• Title/Summary/Keyword: Volume loss(Vs)

Search Result 9, Processing Time 0.026 seconds

Characteristics of Subsidence above a Shallow Tunnel Excavated in Weathered Rock Mass (풍화암반 저심도 터널 굴착 중 발생한 지표침하의 특성)

  • Kim, Chee-Hwan
    • Tunnel and Underground Space
    • /
    • v.23 no.5
    • /
    • pp.337-346
    • /
    • 2013
  • The characteristics of subsidence above a shallow tunnel excavated in weathered rock mass is analyzed. The tunnel is excavated minimum about 11m beneath some buildings and the width of the tunnel is 11m, too. Subsidence pins are installed at 23 locations on surface along the tunnel, 180m long, adjacent to the buildings. Subsidences are measured for about 2 years and they are optimized to analyze three dimensional deformed ground surface, trough width parameter K and sectional volume loss of unit tunnel length Vs of the surface deformation profile.

The influence of membrane exposure on post-extraction dimensional change following ridge preservation technique (차폐막 노출이 발치 후 치조제 보존술의 결과에 미치는 영향에 관한 임상적 연구)

  • Nam, Hyun-Wook;Park, Yoon-Jeong;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Gu, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.367-373
    • /
    • 2009
  • Purpose: Following tooth extraction caused by severe periodontitis, alveolar ridge dimension lose their original volume. To reduce the alveolar ridge dimension, the ridge preservation technique has been introduced and tested in many clinical studies with membrane alone or membrane plus graft, achieving reduced ridge loss compared to extraction only. The aim of the present clinical study was to compare the post-extraction dimensional changes in the membrane exposure group to non-exposure group during healing period following ridge preservation technique. Methods: Ridge preservation was performed in 44 extraction sites. After extraction, deproteinized bovine bone mineral coated with synthetic oligopeptide (Ossgen-$X15^{(R)}$) or deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was implanted into the socket. A collagen membrane (Bio-$Gide^{(R)}$) was trimmed to cover the socket completely and applied to the entrance of the socket. Four clinical parameters were compared between baseline and 6 months. Results: During healing period, membrane exposure was observed at 19 sites. At the re-entry, hard newly formed tissue were observed at the ridge preservation site. The grafted socket sites were well preserved in their volume dimension. In both groups, horizontal ridge width was reduced and vertical height was increased. There were not statistically significant differences in horizontal (-1.32 mm vs -1.00 mm) and vertical ridge change (2.24 mm vs 2.37 mm at buccal crest, 1.36 mm vs. 1.53 mm at lingual crest) between two groups. Conclusions: The ridge preservation approach after tooth extraction effectively prevented resorption of hard tissue ridge in spite of membrane exposure during healing period.

Biases in the Assessment of Left Ventricular Function by Compressed Sensing Cardiovascular Cine MRI

  • Yoon, Jong-Hyun;Kim, Pan-ki;Yang, Young-Joong;Park, Jinho;Choi, Byoung Wook;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.114-124
    • /
    • 2019
  • Purpose: We investigate biases in the assessments of left ventricular function (LVF), by compressed sensing (CS)-cine magnetic resonance imaging (MRI). Materials and Methods: Cardiovascular cine images with short axis view, were obtained for 8 volunteers without CS. LVFs were assessed with subsampled data, with compression factors (CF) of 2, 3, 4, and 8. A semi-automatic segmentation program was used, for the assessment. The assessments by 3 CS methods (ITSC, FOCUSS, and view sharing (VS)), were compared to those without CS. Bland-Altman analysis and paired t-test were used, for comparison. In addition, real-time CS-cine imaging was also performed, with CF of 2, 3, 4, and 8 for the same volunteers. Assessments of LVF were similarly made, for CS data. A fixed compensation technique is suggested, to reduce the bias. Results: The assessment of LVF by CS-cine, includes bias and random noise. Bias appeared much larger than random noise. Median of end-diastolic volume (EDV) with CS-cine (ITSC or FOCUSS) appeared -1.4% to -7.1% smaller, compared to that of standard cine, depending on CF from (2 to 8). End-systolic volume (ESV) appeared +1.6% to +14.3% larger, stroke volume (SV), -2.4% to -16.4% smaller, and ejection fraction (EF), -1.1% to -9.2% smaller, with P < 0.05. Bias was reduced from -5.6% to -1.8% for EF, by compensation applied to real-time CS-cine (CF = 8). Conclusion: Loss of temporal resolution by adopting missing data from nearby cardiac frames, causes an underestimation for EDV, and an overestimation for ESV, resulting in underestimations for SV and EF. The bias is not random. Thus it should be removed or reduced for better diagnosis. A fixed compensation is suggested, to reduce bias in the assessment of LVF.

