease patients (PD-MCI group: 34 patients; Parkinson's disease with normal cognition, PD-NC group: 34 patients) to perform the SNSB test for the attention, language, memory, visuospatial, and frontal/executive functions and the brain MRI. Additionally, to compared the change of the cerebral ventricle volume, we performed the brain MRI for the 32 normal control (NC) group. The volumetric analysis for a specific cerebral ventricle performed by using Freesurfer Ver. 5.1 (Massachusetts general Hospital, Boston MA, USA). As a results, compared to the PD-NC group, the PD-MCI group were statistically significant reduction in the ability to perform the memory and the visuospatial function (p<0.05). The volumetric changes for a specific cerebral ventricle were statistically significant variation in the left and right lateral ventricle, left and right inferior lateral ventricle, and 3rd ventricle. Although, in order to compared the objectification, the normalized percentage applied to the volumetric changes showed to extend the PD-MCI group than the PD-NC group. Specially, the left and right ventricle extension for the PD-MCI patients conspicuously had showed a quantitative linear relationship between the memory and the visuospatial function for the SNSB (r>0.5, p<0.05). Therefore, we were able to judge the diagnostic criteria of the PD-MCI through that can observe the volumetric variation of the specific cerebral ventricle by using Freesurfer in brain MRI, and to analyze the correlation between the SNSB.

Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact (Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가)

  • Choi, Ji Hun;Park, Jin Hong;Choi, Byung Don;Won, Hui Su;Chang, Nam Jun;Goo, Jang Hyun;Hong, Joo Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.191-197
    • /
    • 2014
  • Purpose : This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. Materials and Methods : By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, $15{\time}15cm2$ and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. Results : In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. Conclusion : The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

The Analysis and Strengthening Method of Export Competitive Power of Medical Device Industry - With Respect to Medical Device Industry in Gangwon Area (의료기기산업의 수출경쟁력 분석 및 강화방안 -강원지역 의료기기산업을 중심으로-)

  • Lee, Kang-Bin
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.45
    • /
    • pp.191-238
    • /
    • 2010
  • The purpose of this paper is to make research on the trend of the worldwide medical device market, the trend of the medical device market in the major foreign countries, the present status of the medical device industry in Korea and Gangwon area, the present status of export competitive power and the SWOT analysis of competitive power of the medical device industry in Gangwon area, and the strengthening methods of export competitive power of the medical device industry in Gangwon area. As the research method, the questionaire for the strengthening of export competitive power of the medical device industry in Gangwon area was carried out from August 13 to Otober 22, 2009. The worldwide medical device market in 2008 is estimated at USD 210.2 billion, with the United States being the largest market, followed closely by Japan and Western Europe. In 2006, the worldwide export amount of medical devices recorded USD 121.1 billion and the worldwide import amount of medical devices recorded USD 126.3 billion. As of the end of 2008, the number of Korea's medical device manufacturers expanded to 1,726. The production amount of Korea's medical device industry in 2008 recorded 2,525 billion won, and the domestic market volume of medical devices in 2008 recorded 3,618 billion won. Korea's export amount of medical devices in 2008 recorded USD 1,132 million and recorded a 9.67% growth compared to the previous year, and the import amount of medical devices recorded USD 2,123 million and recorded a 1.43% reduction compared to the previous year. As of the end of 2008, the number of Gangwon area's medical device manufacturers expanded to 81. The production amount of Gangwon area's medical industry in 2008 recorded 380 billion won, and Gangwon area's export amount of medical devices recorded USD 269 million and recorded a 0.25% reduction compared to the previous year, and the import amount of medical devices recorded USD 3 million and recorded a 39.63% reduction compared to the previous year. According to the result analysis of the questionaire for the strengthening of export competitive power of medical device industry in Gangwon area(August 13~October 22, 2009), the competing country of the export medical device is the United States being the highest ranking. Comparing to the collective competitive power level 100 of the competing country, the collective competitive level of the export medical device is 60 below and 70-80 below being the highest ranking. Comparing to the quality level 100 of the United States, EU and Japan, the quality level of the export medical device is 80-90 below being the highest ranking. Comparing to the design level 100 of the United States, EU and Japan, the design level of the export medical device is 90-100 below being the highest ranking. Comparing to the technology level 100 of the United States, EU and Japan, the technology level of the export medical device is 80-90 below being the highest ranking. According to the SWOT analysis of competitive power of medical device industry in Gangwon area, the strength is the abundant expert manpower of the medical device in Wonju area. The weakness is the fragility of the brand recognition of the medical device industry. The opportunity is the demand increase of the new medical device owing to the advanced age of population. The threat is the difficulty of entry into overseas market owing to the request of the new specification certification of the medical device. In order to strengthen the export competitive power of the medical device industry in Gangwon area, the following measures should be taken by the government, local self-government body, related organization and medical device industry : the development of new technology and design, the enhancement of brand recognition. the acquisition of the foreign specification certification, the building of overseas distribution channel and after sales service channel, the positive participation in overseas medical device exhibition and opening of medical device exhibition, the training of expert manpower, the strengthening of overseas marketing, and the application of FTA and the establishment of counter measures against FTA. In conclusion, the medical device industry in Gangwon area has the difficulty in the entry into the overseas market owing to the shortage of overseas marketing capability. Therefore, the government and local self-government body should make the intensive and systematical support for overseas marketing of the medical device industry. For the support of overseas marketing, the government and local self-government body should provide positively the support of expenses for the acquisition of foreign specification certification, the support of participation in the overseas medical device exhibition, the despatch of market development mission, the increase of the support amount for R&D investment fund, and the training of expert manpower of medical devices.

