• Title/Summary/Keyword: Volume Flow-rate

Search Result 1,180, Processing Time 0.029 seconds

Pollutant Loading Estimate from Yongdam Watershed Using BASINS/HSPF (BASINS/HSPF를 이용한 용담댐 유역의 오염부하량 산정)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.187-197
    • /
    • 2006
  • A mathematical modeling program called Hydrological Simulation Program-FORTRAN (HSPF) developed by the United States Environmental Protection Agency(EPA) was applied to the Yongdam Watershed to examine its applicability for loading estimates in watershed scale. It was run under BASINS (Better Assessment Science for Integrating point and Nonpoint Sources) program, and the model was validated using monitoring data of 2002 ${\sim}$ 2003. The model efficiency of runoff was high in comparison between simulated and observed data, while it was relatively low in the water quality parameters. But its reliability and performance were within the expectation considering complexity of the watershed and pollutant sources and land uses intermixed in the watershed. The estimated pollutant load from Yongdam watershed for BOD, T-N and T-P was 1,290,804 kg $yr{-1}$, 3,753,750 kg $yr{-1}$ and 77,404 kg $yr{-1}$,respectively. Non-point source (NPS) contribution was high showing BOD 57.2%, T-N 92.0% and T-P 60.2% of the total annual loading in the study area. The NPS loading during the monsoon rainy season (June to September) was about 55 ${\sim}$ 72% of total NPS loading, and runoff volume was also in a similar rate (69%). However, water quality was not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. Overall, the BASINS/HSPF was applied to the Yongdam watershed successfully without difficulty, and it was found that the model could be used conveniently to assess watershed characteristics and to estimate pollutant loading in watershed scale.

Effects of Obesity on Pulmonary Functions in Children (소아에서 비만이 운동 전후의 폐활량에 미치는 영향)

  • Park, Seok Won;Kim, Hwang Min;Kim, Jong Soo;Cha, Jae Kuk;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.5
    • /
    • pp.588-595
    • /
    • 2002
  • Purpose : The incidence of obesity has increased in Korea recently. Obesity leads to higher risks of hypertension, hyperlipidemia and insulin resistance. It also leads to risks of respiratory complications. This study was performed to see the effects of obesity on children's pulmonary functions and on developed bronchospasm after exercise loading according to their obesity degrees. Methods : 257 obese children and 150 non-obese children were enrolled. Obese children were divided into 3 groups by the obesity degrees. Pre- and post-exercise loading $FEV_1$(forced expiratory volume at one second), FVC(forced vital capacity) and PEFR(peak expiratory flow rate) were checked in all subjects. The percent predicted values of each parameter was compared according to obesity degrees and the differences between pre-exercise and post-exercise values. Results : The percent predicted value of $FEV_1$, FVC decreased only in the severe obesity group compared with those in the control group. However percent predicted PEFR declined according to obesity degrees. The percent predicted value of $FEV_1$, FVC and PEFR after exercise loading were much lower than those before exercise loading in all groups. Conclusion : As the degree of obesity was higher, the percent predicted value of pulmonary function was lower. And after exercise loading, as the degree of obesity was higher, the reduction of percent predicted value of pulmonary function was larger. Therefore the pulmonary function in obese children must be observed carefully. Further studies on the effects of pulmonary functions in obese children are necessary.

Development and Application of the High Speed Weigh-in-motion for Overweight Enforcement (고속축하중측정시스템 개발과 과적단속시스템 적용방안 연구)

  • Kwon, Soon-Min;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.11 no.4
    • /
    • pp.69-78
    • /
    • 2009
  • Korea has achieved significant economic growth with building the Gyeongbu Expressway. As the number of new road construction projects has decreased, it becomes more important to maintain optimal status of the current road networks. One of the best ways to accomplish it is weight enforcement as active control measure of traffic load. This study is to develop High-speed Weigh-in-motion System in order to enhance efficiency of weight enforcement, and to analyze patterns of overloaded trucks on highways through the system. Furthermore, it is to review possibilities of developing overweight control system with application of the HS-WIM system. The HS-WIM system developed by this study consists of two sets of an axle load sensor, a loop sensor and a wandering sensor on each lane. A wandering sensor detects whether a travelling vehicle is off the lane or not with the function of checking the location of tire imprint. The sensor of the WIM system has better function of classifying types of vehicles than other existing systems by detecting wheel distance and tire type such as single or dual tire. As a result, its measurement errors regarding 12 types of vehicle classification are very low, which is an advantage of the sensor. The verification tests of the system under all conditions showed that the mean measurement errors of axle weight and gross axle weight were within 15 percent and 7 percent respectively. According to the WIM rate standard of the COST-323, the WIM system of this study is ranked at B(10). It means the system is appropriate for the purpose of design, maintenance and valuation of road infrastructure. The WIM system in testing a 5-axle cargo truck, the most frequently overloaded vehicle among 12 types of vehicles, is ranked at A(5) which means the system is available to control overloaded vehicles. In this case, the measurement errors of axle load and gross axle load were within 8 percent and 5 percent respectively. Weight analysis of all types of vehicles on highways showed that the most frequently overloaded vehicles were type 5, 6, 7 and 12 among 12 vehicle types. As a result, it is necessary to use more effective overweight enforcement system for vehicles which are seriously overloaded due to their lift axles. Traffic volume data depending upon vehicle types is basic information for road design and construction, maintenance, analysis of traffic flow, road policies as well as research.

