• Title/Summary/Keyword: Voltage-current characteristic

Search Result 877, Processing Time 0.027 seconds

Evaluation of Insulation Characteristics of Submarine Cables in Offshore Wind Farm by Excessive Tension (과도한 인장력에 따른 해상풍력단지 해저케이블의 절연 특성 평가)

  • Seung-Won Lee;Jin-Wook Choe;Ik-Su Kwon;Dong-Eun Kim;Hae‑Jong Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.286-291
    • /
    • 2024
  • Research on aged insulation of cables by stress is constantly being considered for reliable and stable power transmission of offshore wind farms. This study aimed to evaluate the insulation characteristic of aged XLPE (cross-linked polyethylene) insulation for application of offshore wind farms. In this study, The XLPE insulation of cable was set as various mechanical strains. The XLPE insulation is exposed to the mechanical stress below yield strain of 5%, 10%, and 20%. Aged samples were tested by using the method of AC BDV (alternative current breakdown voltage), tensile strength, elongation, and SEM (scanning electron microscope) to obtain insulation characteristics. The experimental results show that the dielectric breakdown of the sample with a strain 20% was 50% lower than the unaged sample; thereby, demonstrating that the mechanical strain that occurred in the submarine cables can weaken the insulation characteristics. Therefore, mechanical strain should be monitored when laying and operating submarine cables for offshore wind farms.

ROC Analysis of Simulated Chest Lesions for Computed Radiography and Digital Radiography at Various Tube Voltages (다양한 관전압에 따른 CR과 DR 모의병변 흉부 영상의 ROC 평가)

  • Cho, Hyo-Min;Kim, Hee-Joung;Lee, Chang-Lae;Jung, Ji-Young;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.298-304
    • /
    • 2008
  • Current digital radiographic systems are rapidly growing in clinical applications. The purpose of this study was to evaluate the diagnostic performance of computed radiography (CR) and digital radiography (DR) at different tube voltages in the detection of simulated chest lesions. Patterns of simulated interstitial lung disease, incipient infiltration, and nodules were superimposed over an anthropomorphic chest phantom. A simulated chest phantom radiograph was obtained with CR and DR at different tube voltages (70 kV, 90 kV, and 120 kV). A total of 18,000 observations were analyzed using a receiver operating characteristic (ROC) analysis. The detection of all lesions showed higher $A_z$ values at 70 kV than 120 kV with CR. For the DR, mean $A_z$ values at 70 kV were higher than other tube voltages not all lesions but for micro-nodule interstitial lung disease, linear interstitial lung disease, and incipient infiltration. Based on these results, a clinical study should be performed to judge the use of suitable tube voltage according to the type of detector system and lesions.

  • PDF

Annealed effect on the Optical and Electrical characteristic of a-IGZO thin films transistor.

  • Kim, Jong-U;Choe, Won-Guk;Ju, Byeong-Gwon;Lee, Jeon-Guk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.53.2-53.2
    • /
    • 2010
  • 지금까지 능동 구동 디스플레이의 TFT backplane에 사용하고 있는 채널 물질로는 수소화된 비정질 실리콘(a-Si:H)과 저온 폴리실리콘(low temperature poly-Si)이 대표적이다. 수소화된 비정질 실리콘은 TFT-LCD 제조에 주로 사용되는 물질로 제조 공정이 비교적 간단하고 안정적이며, 생산 비용이 낮고, 소자 간 특성이 균일하여 대면적 디스플레이 제조에 유리하다. 그러나 a-Si:H TFT의 이동도(mobility)가 1 cm2/Vs이하로 낮아 Full HD 이상의 대화면, 고해상도, 고속 동작을 요구하는 UD(ultra definition)급 디스플레이를 개발하는데 있어 한계 상황에 다다르고 있다. 또한 광 누설 전류(photo leakage current)의 발생을 억제하기 위해서 화소의 개구율(aperture ratio)을 감소시켜야하므로 패널의 투과율이 저하되고, 게이트 전극에 지속적으로 바이어스를 인가 시 TFT의 문턱전압(threshold voltage)이 열화되는 문제점을 가지고 있다. 문제점을 극복하기 위한 대안으로 근래 투명 산화물 반도체(transparent oxide semiconductor)가 많은 관심을 얻고 있다. 투명 산화물 반도체는 3 eV 이상의 높은 밴드갭(band-gap)을 가지고 있어 광 흡수도가 낮아 투명하고, 광 누설 전류의 영향이 작아 화소 설계시 유리하다. 최근 다양한 조성의 산화물 반도체들이 TFT 채널 층으로의 적용을 목적으로 활발하게 연구되고 있으며 ZnO, SnO2, In2O3, IGO(indium-gallium oxide), a-ZTO(amorphous zinc-tin-oxide), a-IZO (amorphous indium-zinc oxide), a-IGZO(amorphous indium-galliumzinc oxide) 등이 그 예이다. 이들은 상온 또는 $200^{\circ}C$ 이하의 낮은 온도에서 PLD(pulsed laser deposition)나 스퍼터링(sputtering)과 같은 물리적 기상 증착법(physical vapor deposition)으로 손쉽게 증착이 가능하다. 특히 이중에서도 a-IGZO는 비정질임에도 불구하고 이동도가 $10\;cm2/V{\cdot}s$ 정도로 a-Si:H에 비해 월등히 높은 이동도를 나타낸다. 이와 같이 a-IGZO는 비정질이 가지는 균일한 특성과 양호한 이동도로 인하여 대화면, 고속, 고화질의 평판 디스플레이용 TFT 제작에 적합하고, 뿐만 아니라 공정 온도가 낮은 장점으로 인해 플렉시블 디스플레이(flexible display)의 backplane 소재로서도 연구되고 있다. 본 실험에서는 rf sputtering을 이용하여 증착한 a-IGZO 박막에 대하여 열처리 조건 변화에 따른 a-IGZO 박막들의 광학적, 전기적 특성변화를 살펴보았고, 이와 더불어 a-IGZO 박막을 TFT에 적용하여 소자의 특성을 분석함으로써, 열처리에 따른 Transfer Curve에서의 우리가 요구하는 Threshold Voltage(Vth)의 변화를 관찰하였다.

