• Title/Summary/Keyword: Volume of recovery water

Search Result 106, Processing Time 0.027 seconds

Determination of phenol using solid-phase extraction and HPLC/MSD/FLD in water (고체상추출법과 HPLC/MSD/FLD를 이용한 수질중의 페놀 분석)

  • Lee, Taejoon;Park, Keun-Young;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.370-376
    • /
    • 2015
  • An analytical method for determining phenol considered priority pollutants of the US EPA and precursor of toxic phenolic compounds by solid-phase extraction (SPE) and high performance liquid chromatographic systems (HPLC) equipped with fluorescence and mass selective detectors have been developed. The SPE process for sample preconcentration was performed on a commercially available Oasis HLB cartridge packed with polymeric sorbents. The effect of pH, elution solvent, and elution volume on the recoveries of the analytes were investigated with HPLC/FLD. Average recovery of >87.0% was achieved with 60 mg sorbents using 5 mL of methanol as an elution solvent at pH=3.

Accidental High Epidural Block -A case report- (우발성 고위경막외차단 경험 1예 -증례보고-)

  • Park, Jung-Goo;Cheun, Jae-Kyu
    • The Korean Journal of Pain
    • /
    • v.8 no.1
    • /
    • pp.159-163
    • /
    • 1995
  • Accidental high epidural block is a rare but serious complication. It can result from many factors, which include the volume and concentration of drug, posture, puncture site, age, pregnancy or intra-abdominal mass, and patients' height and weight. We had a case of accidental high epidural block recently. This is a case report which was confirmed by an epiduragram. A healthy 50-year-old woman with a huge uterine myoma was scheduled for a total abdominal hysterectomy under continous epidural analgesia. Epidural catheterization was carried out smoothly. However, an unexpected hypotension was noticed after an epidural injection of 2% lidocaine 25 ml. Thereafter, the patient was intubated and her respiration was controlled during the operation. Using the 5mg of ephedrine, her blood pressure and pulse were well maintained. The scheduled operation was carried out for one hour uneventfully, but after the operation, she felt paresthesia on her hands in the recovery room. To differentiate between the high epidural and the subdural blocks. We injected 5 ml of a water soluble Niopam 300 through the catheter postoperatively. It was observed on the epiduragram that the catheter was placed in the epidural space. It was suggested that the high epidural block was induced from the widespread diffusion through the narrowed epidural space due to the engorgement of the epidural venous plexus by the patient's huge uterine myoma.

  • PDF

A Study on Recycle of Concreted Organic Waste water by Electroflotation Apparatus for Resource Recycle of Non-Metal (비금속 자원 재활용을 위한 전해부상 장치를 이용한 고농도 유기질 폐수의 재활용에 관한 연구)

  • Kim, Ki-Jun;Nam, Sang-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.653-658
    • /
    • 2012
  • There is an increasing interest in the use of electrochemical methods for the food waste treatment. The technologies using the electrochemical method provide ideal tools for approaching industrial and food wastes problems. Unlike other chemical treatments, the electrochemical systems do not make the volume of the secondary waste increase. The electrochemical methods can be operated with electrochemical apparatus and inorganic agent allow selective separation and recovery and even quieter than others. This study concerns design factors, electrode construction and wastewater treatment process of the electrochemical apparatus. The experiment of color, COD and BOD removal is much effective in using electrochemical method with ultrasonication and ozonation.