  • PDF

Determination and Survey of Fluoroquinolones Residue in Chicken Muscle by HPLC with Fluorescence Detector (액체크로마토그래피-형광검출기를 이용한 닭고기 중 플루오로퀴놀론계 항균물질 정량분석 및 잔류조사)

  • 박은정;임지흔;이성모
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.1
    • /
    • pp.12-18
    • /
    • 2004
  • Ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin in chicken muscle were seperated by liquid extraction and determined with high performance liquid chromatography (HPLC) with fluorescence detector. Analysis was carried out using following conditions; Cl8 column (250${\times}$4.6 mm i.d. 5 ${\mu}{\textrm}{m}$ particle size), mobile phase composed of D.W. (containing 0.4% triethylamine and phospholic acid): methanol : acetonitrile (800:100:100, v/v/v), isocratic pump at a flow rate of 1.0 $m\ell$/min and 50 ${mu}ell$ of injection volume, fluorescence detector with EX278 nm/EM.456 nm. The calibration curves of four fluoroquinolones showed linearity (${\gamma}$$^2$$\geq$0.999) at concenration range of 0.025-0.6 $\mu\textrm{g}$/ml. The recoveries in fortified chicken muscle represented more than 80% with low coefficient of variation (〈10%) for concentration range of four fluoroquinolones. The detection limits for ofloxacin, norfloxacin, ciprofloxacin, and enrofloxacin were 23.5, 3.4, 3.0 and 2.5 ng/g in chicken muscle, respectively. We also monitored fluoroquinolones residue in muscle of chickens (broiler 1:227, Korean native chicken 219, laying chicken 77) using EEC-4-plate screening and HPLC conformation methods. Ten(broiler 5, Korean native chicken 5) out of the fifteen samples which were positively detected by EEC-plate screening method from 1,523 chicken meat were confirmed with ciprofloxacin and enrofloxacin by HPLC. The ranges of residual concentration were 0-0.12 ppm for ciprofloxacin and 0.01-6.79 ppm for enrofloxacin. In conclusion, our method could be applied effectively to determine four fluoroquinolones residues in chicken meat, and further survey for fluoroquinolones residue in chicken meat are needed for more effective control of fluoroquinolones used in livestock.

Evaluating Stabilization Efficiency of Coal Combustion Ash (CCA) for Coal Mine Wastes: Column Experiment (석탄회를 이용한 석탄광산 폐기물의 안정화 효율성 평가: 컬럼 시험)

  • Oh, Se-Jin;Kim, Sung-Chul;Ko, Ju-In;Lee, Jin-Soo;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1071-1079
    • /
    • 2011
  • In this study, coal combustion ash (CCA) was evaluated for its stabilization effect on acidic mine waste with column experiment. Total of six treatments were installed depending on mixing ratio between coal wastes and CCA (0, 20, 40%) and mixing method (completely mixing and layered). Artificial acidic rain (pH 5.6) was used for feeding solution with flow rate of $0.05mL\;min^{-1}$. Result showed that higher pH of leachate was observed as more CCA was mixed. The highest pH in leachate was measured when 40% of CCA was mixed with coal waste (pH of 5.8). Also, complete mixing with CCA and coal waste was more effective to increase the pH of leachate than layered treatment. Regarding the reduction of soluble Fe amount, the highest efficiency (78%) was observed when 20% of coal ash was completely mixed with mine waste. Based on those result, optimum mixing ratio of coal ash with mine waste can be ranged 20-40% depending on environmental circumstances in the field.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Development of Heated-Air Dryer for Agricultural Waste Using Waste Heat of Incineration Plant (소각장 폐열을 활용한 농업폐기물 열풍 건조장치 개발)