  • PDF

A Study on Grounding Characteristic Analysis of Large-scaled Apartment Complex Based on PSCAD/EMTDC (PSCAD/EMTDC에 의한 대규모 아파트단지의 접지특성 해석에 관한 연구)

  • Lee, Hu-Dong;Shin, Myeong-Ki;Choi, Sung-Sik;Kang, Min-Kwan;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.650-658
    • /
    • 2017
  • A grounding system in a large-scale apartment complex consists of a TT grounding system when viewed in each building unit, but the characteristics of TN grounding system appears when viewed in the total ground system function. Therefore, this study examined the characteristics of a grounding system in a large-scale apartment complex using design draft, field measurements and PSCAD/EMTDC modeling. This paper proposes an algorithm for fault analysis depending on the grounding system structure in large-scale apartment complexes considering the connection of the underground culvert as well as a design algorithm for each grounding system considering the contact voltage and step voltage. The simulation results based on the proposed modeling and algorithm confirmed that it is useful for analyzing the characteristics of a grounding system in a large-scale apartment complex.

The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method (Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가)

  • Lee, Y.K.;Yon, M.S.;KIM, D.H.;Chun, S.L.;Jung, B.D.;Gang, Sang-Sik;Park, J.G.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2009
  • Mercury Iodide as good sensitivity at radiation and has an easy peculiarity that operates at low voltage for other photoconductors(a-Se, a-Si, Ge, etc) Based on this characteristic, we studied about an efficiency of the digital x-ray detector in acccordance with the thickness of photoconductor. To solve the problem that is difficult to make a large area film using PVD(Physical Vapor Deposition)method, we used a PIB(Particle In Binder)method. To make a binder paste, we used a PVB(Polyvinylbutyral) as a binder and a DGME(Diethylene Glycol Monobutyl Ether), DGMEA(Diethylene Glycol Monobutyl Ether Acetate) as a solvent. Using this binder paste, we made a polycrystal mercury iodide film that has an each thickness. To evaluate the electrical properties of this films, we measured a darkcurrent, sensitivity and SNR(Signal to Noise Ratio). Mercury iodide film of the 200um thickness has good electrical properties as a result of the measurement. From this result there is a good chance that replace the existing a-Se(Amnorphous seleinum; a-se) with the mercury iodide.

  • PDF

Material Characteristic of POFA Concrete and Its Application to Corrosion Resistance Evaluation (POFA 콘크리트의 재료특성 및 부식 저항성 평가로의 적용)

  • Lee, Chang-Hong;Song, Ha-Won;Ann, Ki-Yong;Ismail, Mohamed Abdel
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.565-572
    • /
    • 2009
  • In this study, corrosion resistance of palm oil fuel ash (POFA) concrete as a blended concrete is evaluated by using electrochemical technique. The POFA is an industrial byproduct obtained from fuel ash after extracting palm oil from palm-tree. In order to obtain basic material characteristics of the POFA concrete, tests on compressive strength, slump, weight loss, bleeding and expansion ratio were carried out the early-aged POFA concrete. On the other hand, durability characteristics, both chloride penetration and carbonation depth test, were also conducted. Finally, corrosion resistance were evaluated by applying electro-chemical artificial crack healing technique, and the tests on the impressed voltage characteristic, galvanic current and linear polarization resistance. From the experimental results, it was found that long-term strength, bleeding, lower slump ratio, expansion ratio, chloride penetration, carbonation and corrosion resistance were improved by using the POFA due to activated pozzolanic reaction. It can be also mentioned that POFA concrete has a potential to be used as a cementitious binder for green-recycling resources.