Strategies to improve the range verification of stochastic origin ensembles for low-count prompt gamma imaging

  • Hsuan-Ming Huang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3700-3708
    • /
    • 2023
  • The stochastic origin ensembles method with resolution recovery (SOE-RR) has been proposed to reconstruct proton-induced prompt gammas (PGs), and the reconstructed PG image was used for range verification. However, due to low detection efficiency, the number of valid events is low. Such a low-count condition can degrade the accuracy of the SOE-RR method for proton range verification. In this study, we proposed two strategies to improve the reconstruction of the SOE-RR algorithm for low-count PG imaging. We also studied the number of iterations and repetitions required to achieve reliable range verification. We simulated a proton beam (108 protons) irradiated on a water phantom and used a two-layer Compton camera to detect 4.44-MeV PGs. Our simulated results show that combining the SOE-RR algorithm with restricted volume (SOE-RR-RV) can reduce the error of the estimation of the Bragg peak position from 5.0 mm to 2.5 mm. We also found that the SOE-RR-RV algorithm initialized using a back-projection image could improve the convergence rate while maintaining accurate range verification. Finally, we observed that the improved SOE-RR algorithm set for 60,000 iterations and 25 repetitions could provide reliable PG images. Based on the proposed reconstruction strategies, the SOE-RR algorithm has the potential to achieve a positioning error of 2.5 mm for low-count PG imaging.

Active Solar Heating System Design and Analysis for the Zero Energy Solar House (제로에너지 솔라하우스의 난방/급탕용 태양열 시스템 설계 및 분석)

  • Baek, N.C.;Yoo, C.K.;Yoon, E.S.;Yoo, J.Y.;Yoon, J.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • This study is on the design and evaluation of Zero Energy Solar House(ZeSH) including active solar heating system. Various innovative technologies such as super insulation, passive solar systems, super window, ventilation heat recovery system...etc were analyzed by individual and combination for the success of ZeSH. The ESP-r simulation program was used for this. Simulation results shows that almost 77% of heating load can be reduced with the following configuration of 200mm super insulation, super windows, passive solar system and 0.3 ventilation rate per hour. Active solar heating system (ASHS) was designed for the rest of the heating load including hot water heating load. The solar assisted heat pump is used for the auxiliary heating device in order to use air conditioner but not included in this study. The yearly solar fraction is 87% with a solar collector area of $28m^2$. The parametric studies as the influence of storage volume and collector area on the solar fraction was analyzed.

Trifluralin in aquatic products: QuEChERS and Gas chromatography-tandem mass spectrometry for trace amount detection

  • Le-Thi Anh-Dao;Do Minh-Huy;Vo Hong-Phong;Nguyen Cong-Hau
    • Analytical Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.205-215
    • /
    • 2023
  • In the present study, an analytical method was proposed for detecting trifluralin in aquatic products at trace concentrations. The method employed QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) and gas chromatography coupled with tandem mass spectrometry (GC-MS/MS) as the sample preparation and measurement, respectively. The effect of the aqueous phase volume used in the QuEChERS was demonstrated, and the ratio of 10:10 (mL) between water and acetonitrile phase was used for 5 g of sample. Besides, dSPE using C18 and primary-secondary amine (PSA) was applied to remove the potential interferences from the food matrices, indicating no remarkable analyte loss. The linear range was built up from 0.50 ㎍ L-1 to 3.0 ㎍ L-1 (R2 = 0.9993). Other criteria, i.e., repeatability (RSDr = 0.86-1.96 %), reproducibility (RSDR = 1.09-2.01 %), and recovery (over 90 %), were in accordance with Appendix F of AOAC (2016) for method performance. Although no trifluralin was detected for the commercial samples (fish, shrimp, and breaded shrimp), the spiked samples performed favorable recoveries and precision.

Speciation Analysis of Arsenic Species in Surface Water (수중의 비소 종 분리 분석)

  • Jeong, Gwan-Jo;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.621-627
    • /
    • 2008
  • In this study, a technique of speciation and determination of the trace inorganic arsenic(As(III) and As(V)) in water sample using HPLC-DRC-ICP-MS has been developed. Isocratic mobile phase of 10 mM ammonium nitrate and 10 mM ammonium phosphate monobasic was used and methanol(5 v/v%) was used as flushing solvent. Selection of the best flow rate of reaction gas, O$_2$, and optimization of the parameters such as pH and flow rate of mobile phase, and injection volume of sample for the separation and detection of arsenic species were carried out. The oxygen flow rate of 0.5 mL/min, pH of 9.4 and flow rate of 1.5 mL/min of mobile phase, and injection volume of sample of 100 $\mu$L were found to be the best parameters for the speciation and determination of arsenic species. The analytical features of the method were detection limit 0.10 and 0.08 $\mu$g/L, precision(RSD) 4.3% and 3.6%, and recovery 95.2% and 96.4% for As(III) and As(V), respectively. Analysis time was 4 minutes per sample. Linear calibration graphs with r$^2$ = 0.998 were obtained for both As(III) and As(V). Speciation analysis of arsenic species in the raw water samples collected from the tributary streams to Han River and main stream of Paldnag were performed by the proposed method. The concentrations of As(III) ranged from 0.10 to 0.22 $\mu$g/L and As(V) concentrations ranged from 0.44 to 1.19 $\mu$g/L, and 93.5% of total arsenic was found to be As(V).

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

A Study on the 2-stage dry and pyrolysis system for reduction of sewage sludge (하수슬러지 감량화를 위한 one구동 2단형 열풍건조/열분해에 관한 연구)

  • Ha, Sang-An;Kim, Seung-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.2
    • /
    • pp.52-60
    • /
    • 2004
  • The basic approach to sewage sludge is organic waste minimization, promotion of energy recovery; volume and weight reduction by final treatment, and environmentally final disposal of natural circulation. Dry and pyrolysis of maize was experimentally investigated in full-scale rotary kiln in semi-continuous operation. The operational parameters varied are the operating temperature $160{\sim}175^{\circ}C$ of dry and $450{\sim}800^{\circ}C$ of pyrolysis, the solids residence time 9 min for pyrolysis. Important parameters studied include the running time, water content of sewage sludge, solids amount of sewage sludge(TS%) by the varied temperature. Also, with the increasing of temperature, how the yield of oil and char product change was observed, and the distribution of gas production components was observed. The gas of $C_1{\sim}C_3$ yield increased and oil of $C_4{\sim}C_6$ yield decreased along with pyrolysis temperature of $670^{\circ}C$ by the run time of 9 min.

  • PDF

Preconcentration of Iron(III), Lead(II), Cobalt(II) and Chromium(III) on Amberlite XAD-1180 Resin Loaded with 4-(2-Pyridylazo)-resorcinol (PAR) and Their Determination by FAAS

  • Tokalloglu, Serife;Kartal, Senol
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.9
    • /
    • pp.1293-1296
    • /
    • 2006
  • In this study, a solid phase extraction method has been developed for the preconcentration and separation of the elements Cr(III), Fe(III), Co(II) and Pb(II) at trace levels by using a column packed with Amberlite XAD-1180 resin loaded with 4-(2-pyridylazo)-resorcinol (PAR) reagent. After preconcentrating, the metals retained on the column were eluted with 20 mL of 3 mol/L $HNO_3$ and then determined by flame atomic absorption spectrometry (FAAS). The factors affecting the recovery of the elements, such as pH, type and concentration of eluent, volume of sample and elution solution, and matrix components, were also ascertained. The recoveries of Cr(III), Fe(III), Co(II) and Pb(II) were found to be $99\;{\pm}\;4,\;97\;{\pm}\;3,\;95\;{\pm}\;3$ and $98\;{\pm}\;4$%, respectively, under the optimum conditions at 95% confidence level and the relative standard deviations found by analyzing of nine replicates were $\leq4.4$%. The preconcentration factors for Cr(III), Fe(III), Co(II) and Pb(II) were found as 75, 125, 50 and 75 respectively. The detection limits (DL, 3s/b) were 3.0 $\mu g/L$ for Cr(III), 1.25 $\mu g/L$ for Fe(III), 3.3 $\mu g/L$ for Co(II), and 7.2 $\mu g/L$ for Pb(II). The recoveries achieved by adding of metals at known concentrations to samples and the analysis results of Buffalo river sediment (RM 8704) show that the described method has a good accuracy. The proposed method was applied to tap water, stream water, salt and street dust samples.