• Title/Summary/Keyword: Volume Efficiency

Search Result 2,126, Processing Time 0.025 seconds

Analysis for Efficiency in the Oyster, Mussel Aquaculture Household using SFA (SFA를 이용한 굴, 홍합 양식어가의 효율성 분석)

  • Kim, Tae-Hyun;Park, Cheol-Hyung
    • The Journal of Fisheries Business Administration
    • /
    • v.47 no.2
    • /
    • pp.1-14
    • /
    • 2016
  • This study applied the Stochastic Frontier Analysis to estimate which independent variable affects to efficiency of aquaculture household. This study used wage and facility scale as input variables, sales volume as an output variable to estimate efficiency. Also, the study used region, species, water quality to estimate technical inefficiency factors of the model. The data used for this study were obtained by the operating costs survey using 1:1 interview method. The study selected translog production model with technical inefficiency term estimated as half-normal distribution. In addition, the study used pearson and spearman correlation coefficient among efficiency estimating models. Also, the study analysed differences among estimated efficiencies through t-test, and showed us 0.1793 in species, 0.4677 between Geojae and Masan.

Energy Efficiency of Fluidized Bed Drying for Wood Particles

  • Park, Yonggun;Chang, Yoon-Seong;Park, Jun-Ho;Yang, Sang-Yun;Chung, Hyunwoo;Jang, Soo-Kyeong;Choi, In-Gyu;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.821-827
    • /
    • 2016
  • This study evaluates the economic feasibility of industrializing fluidized bed dryer for wood particles. The theoretically required heat energy and energy efficiency were evaluated using a pilot scale fluidized bed dryer. When Mongolian Oak wood particles with 50% initial moisture content were dried in the fluidized bed dryer with air of $70^{\circ}C$ air circulating at 1.1-1.3 m/s for 30 minutes, the total theoretically required heat energy was 2,177 kJ. Of this, 1,763 kJ (approximately 81.0%) was used to heat the air flowing in from outside the dryer and 386 kJ (approximately 17.7%) was used to heat and remove water from the wood particles. Actual energy consumed was 7,560 kJ, giving energy efficiency of 28.8%. Thus, to industrialize a drying method such as fluidized bed drying, where the dryer volume is significantly larger than the volume of wood particles, it is necessary to minimize energy loss and maximize energy efficiency by designing the dryer size considering the amount of wood particles and choosing a suitable air circulation rate.

Manufacture of a Gamma-ray Source using the Neutron Activation and Determination of a HPGe Detector Efficiency (중성자 방사화법을 이용한 감마선원 제조 및 HPGe 검출기 효율 결정)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • In order to save time and money needed in the purchase commonly used gamma-ray standard sources, a new radioactive standard source was manufactured by the neutron activation of some regent in the research reactor HANARO. The source was manufactured with an aqueous solution by mixing and dissolving the irradiated reagents. The manufactured source was compared with a commercial standard source. It was confirmed that it could be used as an efficiency calibration source. Also, in order to compare the variation of efficiency due to the volume difference for various containers used in radioactivity assay, the efficiency variation as a function of sample volume was investigated.

Performance Analysis of Ejector-Pump Thermal Energy Conversion System Using Various Working Fluids (이젝터-펌프 온도차발전시스템의 작동유체별 성능분석)

  • Yoon, Jung-In;Seol, Sung-Hoon;Son, Chang-Hyo;Choi, Kwang-Hwan;Kim, Young-Bok;Lee, Ho-Saeng;Kim, Hyeon-Ju;Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.87-92
    • /
    • 2016
  • This research dealt with performance characteristics of OTEC system applying an ejector and additional pump. Each system using five kinds of working fluids was analyzed, and primary parameters with respect to entrainment ratio were examined: Turbine gross power, evaporation capacity, pump work, efficiency and volume flow ratio. The primary results were as following. The efficiency of ejector-pump OTEC system was dependent on entrainment of the ejector. The degree of efficiency change was different from applied working fluid, and amount of pump work was turned out to be primary factor affected system efficiency. Meanwhile, optimized entrainment ratio was different from applied working fluid since their different vapor density. System efficiency at optimized entrainmet ratio of each working fluid was around 5%, showing minor difference each other.

