• 제목/요약/키워드: Voltage-current characteristic

검색결과 877건 처리시간 0.029초

Electrical Behaviors of ZnO Elements under Combined Direct and Alternating Voltages

  • Yang, Soon-Man;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.111-117
    • /
    • 2009
  • This paper presents the characteristics of leakage currents flowing through zinc oxide (ZnO) surge arrester elements under the combined direct-current (DC) and 60 Hz alternating-current (AC) voltages. The current-voltage characteristic curves (I-V curves) of the commercial ZnO surge arrester elements were obtained as a function of the voltage ratio a. At constant peak value of the combined DC and AC voltage, the resistive leakage current of the ZnO blocks was significantly increased as the voltage ratio $\alpha$ increased. The I-V curves under the combined DC and AC voltages were placed between the pure DC and AC characteristics, and the cross-over phenomenon in both the I-V curves and R-V curves was observed at the low current region. The ZnO power dissipation for DC voltages was less than that for AC voltage in the pre-breakdown region and reversed at higher voltages.

Hierarchical Voltage Control of a Wind Power Plant Using the Adaptive IQ-V Characteristic of a Doubly-Fed Induction Generator

  • Kim, Jinho;Park, Geon;Seok, Jul-Ki;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.504-510
    • /
    • 2015
  • Because wind generators (WGs) in a wind power plant (WPP) produce different active powers due to wake effects, the reactive power capability of each WG is different. This paper proposes a hierarchical voltage control scheme for a WPP that uses a WPP controller and WG controller. In the proposed scheme, the WPP controller determines a voltage error signal by using a PI controller and sends it to a doubly-fed induction generator (DFIG). Based on the reactive current-voltage ($I_Q-V$) characteristic of a DFIG, the DFIG injects an appropriate reactive power corresponding to the voltage error signal. To enhance the voltage recovery capability, the gains of the $I_Q-V$ characteristic of a DFIG are modified depending on its reactive current capability so that a DFIG with greater reactive current capability may inject more reactive power. The proposed scheme enables the WPP to recover the voltage at the point of common coupling (PCC) to the nominal value within a short time after a disturbance by using the adaptive $I_Q-V$ characteristics of a DFIG. The performance of the proposed scheme was investigated for a 100 MW WPP consisting of 20 units of 5 MW DFIGs for small and larger disturbances. The results show the proposed scheme successfully recovers the PCC voltage within a short time after a disturbance.

배전급 피뢰기(18kV, 5kA)용 산화아연바리스타의 성능향상에 관한 연구 (A Study on the Improvement of ZnO Varistor for Distribution Class Surge Arrester(18kV, 5kA))

  • 유덕선;윤한수;김석수;최연규;장성도
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.744-746
    • /
    • 2003
  • A ZnO varistor with reference voltage 250V/mm was fabricated through the control of particle size in slurry and the variation of sintering conditions. It was found that to measure the flatness of the V-I characteristic curve in the small-current region and the flatness of the V-I characteristic curve in a large-current region was improved nonlinearity of the fabricated ZnO varistor. According to the IEC 60099-4 was measured the accelerated aging test and high current test of the distribution class surge varistor which is excellent in respect to the property of ZnO varistor.

  • PDF

에틸렌프로필렌 고무의 전압에 의한 누설전류 특성에 관한 연구 (A Study on Properties Leakage Current due to Voltage of Ethylene Propylene Rubber)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제26권12호
    • /
    • pp.872-877
    • /
    • 2013
  • In this study, the leakage current - voltage characteristic and leakage current - time characteristic for the undegradated Ethylene Propylene Rubber and the Ethylene Propylene Rubber which is degradated by water tree for 200 hours have been measured on the temperature range of $50{\sim}80^{\circ}C$ and applied DC voltage range of 200 V~800 V for 90 minutes. The results of this study are listed below. In case the temperature is $50^{\circ}C$, it founds that the leakage current have shown a increase in proportion to the applied voltage as 2 pA in 200 V, 6 pA in 400 V, 10 pA in 600 V and 15 pA in 800 V. It founds that the leakage current increased with the rise of temperature. It founds that the leakage current was consistent as time goes by, the leakage current of the sample degradated by water tree for 200 hours has increased more than undegradated sample.