  • PDF

Radiographic change of grafted sinus floor after maxillary sinus floor elevation and placement of dental implant (상악동저 거상술과 임플란트 식립 후 상악동저 변화에 대한 연구)

  • Cho, Sang-Ho;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.345-359
    • /
    • 2006
  • Loss of maxillary molar teeth leads to rapid loss of crestal bone and inferior expansion of the maxillary sinus floor (secondary pneumatization). Rehabilitation of the site with osseointegrated dental implants often represents a clinical challenge because of the insufficient bone volume resulted from this phenomenon. Boyne & James proposed the classic procedure for maxillary sinus floor elevation entails preparation of a trap door including the Schneiderian membrane in the lateral sinus wall. Summers proposed another non-invasive method using a set of osteotome and the osteotome sinus floor elevation (OSFE) was proposed for implant sites with at least 5-6mm of bone between the alveolar crest and the maxillary sinus floor. The change of grafted material in maxillary sinus is important for implant survival and the evaluation of graft height after maxillary sinus floor elevation is composed of histologic evaluation and radiomorphometric evaluation. The aim of the present study was radiographically evaluate the graft height change after maxillary sinus floor elevation and the influence of the graft material type in height change and the bone remodeling of grafts in sinus. A total of 59 patients (28 in lateral approach and 31 in crestal approach) who underwent maxillary sinus floor elevation composed of lateral approach and crestal approach were radiographically followed for up to about 48 months. Change in sinusgraft height were calculated with respect to implant length (IL) and grafted sinus height(BL). It was evaluated the change of the graft height according to time, the influence of the approach technique (staged approach and simultaneous approach) in lateral approach to change of the graft height, and the influence of the type of graft materials to change of the graft height. Patients were divided into three class based on the height of the grafted sinus floor relative to the implant apex and evaluated the proportion change of that class (Class I, in which the grafted sinus floor was above the implant apex; Class II, in which the implant apex was level with the grafted sinus floor; and Class III, in which the grafted sinus floor was below the implant apex). And it was evaluated th bone remodeling in sinus during 12 months using SGRl(by $Br\ddot{a}gger$ et al). The result was like that; Sinus graft height decreased significantly in both lateral approach and crestal approach in first 12 months (p$MBCP^{TM}$ had minimum height loss. Class III and Class II was increased by time in both lateral and crestal approach and Class I was decreased by time. SGRI was increased statistically significantly from baseline to 3 months and 3 months(p<0.05) to 12 months(p$ICB^{(R)}$ single use, more reduction of sinusgraft height was appeared. Therefore we speculated that the mixture of graft materials is preferable as a reduction of graft materials. Increasing of the SGRI as time goes by explains the stability of implant, but additional histologic or computed tomographic study will be needed for accurate conclusion. From the radiographic evaluation, we come to know that placement of dental implant with sinus floor elevation is an effective procedure in atrophic maxillary reconstruction.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients (토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가)

  • Woo, Joong-Yeol;Kim, Joo-Ho;Kim, Joon-Won;Baek, Jong-Geal;Park, Kwang-Soon;Lee, Jong-Min;Son, Dong-Min;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.157-165
    • /
    • 2012
  • Purpose: We evaluated usefulness of abdominal compressor for stereotactic body radiotherapy (SBRT) with unresectable hepatocellular carcinoma (HCC) patients and hepato-biliary cancer and metastatic liver cancer patients. Materials and Methods: From November 2011 to March 2012, we selected HCC patients who gained reduction of diaphragm movement >1 cm through abdominal compressor (diaphragm control, elekta, sweden) for HT (Hi-Art Tomotherapy, USA). We got planning computed tomography (CT) images and 4 dimensional (4D) images through 4D CT (somatom sensation, siemens, germany). The gross tumor volume (GTV) included a gross tumor and margins considering tumor movement. The planning target volume (PTV) included a 5 to 7 mm safety margin around GTV. We classified patients into two groups according to distance between tumor and organs at risk (OAR, stomach, duodenum, bowel). Patients with the distance more than 1 cm are classified as the 1st group and they received SBRT of 4 or 5 fractions. Patients with the distance less than 1 cm are classified as the 2nd group and they received tomotherapy of 20 fractions. Megavoltage computed tomography (MVCT) were performed 4 or 10 fractions. When we verify a MVCT fusion considering priority to liver than bone-technique. We sent MVCT images to Mim_vista (Mimsoftware, ver .5.4. USA) and we re-delineated stomach, duodenum and bowel to bowel_organ and delineated liver. First, we analyzed MVCT images to check the setup variation. Second we compared dose difference between tumor and OAR based on adaptive dose through adaptive planning station and Mim_vista. Results: Average setup variation from MVCT was $-0.66{\pm}1.53$ mm (left-right) $0.39{\pm}4.17$ mm (superior-inferior), $0.71{\pm}1.74$ mm (anterior-posterior), $-0.18{\pm}0.30$ degrees (roll). 1st group ($d{\geq}1$) and 2nd group (d<1) were similar to setup variation. 1st group ($d{\geq}1$) of $V_{diff3%}$ (volume of 3% difference of dose) of GTV through adaptive planing station was $0.78{\pm}0.05%$, PTV was $9.97{\pm}3.62%$, $V_{diff5%}$ was GTV 0.0%, PTV was $2.9{\pm}0.95%$, maximum dose difference rate of bowel_organ was $-6.85{\pm}1.11%$. 2nd Group (d<1) GTV of $V_{diff3%}$ was $1.62{\pm}0.55%$, PTV was $8.61{\pm}2.01%$, $V_{diff5%}$ of GTV was 0.0%, PTV was $5.33{\pm}2.32%$, maximum dose difference rate of bowel_organ was $28.33{\pm}24.41%$. Conclusion: Despite we saw diaphragm movement more than 5 mm with flouroscopy after use an abdominal compressor, average setup_variation from MVCT was less than 5 mm. Therefore, we could estimate the range of setup_error within a 5 mm. Target's dose difference rate of 1st group ($d{\geq}1$) and 2nd group (d<1) were similar, while 1st group ($d{\geq}1$) and 2nd group (d<1)'s bowel_organ's maximum dose difference rate's maximum difference was more than 35%, 1st group ($d{\geq}1$)'s bowel_organ's maximum dose difference rate was smaller than 2nd group (d<1). When applicating SBRT to HCC, abdominal compressor is useful to control diaphragm movement in selected patients with more than 1 cm bowel_organ distance.

  • PDF

The Principles of Total Quality Management(TQM) and Its Implementation. (총체적 질관리(Total Quality Management)의 이론적 배경과 그 적용실태)

  • Kang, So-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.388-407
    • /
    • 1995
  • This study is (a) to describe the history of Total Quality Management (TQM) generated in the industry, health care service, and nursing society ; (b) to define the concept, total quality management including the definition of quality ; (C) to explain the each principle of TQM theory developed by main theorists, E. Deming, J. Juran, and B. Crosby ; (d) to give the examples related to TQM implementation at the health care organization ; and (e) to mention the extent to which the health care organizations are able to evaluate their cultural organization toward TQM and have had the way to measure the effect of TQM implementation. TQM referred to Continuous Quality Improvement(CQI), Quality Improvement(QI), and Total Quality Improvement(TQI), was not recognized by experts in the United States industry, but by economists in Japan until the end of the 1970's. However, the United States' government led to introduce the principles of TQM to general industry as well as health care service area so that TQM became a main philosophy to manage the organizations in health care service. TQM is a structured, systematic process for creating organization-wide participation in planning and implementing continuous improvement in quality. E. Deming established the "Chain reaction in Quality" and the fourteen point of TQM. The Chain reaction in quality is to describe the relationship among the reduction of waste, rework, and delay, quality improvement, customer satisfaction, and productivity. There are fourteen points to explain the principles of TQM by E. Deming. Juran defined the "Quality Trilogy" to improve the level of quality in any organization. Quality Trilogy has three steps such as quality planning, quality control, and quality improvement for implementing the TQM projects. Crosby describes his TQM theory by establishing "Four Absolutes" and "Fourteen steps in TQM" implementation. Until now, most healthcare organizations have made efforts to organize the TQM task team and to implement TQM principles with various issues. There are three priorities to select the TQM issues : High-volume, High-risk, and Problem-prone. However, there is no absolute, credible measurement yet to evaluate the effects of TQM implementation in health care organization regardless of the classification of health care organizations, geographical background, and social influence. Thus, developing the evaluation way in terms of TQM is the foremost task in health service area. The most important thing for TQM implementation in the organization is to settle up the concept, cultural transformation from traditional management toward quality.

  • PDF

An Analysis of Port Competitiveness by the Region - Based on Port Calling Patterns of the Ocean Container Liners - (지역별 항만 경쟁력 분석 - 컨테이너 정기선사의 항만 기항 패턴을 중심으로 -)

  • Kim, Tae-Won;Kwak, Kyu-Seok;Nam, Ki-Chan
    • Journal of Navigation and Port Research
    • /
    • v.30 no.10 s.116
    • /
    • pp.809-817
    • /
    • 2006
  • Shipping and ports have important roles as the nodes and links in maritime logistics. The environment between shipping and ports is interrelated and has been changing' together. Recently, the changes of shipping and ports are rapidly in progress and it is expected to be developed complementarily. Especially, mega carriers reduce the number of ports of calls because the size of ships is becoming bigger and bigger and the 'hub and spokes' strategy is appeared. Therefore, the position of a hub port by the region has questioned This paper aims to research the competitive ports by the region on the basis of the patterns when mega carriers call at ports. Six regions, Far East, Southeast Asia, Northwest America, Northeast America, West Europe and Mediterranean, are organized for this research. According to the volume of cargoes, the top five ports of each region are analyzed. As a result, the competitive ports by the region are Shanghai, Hong Kong, Los Angeles, New York New Jersey, Rotterdam and Gioia Tauro.