• Title/Summary/Keyword: Volume Calculation

Search Result 803, Processing Time 0.031 seconds

Segmentation and Volume Calculation through the Analysis of Blurred Gray Value from the Brain MRI (뇌의 MR 영상에서 번짐 현상의 명암 값 분석을 통한 백질과 회백질의 추출 및 체적 산출)

  • Sung, Yun-Chang;Yoo, Seung-Wha;Song, Chang-Jun;Park, Jong-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.815-826
    • /
    • 2000
  • This study is for the segmentation and volume calculation of the white matter and gray matter from brain MRI. In general, the volume of white and gray matter is reduced by contraction of each components in the case of mental retardation which are Alzheimer's disease and Down's syndrome. As results, it is useful for diagnostic and early detection for various mental retardation through the tracing of variation for its volume from the brain MRI. But, until now, it was very difficult to calculate the partial volume of each components existing in some thickness, because MR image was represented by single gray value after scanning by MR scanner. Accordingly, new segmentation algorithm proposed in this paper is to calculate the partial volume of the white and gray matter existing in some thickness through the analysis of the blurred gray value, and is to determine the threshold for segmentation of white and gray matter, and is to calculate the volume of each segmented component. And finally, proposed algorithm was applied the models which was created manually, and then acquired results was compared with that of original model.

  • PDF

A study on temporal accuracy of OpenFOAM

  • Lee, Sang Bong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2017
  • Cranke-Nicolson scheme in native OpenFOAM source libraries was not able to provide 2nd order temporal accuracy of velocity and pressure since the volume flux of convective nonlinear terms was 1st accurate in time. In the present study the simplest way of getting the volume flux with 2nd order accuracy was proposed by using old fluxes. A possible numerical instability originated from an explicit estimation of volume fluxes could be handled by introducing a weighting factor which was determined by observing the ratio of the finally corrected volume flux to the intermediate volume flux at the previous step. The new calculation of volume fluxes was able to provide temporally accurate velocity and pressure with 2nd order. The improvement of temporal accuracy was validated by performing numerical simulations of 2D Taylor-Green vortex of which an exact solution was known and 2D vortex shedding from a circular cylinder.

Design remaining capacity calculation system of a nickel-cadmium battery by using fuzzy logic (퍼지로직을 이용한 니켈-카드뮴 축전지의 잔존용량 산출 알고리즘 제안)

  • Jang, Woong-Sung;Jeon, Sun-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.355-357
    • /
    • 2004
  • In this paper, to calculate accurate remaining volume, it presents how to figure out nickel-cadmium battery algorithm. A nickel-cadmium battery has widely been used in industrial field and to military. Recent high demands on the battery caused 'How to calculate accurate remaining volume is very important task to be solved. In this paper, it says it is useful using the terminal voltage change of the resistance that can be connected with the battery and the differentiation of the terminal voltage to calculate remaining volume of nickel-cadmium battery. And these can be used for volume inference data so that it is fuzzy based system which can be helpful to inference the remaining volume by the resistance of terminal voltage change. Because of electrochemical complexity, the volume calculating system is inferencing undirectly by experimentally built DB where as current the existing volume models are suffering to be adapted.

  • PDF

A Study on the Earthwork Calculation for Reclamation (埋立을 위한 土工量 계산에 관한 硏究)

  • Mun, Du-Yeoul
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.61-70
    • /
    • 1995
  • The purpose of this paper is to calculate the excavation volume of unequal interval grid using nonlinear boundary in eathwork volume determination for reclamation of the foreshore. A congruence area formula by first and third equation is compared with trapezoidal, simpson formulas to earthwork volume. And nonlinear spot level method of unequal interval grid is compared with linear and nonlinear spot level method of equal interval grid excavation volume. As a result algorithm of derived area and volume formula should provide a better accuracy than linear and nonlinear spot level currently in use. Practical application of each method to the excavation volume is illustrated by digital elevation model of aerial photogrammetry and model test of aquarium.

  • PDF

Accuracy Improvements of DAM-Reservoir Storage Volume Estimation based on GIS (GIS기반에서 댐 저수량 산정의 정확도 향상)

  • Jeong, InJu;Moon, DooYoul;Jung, BeomSeok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.2
    • /
    • pp.136-144
    • /
    • 2005
  • GIS analyzes various topographic feature in three dimensions using triangulated irregular network (TIN). This paper proposed a method that can analyze topographic features effectively in three dimensions. Method developed in this study can calculate earth-volume, the inundation volume, storage volume etc, effectively. We could reduce error than existing volume calculation methods in computing volume in addition to water level's change about each. Also, the develop method can improve accuracy in measuring the storage of reservoirs. Main result of this paper id to develop a efficient calculation method using contour and elevation data on digital map.

  • PDF

Numerical Simulation of Surface Tension-Dominant Multiphase Flows by Using Volume-Capturing Method and Unstructured Grid System (비정렬격자계와 체적포착법을 사용한 표면장력이 지배적인 다상유동 수치해석)

  • Myong, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.7
    • /
    • pp.723-733
    • /
    • 2011
  • A numerical method of the CSF(Continuum Surface Force) model is presented for the calculation of the surface tension force and implemented in an in-house solution code(PowerCFD). The present method(code) employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with volume capturing method(CICSAM) in a volume of fluid(VOF) scheme for phase interface capturing. The application of the present method to a 2-D liquid drop problem is illustrated by an equilibrium and nonequilibrium oscillating drop calculation. It is found that the present method simulates efficiently and accurately surface tension-dominant multiphase flows.

