• Title/Summary/Keyword: Volume reconstruction

Search Result 411, Processing Time 0.03 seconds

Surgical Results of Monocusp Implantation with Transannular Patch Angioplasty in Tetralogy of Fallot Repair

  • Jang, Woo Sung;Cho, Joon Yong;Lee, Jong Uk;Lee, Youngok
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Monocusp reconstruction with a transannular patch (TAP) results in early improvement because it relieves residual volume hypertension during the immediate postoperative period. However, few reports have assessed the long-term surgical outcomes of this procedure. The purpose of the present study was to evaluate the mid-term surgical outcomes of tetralogy of Fallot (TOF) repair using monocusp reconstruction with a TAP. Methods: Between March 2000 and March 2009, 36 patients with a TOF received a TAP. A TAP with monocusp reconstruction (group I) was used in 25 patients and a TAP without monocusp reconstruction (group II) was used in 11 patients. We evaluated hemodynamic parameters using echocardiography during the follow-up period in both groups. Results: At the most recent follow-up echocardiography (mean follow-up, 8.2 years), the mean pulmonary valve velocities of the patients in group I and group II were $2.1{\pm}1.0m/sec$ and $0.9{\pm}0.9m/sec$, respectively (p=0.001). Although the incidence of grade 3-4 pulmonary regurgitation (PR) was not significantly different between the two groups (group I: 16 patients, 64.0%; group II: 7 patients, 70.0%; p=0.735) during the follow-up period, the interval between the treatment and the incidence of PR aggravation was longer in group I than in group II (group I: $6.5{\pm}3.4years$; group II: $3.8{\pm}2.2years$; p=0.037). Conclusion: Monocusp reconstruction with a TAP prolonged the interval between the initial treatment and grade 3-4 PR aggravation. Patients who received a TAP with monocusp reconstruction to repair TOF were not to progress to pulmonary stenosis during the follow-up period as those who received a TAP without monocusp reconstruction.

Measuring the volume of powder by vision

  • SeijiIshikawa;ShigeruHarada;HiroyukiYoshinaga;KiyoshiKato
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.776-779
    • /
    • 1987
  • This paper describes a technique for measuring the volume of a pile of powder in a visual way. The volume of a fragile object whose shape is easily transformed by a slight touch of another object must be measured without any contact with it. This can be achieved by applying a three-dimensional shape reconstruction technique employed in computer vision. We have developed a measurement system that finds the volume of a pile of powder by employing a range finder, and performed an experiment of determining the volume of PVC powder piled on a table. The result of the experiment was satisfactory.

  • PDF

Numerical Study of Droplet Impact on Solid Surfaces Using a Coupled Level Set and Volume-of-Fluid Method (CLSVOF 방법을 이용한 액적-벽면 충돌에 관한 수치적 연구)

  • Suh, Young-Ho;Son, Gi-Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.744-752
    • /
    • 2003
  • A level set method is combined with the volume-of-fluid method so that the coupled method can not only calculate an interfacial curvature accurately but also can achieve mass conservation well. The coupled level set and volume-of-fluid(CLSVOF) method is efficiently implemented by employing an interface reconstruction algorithm which is based on the explicit relationship between the interface configuration and the fluid volume function. The CLSVOF method is applied for numerical simulation of droplet impact on solid surfaces with variable contact angles. The numerical results are found to preserve mass conservation and to be in good agreement with the data reported in the literature. Also, the present method proved to be applicable to the complex phenomena such as breakup and rebound of a droplet.

Measurement of 3D Flow inside Micro-tube Using Digital Holographic PTV Technique (디지털 Holographic PTV기법을 이용한 미세튜브 내부 3차원 유동장 측정)

  • Kim, Seok;Kim, Ju-Hee;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.177-178
    • /
    • 2006
  • Digital holographic particle tracking velocimetry (HPTV) is developed by single high-speed camera and single continuous laser with long coherent length. This system can directly capture 4000 hologram fringe images for 1 second through a camera computer memory. The 3D particle location is made of the reconstruction by using a computer hologram algorithm. This system can successfully be applied to instantaneous 3D velocity measurement in the water flow inside a micro-tube. The average of 100 instantaneous velocity vectors is obtained by reconstruction and tracking with the time of evolution of recorded fringes images. In the near future, we will apply this technique to measure 3D flow information inside various micro structures.

  • PDF

Biomedical Applications of Stereoscopy for Three-Dimensional Surface Reconstruction in Scanning Electron Microscopes

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • v.46 no.2
    • /
    • pp.71-75
    • /
    • 2016
  • The scanning electron microscope (SEM) offers two-dimensional (2D) micrographs of three-dimensional (3D) objects due to its inherent operating mechanisms. To overcome this limitation, other devices have been used for quantitative morphological analysis. Many efforts have been made on the applications of software-based approaches to 3D reconstruction and measurements by SEM. Based on the acquisition of two stereo images, a multi-view technique consists of two parts: (i) geometric calibration and (ii) image matching. Quantitative morphological parameters such as height and depth could be nondestructively measured by SEM combined with special software programs. It is also possible to obtain conventional surface parameters such as roughness and volume of biomedical specimens through 3D SEM surface reconstruction. There is growing evidence that conventional 2D SEM without special electron detectors can be transformed to 3D SEM for quantitative measurements in biomedical research.