Postpartum Reproductive Management Based on the Routine Farm Records of a Dairy Herd: Relationship between the Metabolic Parameters and Postpartum Ovarian Activity

  • Takagi, Mitsuhiro;Hirai, Toshiya;Moriyama, Naoki;Ohtani, Masayuki;Miyamoto, Akio;Wijayagunawardane, Missaka P.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.787-794
    • /
    • 2005
  • The aim of this study was 1) to confirm the practical efficiency of a routine milk P4 monitoring system for postpartum reproductive management of a dairy herd, and 2) to evaluate the relationship between the blood metabolic profiles, milk quality and body weight of individual cows in the farm records, which may reflect the postpartum nutritional condition, and the time of postpartum resumption of ovarian activity of dairy cows. A total of 116 Holstein cows was used in the present study. First, during the period of Experiment 1, postpartum reproductive management based on weekly measured milk P4 concentration from individual cows was conducted. Compared with the reproductive records of the past two years without P4 monitoring, although the day from calving to first AI did not change, both the number of AI until pregnant (with P4; 1.9 times vs. without P4; 2.9 times) and the days open (with P4; 95.1 days vs. without P4; 135.8 days and 133.8 days) were significantly decreased. In Experiment 2, the measurement of blood constituents such as albumin, blood urea nitrogen, packed cell volume, ammonia, glucose, total cholesterol, non-esterified, AST and $\gamma$-GTP was performed on the blood samples taken once approximately 14 days postpartum, to monitor both health and nutritional conditions. The milk constituent parameters, such as milk protein (MP), milk fat (MF), SNF and lactose, collected from the monthly progeny test of individual cows, were used to monitor the postpartum nutritional status. Furthermore, the data obtained from the routine measurements of body weight were used to calculate the rate of peripartum body weight loss. The resumption day of the postpartum estrous cycle was assumed from the milk P4 profiles of individual cows. There was no clear relationship between each parameter from blood examination and those from resumption time. However, the cows had low values of MP, and SNF, which significantly affected the resumption of the postpartum estrous cycle. Similarly, a higher rate of body weight loss indicated a significant delay (more than 1 month) in the resumption of the postpartum estrous cycle, compared with the groups that had a medium or lower rate of body weight loss. The results of the present study demonstrated that the implementation of routine milk P4 monitoring-based postpartum reproductive management, together with milk quality parameters and routine BW data available in field conditions may be utilized as a practical approach for increasing the postpartum reproductive efficiency of a high yielding dairy herd.

Improving Diagnostic Performance of MRI for Temporal Lobe Epilepsy With Deep Learning-Based Image Reconstruction in Patients With Suspected Focal Epilepsy

  • Pae Sun Suh;Ji Eun Park;Yun Hwa Roh;Seonok Kim;Mina Jung;Yong Seo Koo;Sang-Ahm Lee;Yangsean Choi;Ho Sung Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.4
    • /
    • pp.374-383
    • /
    • 2024
  • Objective: To evaluate the diagnostic performance and image quality of 1.5-mm slice thickness MRI with deep learningbased image reconstruction (1.5-mm MRI + DLR) compared to routine 3-mm slice thickness MRI (routine MRI) and 1.5-mm slice thickness MRI without DLR (1.5-mm MRI without DLR) for evaluating temporal lobe epilepsy (TLE). Materials and Methods: This retrospective study included 117 MR image sets comprising 1.5-mm MRI + DLR, 1.5-mm MRI without DLR, and routine MRI from 117 consecutive patients (mean age, 41 years; 61 female; 34 patients with TLE and 83 without TLE). Two neuroradiologists evaluated the presence of hippocampal or temporal lobe lesions, volume loss, signal abnormalities, loss of internal structure of the hippocampus, and lesion conspicuity in the temporal lobe. Reference standards for TLE were independently constructed by neurologists using clinical and radiological findings. Subjective image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were analyzed. Performance in diagnosing TLE, lesion findings, and image quality were compared among the three protocols. Results: The pooled sensitivity of 1.5-mm MRI + DLR (91.2%) for diagnosing TLE was higher than that of routine MRI (72.1%, P < 0.001). In the subgroup analysis, 1.5-mm MRI + DLR showed higher sensitivity for hippocampal lesions than routine MRI (92.7% vs. 75.0%, P = 0.001), with improved depiction of hippocampal T2 high signal intensity change (P = 0.016) and loss of internal structure (P < 0.001). However, the pooled specificity of 1.5-mm MRI + DLR (76.5%) was lower than that of routine MRI (89.2%, P = 0.004). Compared with 1.5-mm MRI without DLR, 1.5-mm MRI + DLR resulted in significantly improved pooled accuracy (91.2% vs. 73.1%, P = 0.010), image quality, SNR, and CNR (all, P < 0.001). Conclusion: The use of 1.5-mm MRI + DLR enhanced the performance of MRI in diagnosing TLE, particularly in hippocampal evaluation, because of improved depiction of hippocampal abnormalities and enhanced image quality.