Design and implementation of photopolymer-based holographic volume grating couplers for optical interconnection (광연결을 위한 포토폴리머형 홀로그래픽 부피격자 커플러의 설계 및 구현)

  • Lee, Kwon-Yeon;Jeung, Sang-Huek;Cho, Byung-Mo;Son, Myung-Sik;Jeon, Seok-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.261-271
    • /
    • 2008
  • Holographic volume grating couplers (VGCs) are become increasingly attractive device for the application of optical interconnects because of their higher preferential coupling, dry fabrication processing, compact, and low cost. In this paper, the analysis, design, and implementation of the waveguide-imbedded input-output VGC with $45^{\circ}$ grating slant angle using holographic photopolymer(Dupont HRF600-20) for guided-wave optical interconnection applications, are presented. To show the usefulness of the proposed VGC, we fabricated the VGCs operating at 632.8nm and 1550nm wavelengths and its results are presented. The measured input coupling efficiency of the single VGC with $0.5{\mu}m$ grating period at 632.8nm wavelength is above 86.6% for TE-polarization. The input coupling efficiency of the $1\times2$ VGC with $0.73068{\mu}m$ grating period at 1550nm wavelength is about 90.8%.

  • PDF

Positron Emission Computed Tomographs and Image Reconstruction Methods (PET 장치와 화상 재구성법)

  • Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.5-11
    • /
    • 1999
  • This paper reviews recent major activities on instrumentation and methodology of PET. The performance of the PET instrumentation can be expressed by four physical characteristics, 1) spatial resolution, 2) coincidence resolving time, 3) energy resolution, and 4) detection efficiency. The physical and technical aspects of PET systems are briefly discussed along with these characteristics. Toward high resolution PET the recent trend has been to design multiple rings of densely packed detector arrays with scintillators. In order to satisfy the sampling requirement in reconstruction, continuous detector units has been developed. Iterative image reconstruction algorithms have received considerable attention for improvement of both the sampling requirement and image quality toward the stationary PET. Better resolving time improves the maximum true coincidence rate, which is also increased with more detectors placed in coincidence with each other. It suggests that volume PET is promising for enhancement of detection efficiency. The scattered coincidence event rate may be reduced by using detectors with better energy resolution. The use of interplane septa, however, takes over improvement of energy resolution in 2D PET. Energy resolution becomes an important factor for image quality under the condition of septa removal such as volume PET. Toward full utilization of emitting photons, 3D reconstruction incorporating oblique rays has been studied, and volume reconstruction algorithms have been developed. Practical volume PET systems impose heavy burden not only to detector sets and coincidence circuits, but also to computers in the memory requirements and the data processing. In conclusion, there have been many ingenious methods in development of PET instrumentation, which are based on unique capability of PET. They will be expected to overcome technical limitations, and to approach the fundamental limits.

  • PDF

A Rapid Preconcentration Method Using Modified GP-MSE for Sensitive Determination of Trace Semivolatile Organic Pollutants in the Gas Phase of Ambient Air

  • He, Miao;Xu, Qingjuan;Yang, Cui;Piao, Xiangfan;Kannan, Narayanan;Li, Donghao
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2995-3000
    • /
    • 2014
  • A sensitive concentration method utilising modified gas-purge microsyringe extraction (GP-MSE) was developed. Concentration (reduction in volume) to a microlitre volume was achieved. PAHs were utilised as semivolatile analytes to optimise the various parameters that affect the concentration efficiency. The injection rate and temperature were the key factors that affected the concentration efficiency. An efficient concentration (75.0-96.1%) of PAHs was obtained under the optimised conditions. The method exhibited good reproducibility (RSD values that ranged from 1.5 to 9.0%). The GP-MSE concentration method enhances the volume reduction (concentration factor), leading to a low method detection limit ($0.5-15ngL^{-1}$). Furthermore, this method offers the advantage of small-volume sampling, enabling even the detection of diurnal hourly changes in the concentration of PAHs in ambient air. Utilising this method in combination with GC-MS, the diurnal hourly flux of PAHs from the gas phase of ambient air was measured. Indeed, the proposed technique is a simple, fast, low-cost and environmentally friendly.

Enhancing the Reproducibility of a Photoacoustic Signal Using a Minimum-volume Cell (최소 부피 광음향 셀의 광음향 신호 재현성 향상에 관한 연구)

  • Kim, Kyong-Seok;Lee, Kew-Seung;Ahn, Hong-Gyu;Lee, Eung-Jang;Kim, Dae-Kyu;Park, Seung-Han
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.2
    • /
    • pp.77-82
    • /
    • 2011
  • Reproducibility obtained by a minimum-volume cell for photoacoustic (PA) signals is strongly dependent upon the sealing materials and sealing efficiency. Therefore, we have proposed, designed, and constructed an apparatus to enhance the sealing efficiency, and we have examined the reproducibility of amplitude and phase of PA signals with a minimum-volume cell. In particular, we have measured the PA signal as a function of modulation frequency for various rubber O-rings by using our apparatus. The results show that a silicon rubber O-ring can improve the reproducibility of the PA signal and phase by up to 53.4% and 80.4%, respectively, compared to that obtained by using the conventional sealing material, vacuum grease.

Influence on the Thermal Environment by Change of Indoor-air Volume of Plastic Greenhouse with Hot Air Heating Systems (온풍난방을 채용한 3연동 플라스틱 하우스의 실내공기용적 변화가 하우스 온열환경에 미치는 영향)

  • Jeon, Sam-Chae;Li, Chang-Su;Na, Su-Yeun;Huh, Jong-Chul;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Relatively being economical in installation and easy in operation, hot-air heating system has been generally used in greenhouse for heating system regardless of high cost in maintenance and uneven distribution of air temperature. Therefore to overcome the disadvantages in maintenance and in distribution of air temperature and to improve efficiency of heating system, this experimental study is performed. This experimental study aims to improve the character of uneven temperature distribution in vertical direction and to reduce energy consumption for heating in a greenhouse. The experiment had been performed to investigate change of thermal environment and effects on reducing energy consumption for heating in greenhouse by additional surface insulation and reduction of indoor-air volume that come by installing transparent vinyl membranes with different height in each house. The results show that there is a wide difference in oil-energy consumption between houses according to condition of surface insulation and change of indoor-air volume. Furthermore, the results show that the efficiency of dual surface is higher than that of change of indoor-air volume in terms of energy saving.

Applying Fishing-gear Simulation Software to Better Estimate Fished Space as Fishing Effort

  • Lee, Ji-Hoon;Lee, Chun-Woo;Choe, Moo-Youl;Lee, Gun-Ho
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.2
    • /
    • pp.138-147
    • /
    • 2011
  • Modeling fishing-gear systems is essential to better understand the factors affecting their movement and for devising strategies to control movement. In this study, we present a generalized mathematical modeling methodology to analyze fishing gear and its various components. Fishing gear can be divided into a finite number of elements that are connected with flexible lines. We use an algorithm to develop a numerical method that calculates precisely the shape and movement of the gear. Fishinggear mathematical models have been used to develop software tools that can design and simulate dynamic movement of novel fishing-gear systems. The tool allowed us to predict the shape and motion of the gear based on changes in operation and gear design parameters. Furthermore, the tool accurately calculated the swept volume of towed gear and the surrounding volume of purse-seine gear. We analyzed the fished volume for trawl and purse-seine gear and proposed a new definition of fishing effort, incorporating the concept of fished space. This method may be useful for quantitative fishery research, which requires a good understanding of the selectivity and efficiency of fishing gear used in surveys.