Aortic Reconstruction Using a Main Pulmonary Artery Flap in an Isolated Aortopulmonary Window

  • Shin, Hong Ju;Jung, Younggi;Shin, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.52 no.4
    • /
    • pp.236-238
    • /
    • 2019
  • Aortopulmonary window (APW) is a rare cardiac anomaly that was reported to occur in only 43 cases over 33 years at a large-volume cardiac center. It can present as an isolated anomaly or in combination with another cardiac anomaly. The surgical technique for APW has evolved from simple ligation to separation of the 2 great arteries. However, because of the rarity of APW, there is no standard surgical treatment for this disease entity. Herein, we present successful aortic reconstruction using a main pulmonary artery flap after separation of the 2 great arteries in a neonate with isolated APW.

Fast Multi-GPU based 3D Backprojection Method (다중 GPU 기반의 고속 삼차원 역전사 기법)

  • Lee, Byeong-Hun;Lee, Ho;Kye, Hee-Won;Shin, Yeong-Gil
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.2
    • /
    • pp.209-218
    • /
    • 2009
  • 3D backprojection is a kind of reconstruction algorithm to generate volume data consisting of tomographic images, which provides spatial information of the original 3D data from hundreds of 2D projections. The computational time of backprojection increases in proportion to the size of volume data and the number of projection images since the value of every voxel in volume data is calculated by considering corresponding pixels from hundreds of projections. For the reduction of computational time, fast GPU based 3D backprojection methods have been studied recently and the performance of them has been improved significantly. This paper presents two multiple GPU based methods to maximize the parallelism of GPU and compares the efficiencies of two methods by considering both the number of projections and the size of volume data. The first method is to generate partial volume data independently for all projections after allocating a half size of volume data on each GPU. The second method is to acquire the entire volume data by merging the incomplete volume data of each GPU on CPU. The in-complete volume data is generated using the half size of projections after allocating the full size of volume data on each GPU. In experimental results, the first method performed better than the second method when the entire volume data can be allocated on GPU. Otherwise, the second method was efficient than the first one.

  • PDF

Forehead Reconstruction with Hydroxyapatite Cement(MimixTM) and the Check Framework (Hydroxyapatite Cement(MimixTM)와 격자틀을 이용한 전두부 재건술)

  • Cho, Hyun Woo;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.219-222
    • /
    • 2008
  • Purpose: The purpose of this study is to develop hydroxyapatite cement simplified procedures for reconstruction of craniofacial deformities. Due to its expense and characteristics of quick hardening time, it may be inappropriate for forehead reconstruction or augmentation. Therefore we hear by introduce a more precise, easy and cheap method. The authors report forehead reconstruction with hydroxyapatite cement for a patient who suffered from craniofacial deformity. Methods: Case report and literature review. Results: A 35 year old man came to us with forehead and temporal area depression. He had a history of brain operations due to traumatic epidural hematoma. A physical exam showed an evidence of right side forehead weakness sign. Authors made RP model of his skull and applied check framework with Kirschner's wires for measuring accurate volume and contour on the depressed right side forehead area on the RP model. After complete exposure of defect area by bicoronary insicion, absorbable plate which applied on skull area was removed. Using three Kirschner's wires, authors made check framework on the right forehead lively and fixed with 2-hole miniplates on the boundary of the defect. After checking asymmetry, hydroxyapatite was applied on check shape framework just above Kirschner's wire. After removing Kirschner's wire, we corrected minimal unbalance and contour with bur. Conclusion: Check framework with Kirschner's wire was very convenient and cost saving methods for forehead reconstruction with hydroxyapatite cement.

Local Flap Algorithm for the Reconstruction of Anterior Chest Wall Defects (전흉부 재건을 위한 국소 피판술의 선택)

  • Kim, Ji Hoon;Kim, Eui Sik;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.397-405
    • /
    • 2009
  • Purpose: Soft tissue defect of anterior chest wall is caused by trauma, infection, tumors and irradiation. To reconstruct damaged anterior chest wall does require to consider the patient's body condition, the cause, the location, the depth and the size of deletion, the circulation of surrounding tissue and minimization of functional and cosmetic disability. In this report, we suggest the algorithm of configuration for reconstruction methods. Methods: A retrospective study of 20 patients who underwent anterior chest wall reconstruction with pedicled musculocutaneous flap and fasciocutaneous flap was conducted. We collected the information of the patient's body condition, the cause, the size, the depth and the location of deletion, implemented flap and complication. We observed and evaluated flap compatibility, functional and cosmetic results. Patients completed survey about the extent to their satisfaction. Result: Follow up period after surgery was from 6 to 26 months, survival of flap were confirmed in all of patients' case. Two cases of local necrosis, one case of wound disruption were reported, but all these were cured by the debridement and primary closure. One hematoma and one seroma formation were observed in donor site. Longer surgery time, more bleeding amount and more transfusion volume were reported in the group of musculocutenous flap. Conclusion: Long term follow up result showed the successful reconstruction in all patients without recurrence and with minimal donor site morbidity. In addition, the patients' satisfaction for cosmetic and functional results were scaled relatively higher. This confirmed the importance of reconstruction algorithm for the chest wall reconstruction.

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.