Balancing air flow at terminal in CAV duct system with DPM method (정풍량방식 덕트에서 이중압력측정방법을 이용한 취출구 풍량조정)

  • 이대우;박명식;박영우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.66-78
    • /
    • 1998
  • Adequate ventilation with the proper amount of air to the right place is important factor to achieve a good Indoor air climate. Thus it is of prime importance that the ventilation system is working properly. This requires reliable pressure loss calculation to balance the air flow through duct systems. So a computer program for balancing CAV duct system is developed In this study. The results of CAV duct system is compared with the "Balans" code developed by Larsen from Norway. To obtain the pressure drop characteristics of damper at duct terminal, some experiments are performed using DPM(Dual Pressure Measurement) system. To adjust the resistance of damper, present study suggests that some special diffusers should be designed and damper producers should give the data of air flow vs. pressure drop to the customs when they manufacture the damper. One of the results concludes that the working time can be reduced from several minutes to several seconds per damper in the present experimental site, if the DPM system and the air volume adjusting process are used.

  • PDF

The Evaluation of Composite Dose using Deformable Image Registration in Adaptive Radiotherapy for Head and Neck Cancer (두경부 종양의 적응방사선치료시 변형영상정합을 이용한 합성선량 평가)

  • Hwang, Chul-Hwan;Ko, Seong-Jin;Kim, Chang-Soo;Kim, Jung-Hoon;Kim, Dong-Hyun;Choi, Seok-Yoon;Ye, Soo-Young;Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.227-235
    • /
    • 2013
  • In adaptive radiotherapy(ART), generated composite dose of surrounding normal tissue on overall treatment course which is using deformable image registration from multistage images. Also, compared with doses summed by each treatment plan and clinical significance is considered. From the first of May, 2011 to the last of July, 2012. Patients who were given treatment and had the head and neck cancer with 3-dimension conformal radiotherapy or intensity modulated radiotherapy, those who were carried out adaptive radiotherapy cause of tumor shrinkage and weight loss. Generated composite dose of surrounding normal tissue using deformable image registration was been possible, statistically significant difference was showed to mandible($48.95{\pm}3.89$ vs $49.10{\pm}3.55$ Gy), oral cavity($36.93{\pm}4.03$ vs $38.97{\pm}5.08$ Gy), parotid gland($35.71{\pm}6.22$ vs $36.12{\pm}6.70$ Gy) and temporomandibular joint($18.41{\pm}9.60$ vs $20.13{\pm}10.42$ Gy) compared with doses summed by each treatment plan. The results of this study show significant difference between composite dose by deformable image registration and doses summed by each treatment plan, composite dose by deformable image registration may generate more exact evaluation to surrounding normal tissue in adaptive radiotherapy.

Acute Normovolemic Hemodilution Effects on Perioperative Coagulation in Elderly Patients Undergoing Hepatic Carcinectomy

  • Guo, Jian-Rong;Jin, Xiao-Ju;Yu, Jun;Xu, Feng;Zhang, Yi-Wei;Shen, Hua-Chun;Shao, Yi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4529-4532
    • /
    • 2013
  • Background: Acute normovolemic hemodilution (ANH) has been widely used to prevent the massive blood loss during hepatic carcinoma. The influences of ANH on coagulation function are still controversy, especially in elderly patients. The study observed ANH effects on coagulation function and fibrinolysis in elderly patients undergoing the disease. Materials and Methods: Thirty elderly patients (aged 60-70 yr) with liver cancer (ASA I or II) taken hepatic carcinectomy from February 2007 to February 2008 were randomly divided into ANH group (n=15) and control group (n=15). After tracheal intubation, patients in ANH group and control group were infused with 6% hydroxyethyl starch (130/0.4) and Ringer's solution, respectively. Blood samples were drawn from patients in both groups at five different time points: before anesthesia induction (T1), 30 min after ANH (T2), 1 h after start of operation (T3), immediately after operation (T4), and 24 h after operation (T5). Then coagulation function, soluble fibrin monomer complex (SFMC), prothrombin fragment (F1+2), and platelet membrane glycoprotein (CD62P and activated GP IIb/GP IIIa) were measured. Results: The perioperative blood loss and allogeneic blood transfusion were recorded during the surgery. The perioperative blood loss was not significantly different between two groups (p>0.05), but the volume of allogeneic blood transfusion in ANH group was significantly less than in control group ($350.0{\pm}70.7$) mL vs. ($457.0{\pm}181.3$) mL (p<0.01). Compared with the data of T1, the prothrombin time (PT) and activated partial thromboplastin time (APTT) measured after T3 were significantly longer (p<0.05) in both groups, but within normal range. There were no significant changes of thrombin time (TT) and D-dimer between two groups at different time points (p>0.05). SFMC and F1+2 increased in both groups, but were not statistically significant. PAC-1-positive cells and CD62P expressions in patients of ANH group were significantly lower than those at T1 (p<0.05) and T2-T5 (p>0.05). Conclusions: ANH has no obvious impact on fibrinolysis and coagulation function in elderly patients undergoing resection of liver cancer. The study suggested that ANH is safe to use in elderly patients and it could reduce allogeneic blood transfusion.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.