Standardization of Critical Temperature Measurement based on IEC International Standard

  • Lee, Kyu-Won;Kim, Kyu-Tae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.123-127
    • /
    • 2003
  • For disseminating a ney IEC international standard of critical trmperature of NbTi,Nb$_3$Sn and Bi-2223 Composite Suterconductors, we develpted a measuring system and studied standardization of test method. The measuring system consisted of cryogenic reservoir, base plate, thermometer, voltmeter and current source. Various specimens of the Nbti, Nb$_3$Sn and Bi-2223 composite superconductors were tested using this system for measuring their critical temperatures. After measuring the resistance-temperature relation, the data were compensated with thermoelectric voltages for NbTi Nb$_3$Sn specimens. NbTi specimens showed 9.2 K ~ 9.5 K of transition temperature and Nb$_3$Sn specimen showed about 18 K. Bi-2223 specimens showed 104 K ~ 107 K of transition temperature.

Traceable AC Voltage and Current Measurements Using Digital Sampling Technique (디지털 샘플링 방법을 사용한 교류전압과 전류의)

  • Wijesinghe, W.M.S.;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.686_687
    • /
    • 2009
  • The traceability maintenance system for the AC voltage and current has been developed at the frequency range of 20 Hz to 100 Hz without using any compensation technique which is used at thermal converter (TC) ac-dc transfer system at low frequencies. The system uses a digital voltmeter (DVM) as a data acquisition system of the input waveform and stored data in memory. The developed algorithm acquires and processes the sampling data to calculate the root mean square (rms) value of the input voltage of DVM which operates at DC 10 V range for better accuracy. The best uncertainty of the AC voltage measurements is $3 {\mu}V/V$ within the frequency range. The best uncertainty of the AC current measurements is better than the $5 {\mu}A/A$ and mainly depend on the current to voltage converter, ac-dc current shunt or Current Transformer (CT), used for the measurement

  • PDF

DEVELOPMENT OF ON-THE-FLY(OTF) OBSERVATION METHOD FOR SEOUL RADIO ASTRONOMY OBSERVATORY(SRAO) 6-METER TELESCOPE (서울전파천문대(SRAO) 6M 망원경의 ON-THE-FLY 관측 시스템 구축)

  • Kang, Hyun-Woo;Byun, Do-Young;Park, Yong-Sun
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.73-83
    • /
    • 2005
  • On-The-Fly (OTF) observation method is developed for the efficient use of 6 M radio telescope at Seoul Radio Astronomy Observatory (SRAO). This technique, in which data and information of antenna position are recorded synchronously while driving a telescope regularly and rapidly across a field, provides more efficient use of telescope time and better calibration of the acquired data than the traditional point-to-point observation method does. For the realization of the method, we (1) added RT-Linux modules to the existing operating system, (2) replaced digital voltmeter with voltage-to-frequency converter, and (3) modified many SRAO observation programs. By observing Moon and G78.2+2.7 using this method and comparing them with previous observations, we verify the successful operation and efficiency of the OTF observation mode.

Plasma Uniformity Analysis of Inductively Coupled Plasma Assisted Magnetron Sputtering by a 2D Voltage Probe Array

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • v.23 no.4
    • /
    • pp.161-168
    • /
    • 2014
  • A real-time monitoring of immersed antenna type inductively coupled plasma (ICP) was done with a homemade 2 dimensional voltage probe array to check the uniformity of the plasma. Measured voltage values with a high impedance voltmeter are close to the floating potential of the plasma. As the substrate carrier was moving into a magnetron sputtering plasma diffusive from a $125mm{\times}625mm$ size cathode, measured results showed reliably separation of plasma into the upper and lower empty space over the carrier. Infra red thermal imaging camera was used to observe the cross corner effect in situ without eroding a target to the end of the usage. 3 dimensional particle trace model was used to analyze the magnetron discharge's behavior.