A Study on the Characteristic Analysis of Blue OLED for the Luminous Traffic Safety Mark (발광형 교통안전표지용 청색 OLED의 특성분석에 관한 연구)

  • Kang, Myung-Goo;Kim, Jung-Yeoun;Oh, Hwan-Sool
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.2
    • /
    • pp.138-145
    • /
    • 2007
  • Luminous traffic safety mark is restricted to use only the place that has a thick fog, many night traffic accidents, limited field of view due to structure of road. Recently, LEDs are used for luminous traffic safety mark, but we propose an organic LED for a novel luminous traffic safety mark in the near future. The device structure was $ITO/2-TNATA(500{\AA})/{\alpha}-NPD(200{\AA})/DPVBi(300{\AA})/BCP(10{\AA})/Alq_3(200{\AA})/LiF(10{\AA})/Al:Li(1000{\AA})$. The characteristics of the device are most efficient on occasion of using $N_2$ gas plasma treatment. Current density is $240.71mA/cm^2$ luminance $10,550cd/m^2$, and current efficiency 3.53cd/A at an applied voltage of 10V. The maximum EL wavelength of the fabricated blue organic light-emitting device is 456nm. CIE color coordinates are x=0.1449 and y=0.1633, which is similar to NTSC deep-blue color with CIE color coordinates of x=0.14 and y=0.08.

  • PDF

A study on electrical response property of photoconductor film for x-ray imaging sensor (X선 영상센서 적용을 위한 광도전체 필름의 전기적 응답특성 연구)

  • Kang, Sang-Sik;Kim, Chan-Wook;Lee, Mi-Hyun;Lee, Kwang-Ok;Moon, Yong-Soo;An, Sung-A;No, Ci-Chul;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.29-33
    • /
    • 2009
  • Recently, the compound materials(a-Se, $HgI_2$, PbO, CdTe, $PbI_2$, etc.) that are used in flat panel x-ray imager have been studied for digital x-ray imaging. In this paper, the signal detection properties of $HgI_2$ and a-Se conversion layer, are compared. The thick $HgI_2$ film is fabricated by special particle-in-binder method and the conventional vacuum thermal evaporation is used for a deposition of a-Se film. And an electrical characteristic measurements were investigated about leakage current, signal response property and x-ray sensitivity. From the experimental results show that the $HgI_2$ film has a low operation voltage and high signal generation than that of a-Se.

  • PDF

Analysis of Positive Bias Temperature Instability Characteristic for Nano-scale NMOSFETs with La-incorporated High-k/metal Gate Stacks (La이 혼입된 고유전체/메탈 게이트가 적용된 나노 스케일 NMOSFET에서의 PBTI 신뢰성의 특성 분석)

  • Kwon, Hyuk-Min;Han, In-Shik;Park, Sang-Uk;Bok, Jung-Deuk;Jung, Yi-Jung;Kwak, Ho-Young;Kwon, Sung-Kyu;Jang, Jae-Hyung;Go, Sung-Yong;Lee, Weon-Mook;Lee, Hi-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.182-187
    • /
    • 2011
  • In this paper, PBTI characteristics of NMOSFETs with La incorporated HfSiON and HfON are compared in detail. The charge trapping model shows that threshold voltage shift (${\Delta}V_{\mathrm{T}}$) of NMOSFETs with HfLaON is greater than that of HfLaSiON. PBTI lifetime of HfLaSiON is also greater than that of HfLaON by about 2~3 orders of magnitude. Therefore, high charge trapping rate of HfLaON can be explained by higher trap density than HfLaSiON. The different de-trapping behavior under recovery stress can be explained by the stable energy for U-trap model, which is related to trap energy level at zero electric field in high-k dielectric. The trap energy level of two devices at zero electric field, which is extracted using Frenkel-poole emission model, is 1,658 eV for HfLaSiON and 1,730 eV for HfLaON, respectively. Moreover, the optical phonon energy of HfLaON extracted from the thermally activated gate current is greater than that of HfLaSiON.

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.