• Title/Summary/Keyword: Volume effect

Search Result 5,928, Processing Time 0.035 seconds

Combustion characteristics in small combustion chamber that has high surface to volume ratio (고 표면적-체적 비를 가지는 소형 연소실 환경에서의 연소특성)

  • Lee, Dae-Hoon;Choi, Kwon-Hyoung;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.212-216
    • /
    • 2000
  • Combustion phenomenon in scale-downed combustor is investigated. As the combustor volume decreases surface to volume ratio increases. for increased surface to volume ratio means increased heat loss and this increased heat loss affects reaction in combustion chamber. Plastic mini combustor is made. Stoichiometricaly premixed Hydrogen I air gas is used as fuel. Initial chamber pressure and chamber size are varied and the effects are evaluated. Peak pressure decreases with the decrease in chamber height. As initial chamber pressure decreases peak pressure decreases. And this change is more important than scale down effect till the chamber height of 1mm. With this result and further information following the experiments design parameter for micro engine can be established.

  • PDF

A Study on the Synthesis and Property of Azide Type Photosensitive Resin (Azide형 감광성수지의 합성과 특성에 관한 연구)

  • 조가람
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.1
    • /
    • pp.115-131
    • /
    • 1996
  • The PVT(pressure-volume-temperature) relation of main-chain dimer liquid crystals having structures such as $\alpha$,$\omega$-bis[(4,4`-cyanobiphenyl) oxy] alkane(CBA-n with=9, 10) were studied. these dimer liquid crystals are known to form an enantiotropic nematic mesophase. In this work, we have determined the volume change as a function of temperature and pressure by using a GNOMIX PVT apparatus. In the V-Tcurves obtaind from isobaris mearements on various pressures, volume changes were observed at the nematic-isotropiz and nematic-crystal phase transitions. The volume changes at the transition exhibit slight odd-even effect with respect to the number of methylene unit n. The values of the (S)v obtained at the NI transition for CBA-9 and -10 were 6.9 and 12.6J/mol k. The valuesof (S)v for the CN transition were estimated on the basis of DSC(differential scanning calorimetry) data: 58.8(CBA-9) and 65.3J/mol k (CBA-10). For both transition, it was found that the correction about the volume change is significant, ranging from 40% to 60% of the total transition entropy observed under constant pressure.

  • PDF

Effect on the Volume Resistivity of Silicone Rubber due toTemperature Variation (온도변화가 실리콘 고무의 체적고유저항에 미치는 영향)

  • Kim, T.Y.;Ku, K.M.;Cho, K.S.;Lee, C.H.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.55-58
    • /
    • 2002
  • In this paper, the volume resistivity properties of silicone rubber investigated due to temperature dependence. And the measurement of volume resistivity is measured from 1, 5 and 10 minutes when the each applied voltage, for example, DC 100[V], 250[V], 500[V] and 1000[V], is applied. according to the step voltage application method. As a result, The volume resistivity is higher high voltage than low voltage at the room temperature, but is higher low voltage than high voltage at high temperature.

  • PDF

Effect of Isothermal annealing on the Corrosion Resistance of an Amorphous Alloy (비정질 합금의 부식저항성에 미치는 열처리의 영향)

  • Shin, Sang-Soo;Lee, Chang-Myeon;Yang, Jae-Woong;Lee, Jae-Chul
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.2
    • /
    • pp.53-57
    • /
    • 2008
  • This study examined the role of excess free volume on the corrosion resistance of an amorphous alloy. Corrosion behaviors were monitored on the amorphous alloys, of which amount of free volume was controlled via the isothermal annealing below the glass transition temperature, using immersion tests and potentiodynamic polarization tests in HCl aqueous solutions. It was found that the corrosion resistance of the amorphous alloy is improved by reducing the amount of excess free volume. The possible reason explaining the experimental result was discussed from the viewpoint of the internal energy associated with the annihilation of excess free volume.

A Study on the Effect of Logistics Performance Index on Korea's Import and Export Cargo (물류성과지표가 우리나라 수출입 물동량에 미치는 영향에 관한 연구)

  • Choong-Bae Lee;Young-Sin Lee
    • Korea Trade Review
    • /
    • v.47 no.4
    • /
    • pp.197-213
    • /
    • 2022
  • This study aims to investigate the relationship between cargo volume and logistics performance index published by World Bank which indicate countries' logistics performance. In this study, the results were derived through panel regression analysis consisting of variables such as gross domestic product, geographical distance, population, and LPI using container export/import volume and bulk export/import volume as dependent variables. As a result of the empirical analysis, it was found that Korea's container volume was affected by the overall level of logistics, in particular, was deeply related to the logistics infrastructure, while bulk volume was not related to the logistics level or was less influential.