Phase Identification of Nano-Phase Materials using Convergent Beam Electron Diffraction (CBED) Technique

  • Kim, Gyeung-Ho;Ahn, Jae-Pyoung
    • Applied Microscopy
    • /
    • v.36 no.spc1
    • /
    • pp.47-56
    • /
    • 2006
  • Improvements are made to existing primitive cell volume measurement method to provide a real-time analysis capability for the phase analysis of nanocrystalline materials. Simplification is introduced in the primitive cell volume calculation leading to fast and reliable method for nano-phase identification and is applied to the phase analysis of Mo-Si-N nanocoating layer. In addition, comparison is made between real-time and film measurements for their accuracy of calculated primitive cell volume values and factors governing the accuracy of the method are determined. About 5% accuracy in primitive cell determination is obtained from camera length calibration and this technique is used to investigate the cell volume variation in WC-TiC core-shell microstructure. In addition to chemical compositional variation in core-shell type structure, primitive cell volume variation reveals additional information on lattice coherency strain across the interface.

Calculation of DC resistance of strand-to-strand joints for KSTAR (KSTAR 용 소선-소선 접합부의 직류저항 계산)

  • Ho-Jin Lee;Hyun-Il Nam;Ki-Baik Kim;Gye-Won Hong
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.104-110
    • /
    • 2001
  • Since the strand-to-strand type joint far CICC (Cable-In-Conduit Conductor) is small in size and has low DC resistance, it is expected to be useful type fur a superconducting magnet system which had a compact structure like the KSTAR (Korea Superconducting Tokamak Advanced Research) coil system. The DC resistance is changed according to the distribution patterns of strands in cables connected together in the joint. A commercial code was used for the calculation of the DC resistance. With the decrease of outer diameter of the Joint, Which means the increase of strand volume fraction in the joint, the calculated DC resistance decrease rapidly and non-lineally. The variation of resistance depends mainly on the volume fraction of solder which has higher resistivity than copper. The resistance decrease inversely with the increase of the length of the joint. The resistance increase with increase of number of triplets in each stack contacted with that of another terminal cable. In case of the strand-to-strand joint that has 62mm of outer diameter, 52mm of inner diameter, 100mm of overlap length, and four triplets in each stack, the calculated DC resistance is less than 1 n-Ohm.

  • PDF

Studies on the Estimation of Stand Volume Increment in the Jack Pine (Pinus banksiana Lamb.) in Artificial Forest (방크스소나무 인공림(人工林) 임분(林分)의 재적생장(材積生長) 추정(推定)에 관(關)한 연구(硏究))

  • Lee, Jong-Lak
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.414-421
    • /
    • 2000
  • This study was carried out for the artificial forest stand of 23 years old jack pine(Pinus banksiana Lamb.) in Soheul-myun, Pochun-kun, Kyunggi province of Korea. The objectives of this study were to investigate the stand volume increment and the rate of stand volume, and were to investigate present stand volume to determine annual cutting volume for keeping stand volume to an ideal level for investigated jack pine stand. For a reasonable calculation of stand volume increment, diameter of breast height(DBH), tree height, bark width, and core length for the last 10 years for respective sampling plots were measured. By using these measurements annual diameter increment in DBH class, stand volume increment of 95% confidence interval and tree height curve equation were calculated. The tree height value was derived from the tree height curve equation. Calculation of tree volume by using the tree volume table was made by conferring the tree height value. The summarized results for investigated jack pine trees were having 7.7% annual stand volume increment with 6.1% estimated error. The total stand volume per ha was $79.58m^3$, accordingly the annual stand volume increment was $6.13m^3$ per ha, and the 95% confidence intervals range from 5.77 to $6.51m^3$.

  • PDF

An Analysis of Cost and Profit of a Nursing Unit using Performance-Based Costing: Case of a General Surgical Ward in a General Hospital (시행기준 원가계산을 적용한 간호단위 원가 및 수익 인식에 관한 연구: 1개 종합병원 일반외과병동 사례를 중심으로)

  • Lim, Ji-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.161-171
    • /
    • 2008
  • Purpose: The aim of this study was to analysize net income of a surgical nursing ward in a general hospital. Method: Data collection and analysis was conducted using a performance-based costing and activity-based costing method. Result: Direct nursing activities in the surgical ward were 68, indirect nursing activities were 10. The total cost volume of the surgical ward was calculated at \119,913,334.5. The cost volume of the allocated medical department was \91,588,200.3, and the ward consumed cost was \28,325,134.2. The revenue of the surgical nursing ward was \33,269,925.0. The expense of a surgical nursing ward was \28,325,134.2. Therefore, the net income of a surgical nursing ward was \4,944,790.8. Conclusion: We suggest that to develop a more refined nursing cost calculation model, a standard nursing cost calculation system needs to be developed.