Browse > Article
http://dx.doi.org/10.5090/kjtcs.2016.49.5.344

Surgical Results of Monocusp Implantation with Transannular Patch Angioplasty in Tetralogy of Fallot Repair  

Jang, Woo Sung (Department of Thoracic and Cardiovascular Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine)
Cho, Joon Yong (Department of Thoracic and Cardiovascular Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine)
Lee, Jong Uk (Department of Thoracic and Cardiovascular Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine)
Lee, Youngok (Department of Thoracic and Cardiovascular Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine)
Publication Information
Journal of Chest Surgery / v.49, no.5, 2016 , pp. 344-349 More about this Journal
Abstract
Background: Monocusp reconstruction with a transannular patch (TAP) results in early improvement because it relieves residual volume hypertension during the immediate postoperative period. However, few reports have assessed the long-term surgical outcomes of this procedure. The purpose of the present study was to evaluate the mid-term surgical outcomes of tetralogy of Fallot (TOF) repair using monocusp reconstruction with a TAP. Methods: Between March 2000 and March 2009, 36 patients with a TOF received a TAP. A TAP with monocusp reconstruction (group I) was used in 25 patients and a TAP without monocusp reconstruction (group II) was used in 11 patients. We evaluated hemodynamic parameters using echocardiography during the follow-up period in both groups. Results: At the most recent follow-up echocardiography (mean follow-up, 8.2 years), the mean pulmonary valve velocities of the patients in group I and group II were $2.1{\pm}1.0m/sec$ and $0.9{\pm}0.9m/sec$, respectively (p=0.001). Although the incidence of grade 3-4 pulmonary regurgitation (PR) was not significantly different between the two groups (group I: 16 patients, 64.0%; group II: 7 patients, 70.0%; p=0.735) during the follow-up period, the interval between the treatment and the incidence of PR aggravation was longer in group I than in group II (group I: $6.5{\pm}3.4years$; group II: $3.8{\pm}2.2years$; p=0.037). Conclusion: Monocusp reconstruction with a TAP prolonged the interval between the initial treatment and grade 3-4 PR aggravation. Patients who received a TAP with monocusp reconstruction to repair TOF were not to progress to pulmonary stenosis during the follow-up period as those who received a TAP without monocusp reconstruction.
Keywords
Tetralogy of Fallot; Transannular patch; Monocusp reconstruction;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chaturvedi RR, Redington AN. Pulmonary regurgitation in congenital heart disease. Heart 2007;93:880-9.   DOI
2 Hisatomi K, Isomura T, Sato T, Kosuga K, Ohishi K, Katoh H. Mitral valve repair for mitral regurgitation with ventricular septal defect in children. Ann Thorac Surg 1996;62:1773-7.   DOI
3 Brown JW, Ruzmetov M, Vijay P, Rodefeld MD, Turrentine MW. Right ventricular outflow tract reconstruction with a polytetrafluoroethylene monocusp valve: a twelve-year experience. J Thorac Cardiovasc Surg 2007;133:1336-43.   DOI
4 Park CS, Lee JR, Lim HG, Kim WH, Kim YJ. The long-term result of total repair for tetralogy of Fallot. Eur J Cardiothorac Surg 2010;38:311-7.   DOI
5 Kaza AK, Lim HG, Dibardino DJ, et al. Long-term results of right ventricular outflow tract reconstruction in neonatal cardiac surgery: options and outcomes. J Thorac Cardiovasc Surg 2009;138:911-6.   DOI
6 Sasson L, Houri S, Raucher Sternfeld A, et al. Right ventricular outflow tract strategies for repair of tetralogy of Fallot: effect of monocusp valve reconstruction. Eur J Cardiothorac Surg 2013;43:743-51.   DOI
7 Yang JH, Jun TG, Park PW, et al. Factors related to the durability of a homograft monocusp valve inserted during repair of tetralogy of Fallot as based on the mid- to long-term outcomes. Cardiol Young 2008;18:141-6.
8 Cowgill LD, Campbell DN, Kelminson L, Clarke DR. Repair of pulmonary valve insufficiency using an autologous monocusp. Ann Thorac Surg 1986;42:587-9.   DOI
9 Mahadin DR, Srivastava S, Parness IA, et al. Outcomes of mitral regurgitation associated with large ventricular septal defect and a normal mitral valve apparatus: does intact atrial septum have an impact? Pediatr Cardiol 2011;32: 1128-31.   DOI
10 Mishaly D, Birk E, Elami A, Vidne BA. Autologous monocusp pulmonary valve: preliminary results. Ann Thorac Surg 1996;61:1811-5.   DOI
11 Gundry SR. Pericardial and synthetic monocusp valves: Indication and results. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 1999;2:77-82.   DOI
12 Sasikumar D, Sasidharan B, Tharakan JA, Dharan BS, Mathew T, Karunakaran J. Early and 1-year outcome and predictors of adverse outcome following monocusp pulmonary valve reconstruction for patients with tetralogy of Fallot: a prospective observational study. Ann Pediatr Cardiol 2014;7:5-12.   DOI
13 Turrentine MW, McCarthy RP, Vijay P, Fiore AC, Brown JW. Polytetrafluoroethylene monocusp valve technique for right ventricular outflow tract reconstruction. Ann Thorac Surg 2002;74:2202-5.   DOI