플라즈마중합 PPMMA의 전기전도 기구에 관한 연구 (The study on electrical conduction mechanism of plasma-polymerized methyl methacrylate (PPMMA))

  • 박재윤;박광현;한상욱;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.283-285
    • /
    • 1987
  • Transient conduction current (I - t characteristics) were measured in thin PPMMA (plasma-polymerized methyl methacrylate) films over the temperature range $60^{\circ}C-140^{\circ}C$ and the applied voltage range 3V - 30V. The current, which increased with temperature rise at constant applied voltage, showed less absorption current (current decay with time) at higher temperature region compared with those at lower temperature region. And the current, which increased with applied voltage rise at the constant temperature, showed less absorption current at higher voltage compared with those at lower voltage. The electric field current density characteristic curves were abtained from the conduction current values were after applying voltage for 30 minutes. And transient conduction currents were analyzed with high field conduction theories.

  • PDF

비정질 실리콘 박막 트랜지스터 히스테리시스 특성 (Hysteresis Characteristics of a-Si:H TFT)

  • 이우선;정용호;김남오;김병인;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 춘계학술대회 논문집
    • /
    • pp.43-46
    • /
    • 1995
  • We fabricate a bottom gate a-Si:H TFT on N-Type <100> Si wafer. According to the variation of gate and drain voltage, the hysteresis characteristic curves were measured experimentally. Also, we showed that the model predict the hysteresis characteristic successfully. Drain current on the hysteresis characteristic currie showed an exponential variation. Hysteresis area of TFT increased with the drain voltage increase and decreases with the drain voltage decrease.

  • PDF

비정질 실리코 박막 트랜지스터 히스테리시스 특성의 수학적인 모델 (Mathematical Modeling of Hysteresis Characteristics of a-Si:H TFT)

  • Lee, Woo-Sun;Kim, Byung-In
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1135-1143
    • /
    • 1994
  • We fabricate a bottom gate a-Si:H TFT on N-Type <100> Si wafer. According to the Variation of gate and drain voltage, the hysteresis characteristic curves were measured experimentally. Also, we proposed model equation and showed that the model predict the hysteresis characteristic successfully. Drain current on the hysteresis characteristic curve showed an exponential variation. Hysteresis area of TFT increased with the drain voltage increase and decreases with the drain voltage decrease.

  • PDF

저전압 3상 다이오드 정류회로의 특성 실험 (Characteristic Experimental of Low Voltage Three phase Diode Rectifier Circuit)

  • 서기영;김영문;문상필;김주용;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.89-92
    • /
    • 2001
  • In conventional three-phase rectifiers, it was necessary to use a transformer to obtain low output voltage. In this paper, we propose a characteristic experimental of three-phase diode rectifiers circuit that achieves low voltage by using a very simple circuit configuration that does not have a transformer and does not need any complex control. We also describe the operation principle of the proposed circuit, and der?ive a theoretical formula for its current waveform. On the basis these theoretical values with experimentally obtained input output current characteristics, current amplification factor, and output voltage characteristics, allowed us to confirm the soundness of our theoretical analyses.

  • PDF

MicroTec을 이용한 태양전지 전류-전압 특성곡선 분석 (Analysis of Current-voltage Characteristic Curve for the Solar Cell using MicroTec Tool)

  • 정학기;한지형
    • 한국정보통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1045-1050
    • /
    • 2009
  • 본 연구에서는 MicroTec을 이용하여 태양전지의 전류-전압 특성곡선을 분석하였다. 전류-전압 특성곡선은 태양전지의 효율을 나타낸다. 전극이 직접 접촉하는 부분에 고농도 도핑을 하고 전극이 없는 부분에 저농도 도핑으로 전면을 처리한다. 도핑 농도를 $10^{14}cm^{-3}$에서 $10^{17}cm^{-3}$까지 변화시켜 도핑 농도에 따른 전류전압특성을 조사하였다. 또한 태양전지의 최대효율을 얻을 수 있는 도핑 농도를 결정하여 이의 전류-전압특성곡선을 비교 분석 하고자한다.

뇌격전류 측정의 정확도에 영향을 미치는 요인 (Factors Affected the Accuracy of Lightning Current Measuring System)

  • 이복희;장근철;강성만;엄주홍;정길조;심응보;우정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF