• Title/Summary/Keyword: Volume difference

Search Result 2,541, Processing Time 0.027 seconds

Measurement of Volume Fraction of ${\varepsilon}$ Martensite using Specific Volume Difference in Fe-Mn Based Alloys (Fe-Mn 계 합금에서 비부피 차를 이용한 ${\varepsilon}$ 마르텐사이트의 부피분율 측정)

  • Jee, K.K.;Han, J.H.;Jang, W.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.4
    • /
    • pp.211-215
    • /
    • 2003
  • In this work, a new way of measuring the volume fraction of e martensite in Fe-based alloys has been proposed. Since the specific volume of ${\varepsilon}$ martensite, depending on alloy composition, is smaller than that of austenite i.e ${\gamma}$ phase, volume expansion takes place during ${\varepsilon}{\rightarrow}{\gamma}$ reverse transformation. As the amount of the volume expansion is proportional to the product of specific volume difference times the volume fraction of ${\varepsilon}$ martensite, the volume fraction of ${\varepsilon}$ martensite can be calculated by measuring the volume expansion and the specific volume difference. Such a relationship was confirmed in Fe-21Mn and Fe-32Mn-6Si alloys which undergo ${\gamma}{\rightarrow}{\varepsilon}$ martensitic transformation on cooling and by cold rolling, respectively. It was also found that the former has isotropic ${\varepsilon}$ martensite while the latter has anisotropic ${\varepsilon}$ martensite.

The Study of Effectiveness of Volume Mode in Pediatric CT (소아 전산화단층촬영에서 Volume Mode의 유용성 연구)

  • Park, Yun;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.425-431
    • /
    • 2014
  • The purpose of this study is to analyze dose comparison and image quality evaluation according to Volume and Helical mode using ATOM Phantom. It is to actively use the Volume mode in pediatric CT examinations. There was no significant difference with Helical and Volume in the value of Noise, HU, SNR(p>0.05). All dose values was no statistical difference(p>0.05). In the value of DLP and effective dose by part, Volume mode was measured lower than Helical mode. For qualitative analysis, by scan parameter helical mode showed respectively 2.6, 3.3, 4.36 and Volume mode indicated 2.8, 3.64, 4.44 point. Image evaluation for the follow-up, Helical mode and Volume mode were respectively 3.8 and 3.83. In fact, There was no significant difference. In CT scans in children under 5 years, because 640-MDCT Volume scan dose compared with Helical mode is lower and there is no significant difference with two modes in the image quality, 640-MDCT Volume scan is thought to be useful for pediatric CT scans.

Volume difference in upper central incisor preparation according to the changes of restorative design and marginal location (상악 중절치 삭제 시 수복 디자인과 변연부 위치에 따른 부피 변화)

  • Kim, Chong-Hyun;Park, Young-Bum;Kim, Sung-Tae;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the volumetric change of teeth after preparation for various designs and margin locations through Micro CT analysis (Skyscan 1076: SKYSCAN, Konitch, Belgium). Materials and methods: The 36 artificial teeth were used to determine reduction volume of upper central incisor. According to the restorative design these 36 teeth were divided into 4 groups and according to the marginal location each group was divided into 3 subgroups. The volume of unprepared teeth was obtained by using Micro CT and the volume of prepared teeth was obtained in the same method. The CT scanned images before and after preparation were superimposed. Results: The volume difference was significantly increased as follows: traditional laminate veneer < full laminate veneer < all ceramic crown < metal ceramic crown. One-way ANOVA and Tukey multiple comparison analyses were used to analyze the data in this study. In each group the volume difference was significantly increased as follows: 1 mm above CEJ < CEJ < 1 mm below CEJ (P<.05). The % volume difference of all ceramic crown and metal ceramic crown was 31 - 48% and that of laminate veneer was 14 - 30%. The volume difference of the traditional laminate veneer was 1/3 of that of metal ceramic crown. The full laminate (1 mm below CEJ) and all ceramic crown (1 mm above CEJ) showed a similar volume difference. Metal ceramic crown showed 13.7% more volume difference than all ceramic crown. Conclusion: There exists the difference in volumetric change according to designs of restoration and margin locations of preparation.

Some applications for the difference of two CDFs

  • Hong, Chong Sun;Son, Yun Hwan
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.1
    • /
    • pp.237-244
    • /
    • 2014
  • It is known that the dierence in the length between two location parameters of two random variables is equivalent to the difference in the area between two cumulative distribution functions. In this paper, we suggest two applications by using the difference of distribution functions. The first is that the difference of expectations of a certain function of two continuous random variables such as the differences of two kth moments and two moment generating functions could be defined by using the difference between two univariate distribution functions. The other is that the difference in the volume between two empirical bivariate distribution functions is derived. If their covariance is estimated to be zero, the difference in the volume between two empirical bivariate distribution functions could be defined as the difference in two certain areas.

Effect of Gender Difference on the Functional Asymmetry during Preferred Walking Speed

  • Hyun, Seunghyun;Ryew, Checheong
    • International journal of advanced smart convergence
    • /
    • v.9 no.2
    • /
    • pp.49-57
    • /
    • 2020
  • We have not identified on what gender difference during gait at a pace of one's preferred velocity effects on the function of bilateral lower limb. This study was undertaken to investigate a difference of gait strategy by gender during gait at a one's preferred velocity of participants of adult male and female (n=20). Cinematographic data for motion analysis, ground reaction force (GRF) variables, and muscle volume of lower limb were analyzed. Significant difference of variables on movement of center of mass whole body, joint angle and moment of lower limb, and ground reaction force were tested by 2-way ANOVA analysis (P<0.05). Male group showed more muscle volume than female, and both showed more volume in dominant leg than non-dominant. Main effect by bilateral leg during gait showed higher difference in right than left leg in change of vertical position of center of mass (maximal, minimal). Main effect by gender in vertical change of position and velocity of center of mass showed higher difference in male than female (maximal, minimal). Hip joint showed more flexed and extended angle in male than female, and also dorsiflexion of ankle and flexion moment of knee and hip joint showed higher in male than female group. Therefore, this result was assumed that dominant showed furthermore more contribution for propulsive function than non-dominant leg. Gender difference showed in strategy controlling of biomechanical characteristics, and perhaps influenced by muscle volume.

The Seasonal and Interannual Variability of the Volume Transport through the Western Channel of the Korea Strait

  • Kim, Young-Ju;Takikawa, Tetsutaro;An, Hui-Soo;Yoon, Jong-Hwan
    • Journal of the korean society of oceanography
    • /
    • v.39 no.3
    • /
    • pp.155-162
    • /
    • 2004
  • The variation of volume transport during the period from 1965 to 2000 through the western channel of the Korea Strait was estimated by obtaining an relation function between the ADCP volume transport and the geostrophic volume transport estimated by the sea level difference between Pusan and Izuhara. The estimated climatological mean volume transport during past 36 years has seasonal variation with a minimum of 1.15 Sv in February and a maximum of 1.88 Sv in October. The mean volume transport for 36 years is 1.51 Sv. The annual mean volume transport has an interannual variation with a minimum of 1.26 Sv in 1968 and maximum of 1.90 Sv in 1973, with three dominant periods of variations of 14.96 years, 4.96 years and 2.99 years.

A STUDY OF THE CORRELATIONS BETWEEN THE TONGUE AND ORAL CAVITY VOLUME IN THE SKELETAL MANDIBULAR PROGNATHISM (골격성 하악전돌자의 혀와 구강용적의 상관관계에 대한 연구)

  • Choi, Yang-Sook;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.275-282
    • /
    • 1993
  • When mandibular prognathic patients are operated orthognathic surgery which reduce the oral cavity volume, tongue volume should be harmonized with oral cavity volume to be changed because prevent the relapse of malocclusion. To decide the need for tongue resection, the author measured the tongue volume and oral cavity volume with stone model which were taken by impression method and study the difference between the ratio of tongue and oral cavity volume in mandibular prognathic group and normal group. The samples were consisted of four groups, the 40 subjects of the control group, 40 subjects of the experimental group. Each group was subdivided into male and female group respectively. The results were as follows : 1. The tongue volume and oral cavity volume measurements are $20.7cm^3,\;32.7cm^3$ in the control group respectively, and $24.9cm^3,\;42.9cm^3$ in the experimental group respectively. 2. There is no difference in the ratio of the tongue volume to oral cavity volume in control group and experimental group. 3. Correlation coefficients between the tongue volume and oral cavity volume are 0.11, 0.29 in experimental group and control group respectively, and 0.43 in gross total group. 4. The tongue volume of male is larger than female(p<0.05).

  • PDF

A phenomenological approach to suspensions with viscoelastic matrices

  • Tanner Roger I.;Qi Fuzhong
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.149-156
    • /
    • 2005
  • A simple constitutive model for viscoelastic suspensions is discussed in this paper. The model can be used to predict the rheological properties (relative viscosity and all stresses) for viscoelastic suspensions in shear and elongational flow, and the constitutive equations combine a 'viscoelastic' behaviour component and a 'Newtonian' behaviour component. As expected, the model gives a prediction of positive first normal stress difference and negative second normal stress difference; the dimensionless first normal stress difference strongly depends on the shear rate and decreases with the volume fraction of solid phase, but the dimensionless second normal stress difference (in magnitude) is nearly independent of the shear rate and increases with the volume fraction. The relative viscosities and all the stresses have been tested against available experimental measurements.

Analysis of Difference in Growing Stock Volume Estimates by the Changes of Cluster Plot Design and Volume Equation (표본점 설계방법과 적용 단목재적식 변경에 따른 임목축적 차이의 구명)

  • Han, Won-Sung;Kim, Sung-Ho;Kim, Chong-Chan;Shin, Man-Yong
    • Journal of Korean Society of Forest Science
    • /
    • v.99 no.3
    • /
    • pp.304-311
    • /
    • 2010
  • Korea National Forest Inventory System has been adopting different cluster plot design and new equations to estimate growing stock volumes since 2006. These changes have resulted in volume estimations which show some difference from previous ones. This study is to find out the source of such difference. For this, relevant data was collected from 80 plots of 20 cluster samples according to the cluster plot design applied to 4th and 5th National Forest Inventory. Then growing stock volumes were estimated by using current and previous individual tree volume equations respectively. An investigation was made to detect whether such difference in volume estimates was originated from the changes in cluster plot design or from using different volume equations. T-test results showed that the difference from changes in cluster plot design was negligible. Instead, changes in volume equations had statistically significant effects in volume estimation. Since the volume estimation by the 5th National Forest Inventory would bring overestimation by applying different volume equations, all the volume estimations made prior to 2006 would require necessary modifications for international reporting.

Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery (척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가)

  • Dong‑Jin Kang;Geon Oh;Young‑Joo Shin;Jin-Kyu Kang;Jae-Yong Jung;Boram Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.527-533
    • /
    • 2023
  • The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.