  • Song, Dae-Bin;Lim, Ki-Hyeon;Jung, Dae-Hong
    • Journal of agriculture & life science
    • /
    • v.53 no.5
    • /
    • pp.137-143
    • /
    • 2019
  • To manufacturing of solid fuel by reuse of the wastes, the drying unit which have 500 kg/hr of drying capacity was developed and experimentally evaluate the performance. The spinach grown in Nam-hae island were used for the experiments and investigated of the heated-air drying characteristics as the inlet amount of raw materials, raw material stirring status, conveying type and drying time. The drying air heated by the energy derived from the steam which is supplied from the incineration plant. The moisture contents of raw materials were measured 85.65%. The inlet flow rate of drying air made a difference as the depth of the raw materials loaded on the drying unit and temperature has showed 108~144℃. The drying speed of the mixed drying more than doubled as that of non mixed drying under the same drying type, inlet amount, drying time and drying air temperature. In each experiment, the drying capacity have showed over 500 kg/hr. A drying efficiency of the ratio of drying consumption energy to input energy was 33.46%, lower than the average of 57.76% for the 157 conventional dryers. Because developed dryer must have a drying time of less than one hour, it is considered that the dry efficiency has been reduced due to the loss of wind volume during drying. If waste heat from incineration plant is used as a direct heat source, the dry air temperature is expected to be at least 160℃, greatly improving the drying capacity.

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

A Comparison of Tiotropium 18㎍, Once Daily and Ipratropium 40㎍, 4 Times Daily in a Double-Blind, Double-Dummy, Efficacy and Safety Study in Adults with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자에서 Tiotropium 1일 1회, 1회 18㎍ 요법과 Ipratropium 1일 4회, 1회 40㎍ 요법의 치료효과 및 안전성 비교)

  • Kim, Seung Joon;Kim, Myung Sook;Lee, Sang Haak;Kim, Young Kyoon;Moon, Hwa Sik;Park, Sung Hak;Lee, Sang Yeub;In, Kwang Ho;Lee, Chang Youl;Kim, Young Sam;Kim, Hyung Jung;Ahn, Chul Min;Kim, Sung Kyu;Kim, Kyung Rok;Cha, Seung Ick;Jung, Tae Hoon;Kim, Mi Ok;Park, Sung Soo;Choi, Cheon Woong;Yoo, Jee Hong;Kang, Hong Mo;Koh, Won Jung;Ham, Hyoung Suk;Kang, Eun Hae;Kwon, O Jung;Lee, Yang Deok;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun;Shin, Won Hyuk;Kwon, Sung Yeon;Kim, Woo Jin;Yoo, Chul Gyu;Kim, Young Whan;Shim, Young Soo;Han, Sung Koo;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Mi Hye;Lee, Won Yeon;Yong, Suk Joong;Shin, Kye Chul;Choi, Byoung Whui;Oh, Yeon Mok;Lim, Chae Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Jung, Sung Soo;Kim, Ju Ock;Ko, Young Chun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.498-506
    • /
    • 2005
  • Background : This study compared the bronchodilator efficacy and safety of tiotropium inhalation capsules ($18{\mu}g$ once daily) with a ipratropium metered dose inhaler (2 puffs of $20{\mu}g$ q.i.d.) in patients with chronic obstructive pulmonary disease (COPD). Method : After the initial screening assessment and a two-week run-in period, patients received either tiotropium $18{\mu}g$ once daily or ipratropium $40{\mu}g$ four times daily over a period of 4 weeks in a double blind, double dummy, parallel group study. The outcome measures were the lung function, the daily records of the peak expiratory flow rate (PEFR), the patients' questionnaire, and the use of concomitant salbutamol. The forced expiratory volume in one second ($FEV_1$) and the forced vital capacity (FVC) were measured 5 minutes before inhalation, and 0.5, 1, 2 and 3 hours after inhaling the study drug on days 0, 14 and 28. Result : In 16 centers, 134 patients with a mean (SD) age of 66 (7) years and a predicted $FEV_1$ of 42 (12)% were analyzed. The trough $FEV_1$ response was significantly higher in the tiotropium group than in the ipratropium group after a four-week treatment period. The weekly mean morning PEFR of the tiotropium group was consistently higher than that of the ipratropium group during the 4-week treatment period with differences ranging from 12.52 to 13.88 l/min, which were statistically significant. Tiotropium was well tolerated by the COPD patients during the 4-week treatment period and had a similar safety profile to ipratropium. Conclusion : This study shows that tiotropium administrated once daily has a superior bronchodilator effect with a similar safety profile in treating COPD patients compared with ipratropium, inhaled four times daily.