The Study on the Voltage Improvement in Distribution Line(I) (배전선로(配電線路)의 전압개선(電壓改善) 대책(對策)에 관한 연구(硏究)(I))

  • Kim, Ho-Yong;Rho, Dae-Sook;Son, Soo-Kook;Kim, Sang-Jun;Son, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.888-891
    • /
    • 1988
  • Recently, with the expansion of electronic equipment and computer facilities, good quality of services is required. This paper describes how to improve distribution system voltage by the Tap position seletion of P. Tr, by the decision of the optimal sending voltage in substation and we also developed three phase load flow program in distribution system. Besides we have developed the digital recording voltmeter that will be utilized with personal computer system. This meter will be useful, economical and powerful.

  • PDF

Characteristics of Static Electrification on Insulation Oil Aging (변압기 절연유의 열화에 따른 대전특성)

  • Kweon, Dong-Jin;Kim, Han-Sang;Chong, Yong-Ki;Kim, Kyoung-Wha;Kim, Du-Seok;Kwak, Hee-Ro;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1615-1618
    • /
    • 1994
  • This paper studied the streaming electrification of the U.H.V. transformer with the spinning cylinder system, and compared and analyzed it with the conventional forced flowing system which uses a pump or gas for oil flowing. Also, accumulated surface voltage in its electrified material was measured with the electrostatic voltmeter, and the effect of insulation oil aging was measured. As results, in spinning cylinder system, characteristics of the streaming electrification to its rotational speed and oil temperature are same tendency as those of tile forced flowing system and it showed the spinning cylinder system is useful to study the streaming electrification. And, aging of insulation oil increases the electricity of streaming electrification at initial stage of aging.

  • PDF

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle (수소연료전지자동차의 절연성능 평가방법에 관한 고찰)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.810-818
    • /
    • 2011
  • This paper analyzed the suitability about the isolation performance criteria which was based on human impedance and effect of current in IEC 60479-1 on the safety of human being was examined. The method of evaluation by megger and DC voltmeter was analyzed. The differences of isolation performance according to design of high-voltage system were analyzed. The factors which affect the insulation performance were analyzed for HFCV, EV, HEV, etc. through analysis of the isolation performance evaluation method. Finally, design for improved isolation performance was proposed.

The development of On-Line Cathodic Protection Monitoring System (지중 금속구조물의 전기방식 원격감시시스템 개발)

  • 임헌호;정성우;하희천
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.213-218
    • /
    • 2001
  • These days, corrosion condition of a underground objects is measured by the electric potential between the subject and ground. But this method is implemented by means of manual work with analog voltmeter, which is uneconomic and inefficient. So, We developed real-time On-Line cathodic protection monitoring system that is able to detect corrosion potential conditions of metal objects or various steel structures in the ground continuously, display them with the graphic screen, construct a database, and analyze them simultaneously. Since the data of corrosion and corrosion protection of all underground objects is processed automatically, not manually in this system, It is possible to reduce the manipulated error, and perform precise safety management, maintenance and inspection. As as result, this system can not only guarantee long-life operation, reduction of manpower and cost, but prevent large accidents in advance.

  • PDF

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Small Wind Turbine Installed at the University Building Rooftop for Green Energy Utillization (그린에너지 활용을 위한 대학건물 옥상설치형 소형풍력발전)

  • Lee, You Suck;Kim, Jae Yong
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.14-21
    • /
    • 2014
  • As the world supply of fossil fuel sources decreases, the need for efficient energy consevation and develping green energy technologies becomes critical. Because of the high cost of the foundation for large turbines and optional high wind speed (over 12 m/s), it is very difficult to be located at inland city. For the solution above mentioned problem, we have been experimented about that not only using the adaption of wind power system on buildings for improving turbine efficiency, but also applying a wound rotor type induction generator for a small wind turbine.In this research, we try to find out the wind direction and wind speed those were measured every 1 min., during operation period, using the anemometers which consist of horizontally spinning cups on a vertical post. Performance testing for small wind turbine generating system was carried out by using the induction motor and invertor. Finally, we measured the power of 1 kW wind turbine system with the clamp meter and a voltmeter.