The Effect of Oxidizing Agents on Alkaloid Reduction of Tobacco Extract (담배추출물의 알카로이드감소에 미치는 산화제의 영향)

  • 황건중
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.2
    • /
    • pp.33-46
    • /
    • 1982
  • This experiment was carried out for the purpose of reducing alkaloid in reconstituted tobacco sheet and effluent of reconstituted tobacco sheet manufacturing company by treating oxidizing agents such as ozone, sodium hypochlorite, perchloric acid and hydrogen peroxide to tobacco extract created from the manufacturing process of reconstituted tobacco sheet. The effect of alkaloid reduction in tobacco extract by the volume added, time of treatment and pH of oxidizing agents were as follows: 1. When the solid rate of tobacco extract stood at 10 percent, the content of alkaloid, total sugar, total nitrogen and chlorine was 1,600mg/l, 11,000mg/l, 3,200mg/l and 4,000mg/l, respectively. 2. The effect of alkaloid reduction through ozone treatment was in proportion to time of ozone treatment. Alkaloid showed a 31.2 percent reduction under 8 hours' ozone treatment and 0.23g ozone consumed to remove lmg alkaloid. 3. Alkaloid reduction through sodium hypochlorite treatment was influenced by quantity of chlorine in sodium hypochlorite solution. To remove lmg alkaloid, 36.3mg chlorine was used. Reduction of alkaloid was not affected by time of sodium hypochlorite treatment, while showed the best reaction under pH 5-7. 4. The effect of alkaloid reduction by perchloric acid was under the control of the volume added and time of treatment of perchloric acid. The volume of perchloric acid required to remove alkaloid was on the decrease as time of treatment was getting longer. lmg alkaloid was removed by 0.15g perchloric acid under 8 hours' perchloric acid treatment. 5. Alkaloid reduction reacted slowly to the volume added and time of treatment of hydrogen peroxide. Under 8 hours' hydrogen peroxide treatment, it showed maximum removal, registering 10 percent alkaloid reduction.

  • PDF

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.

Partial molal volumes of n-alkylamine hydrochlorides in methanol-water mixtures (메탄올-물 혼합액에서의 n-Alkylamine 염산염의 분 몰랄 부피)

  • Uhm, Tae-Sup;Yoon, Sang-Ki;Lee, Ik-Choon
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.51-59
    • /
    • 1970
  • The apparent molal volumes(${\phi}_v$) of the homologous salts $RNH_3Cl$, where R varies from methyl-($CH_{3^-}$) to n-butyl-(n-$C_4H_{9^-}$) in a series of methanol-water mixtures have been determined at 30$^{\circ}C$ by means of a float method to fifth decimal places down to 0.01 m. The values of ${\phi}_r$ extrapolated to infinite dilution give partial molal volumes $\bar{V}^{\circ}$which varies considerably in accordance with the solvent composition. that is, mole fraction of methanol. The experimental results are discussed in terms of the varying size and charge effect, hydrophobic nature of the solute species, and also the additivity relationship between successive homologous and the structure of the binary solvent. The results indicate that at 0.1 mole fraction methanol the enhanced structuredness of water cause a minimum in the partial molal volumes of cations $\bar{V}^{\circ}_+$, while at 0.4 mole fraction the solvent structure is such that the free volume is a minimum but the effect of electrostriction is a maximum.

  • PDF

Analysis of the dynamic confining effect of CRAC short column under monotonic loadings

  • Wang, Changqing;Xiao, Jianzhuang
    • Structural Engineering and Mechanics
    • /
    • v.74 no.3
    • /
    • pp.351-363
    • /
    • 2020
  • Based on the dynamic tests of recycled aggregate concrete (RAC) short columns confined by the hoop reinforcement, the dynamic failure mechanism and the mechanical parameters related to the constitutive relation of confined recycled aggregate concrete (CRAC) were investigated thoroughly. The fracturing sections were relatively flat and smooth at higher strain rates rather than those at a quasi-static strain rate. With the increasing stirrup volume ratio, the crack mode is transited from splitting crack to slipping crack constrained with large transverse confinement. The compressive peak stress, peak strain, and ultimate strain increase with the increase of stirrup volume ratio, as well as the increasing strain rate. The dynamic confining increase factors of the compressive peak stress, peak strain, and ultimate strain increase by about 33%, 39%, and 103% when the volume ratio of hoop reinforcement is increased from 0 to 2%, but decrease by about 3.7%, 4.2%, and 9.1% when the stirrup spacing is increased from 20mm to 60mm, respectively. This sentence is rephrased as follows: When the stirrup volume ratios are up to 0.675%, and 2%, the contributions of the hoop confinement effect to the dynamic confining increase factors of the compressive peak strain and the compressive peak stress are greater than those of the strain rate effect, respectively. The dynamic confining increase factor (DCIF) models of the compressive peak stress, peak strain, and ultimate strain of CRAC are proposed in the paper. Through the confinement of the hoop reinforcement, the ductility of RAC, which is generally slightly lower than that of NAC, is significantly improved.

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF