• Title/Summary/Keyword: Voltage phase

Search Result 4,303, Processing Time 0.037 seconds

$TiO_2$ Thin Film Patterning on Modified Silicon Surfaces by MOCVD and Microcontact Printing Method

  • 강병창;이종현;정덕영;이순보;부진효
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.77-77
    • /
    • 2000
  • Titanium oxide (TiO2) thin films have valuable properties such as a high refractive index, excellent transmittance in the visible and near-IR frequency, and high chemical stability. Therefore it is extensively used in anti-reflection coating, sensor, and photocatalysis as electrical and optical applications. Specially, TiO2 have a high dielectric constant of 180 along the c axis and 90 along the a axis, so it is highlighted in fabricating dielectric capacitors in micro electronic devices. A variety of methods have been used to produce patterned self-assembled monolayers (SAMs), including microcontact printing ($\mu$CP), UV-photolithotgraphy, e-beam lithography, scanned-probe based micro-machining, and atom-lithography. Above all, thin film fabrication on $\mu$CP modified surface is a potentially low-cost, high-throughput method, because it does not require expensive photolithographic equipment, and it produce micrometer scale patterns in thin film materials. The patterned SAMs were used as thin resists, to transfer patterns onto thin films either by chemical etching or by selective deposition. In this study, we deposited TiO2 thin films on Si (1000 substrateds using titanium (IV) isopropoxide ([Ti(O(C3H7)4)] ; TIP as a single molecular precursor at deposition temperature in the range of 300-$700^{\circ}C$ without any carrier and bubbler gas. Crack-free, highly oriented TiO2 polycrystalline thin films with anatase phase and stoichimetric ratio of Ti and O were successfully deposited on Si(100) at temperature as low as 50$0^{\circ}C$. XRD and TED data showed that below 50$0^{\circ}C$, the TiO2 thin films were dominantly grown on Si(100) surfaces in the [211] direction, whereas with increasing the deposition temperature to $700^{\circ}C$, the main films growth direction was changed to be [200]. Two distinct growth behaviors were observed from the Arhenius plots. In addition to deposition of THe TiO2 thin films on Si(100) substrates, patterning of TiO2 thin films was also performed at grown temperature in the range of 300-50$0^{\circ}C$ by MOCVD onto the Si(100) substrates of which surface was modified by organic thin film template. The organic thin film of SAm is obtained by the $\mu$CP method. Alpha-step profile and optical microscope images showed that the boundaries between SAMs areas and selectively deposited TiO2 thin film areas are very definite and sharp. Capacitance - Voltage measurements made on TiO2 films gave a dielectric constant of 29, suggesting a possibility of electronic material applications.

  • PDF

Design of pHEMT channel structure for single-pole-double-throw MMIC switches (SPDT 단일고주파집적회로 스위치용 pHEMT 채널구조 설계)

  • Mun Jae Kyoung;Lim Jong Won;Jang Woo Jin;Ji, Hong Gu;Ahn Ho Kyun;Kim Hae Cheon;Park Chong Ook
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.207-214
    • /
    • 2005
  • This paper presents a channel structure for promising high performance pseudomorphic high electron mobility transistor(pHEMT) switching device for design and fabricating of microwave control circuits, such as switches, phase shifters, attenuators, limiters, for application in personal mobile communication systems. Using the designed epitaxial channel layer structure and ETRI's $0.5\mu$m pHEMT switch process, single pole double throw (SPDT) Tx/Rx monolithic microwave integrated circuit (MMIC) switch was fabricated for 2.4 GHz and 5 GHz band wireless local area network (WLAN) systems. The SPDT switch exhibits a low insertion loss of 0.849 dB, high isolation of 32.638 dB, return loss of 11.006 dB, power transfer capability of 25dBm, and 3rd order intercept point of 42dBm at frequency of 5.8GHz and control voltage of 0/-3V These performances are enough for an application to 5 GHz band WLAN systems.

Studies on the Determination Method of Hydrogen Peroxide in Foods (식품 중 과산화수소의 분석법에 관한 연구)

  • Lee, Tal-Soo;Lee, Young-Ja;Park, Jae-Seok;Kwon, Yong-Kwan;Hwang, Jung-Yeon;Lee, Ju-Yeun;Lee, Chul-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.998-1001
    • /
    • 2002
  • Micro-LC method for the quantitative determination of hydrogen peroxide in foods has been established. This method was carried out on cation-exchange resin gel column using distilled water as mobile phase with 50 mM sodium sulfate as electrolyte. The detection was performed with an electrochemical detector (ECD) at 0.6 voltage. Under this analytical condition, the recovery rates of hydrogen peroxide in tomato and lemon were 98.3 and 97.4%, respectively. Among 28 food types, hydrogen peroxide concentrations were 0.6, 0.5, 1.9, 0.9, 0.5, 0.6, 0.9, 0.8, and 0.4 ppm in banana, peach, orange, strawberry, pepper, onion, cucumber, burdock, and egg plant, respectively, Whereas none was detected in remaing 19 samples.

Structural and Electrical Properties of K(Ta,Nb)O3 Ceramics with Variation of Ag Contents for Electrocaloric Devices (전기열량소자용 Ag 첨가량에 따른 K(Ta,Nb)O3 세라믹스의 구조적·전기적 특성)

  • Lee, Min-Sung;Park, Byeong-Jun;Lim, Jeong-Eun;Lee, Sam-Haeng;Lee, Myung-Gyu;Park, Joo-Seok;Lee, Sung-Gap
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.442-448
    • /
    • 2021
  • In this work, the (K1-xAgx)(Ta0.8Nb0.2)O3 (x=0.1-0.4) ceramics were fabricated using mixed-oxide method, and their structural and electrical properties were measured. All specimens represented a pseudo cubic structure with the lattice constant of 0.3989 nm. When 0.4 mol of Ag was added, second phases induced from metallic Ag and K2(Ta,Nb)6O16 phase were observed. Dielectric constant and dielectric loss of K(Ta0.8Nb0.2)O3 specimen doped with 0.3 mol of Ag were 2,737 and 0.446, respectively. The curie temperature was about -5℃, which does not change with Ag addition. The remanent polarization began to decrease sharply around 12~15℃, and the temperature at which the remanent polarization began to decrease as the applied voltage increased shifted to the high temperature side. The electrocaloric effect (ΔT) and electrocaloric efficiency (ΔT/ΔE) of the (K0.7Ag0.3)(Ta0.8Nb0.2)O3 ceramics were 0.01024℃ and 0.01825 KmV-1, respectively.

Mechanism of Catecholamine Secretion Evoked by Lithium from the Isolated Perfused Rat Adrenal Gland (흰쥐 적출관류부신에서 리튬에 의한 카테콜아민 분비작용의 기전)

  • Lim, Dong-Yoon;Kim, Cheol;Oh, Hyeong-Geun
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.3
    • /
    • pp.357-371
    • /
    • 1996
  • Lithium (Li) is known to be used not only during acute manic psychosis but also acute depressive phase in manic-depression. In the present study, it was attempted to investigate the effect of lithium on catecholamine (CA) secretion from the isolated perfused rat adrenal gland and to clarify the mechanism of its action. Replacement of $Na^+$ (118.4 mM) by lithium in the normal Krebs-bicarbonate solution used to perfuse the gland produced gradually an increased response in the spontaneous catecholamine release, which was peaked at $30{\sim}60$ min after its perfusion. Li-Krebs solution was perfused into an adrenal vein for 2 hours in every experiments. Li-Krebs-evoked CA secretory responses were depressed significantly under loading with $Ca^{++}-free$ medium. This CA secretion evoked by lithium loading was also reduced markedly by the pretreatment with nicardipine ($10^{-6}$ M), TMB-8 ($10^{-5}$ M) and chlorisondamine ($10^{-6}$ M) for 20 min, respectively, while was not affected by preloading with a pirenzepine ($2{\times}10^{-6}$ M)-containing Krebs. $Na^+$ pump inhibition by pretreatment with ouabain ($10^{-4}$ M) for 20 min did make the marked depression in Li-evoked CA secretory responses. Moreover, Li-evoked CA release was also diminished markedly by preloading with tetrodotoxin ($5{\times}10^{-7}$ M)-contaming Krebs for 20 min. All these experimental results taken together suggest that lithium enhances CA secretion in a $Ca^{++}$-dependent fashion by its accumulation in the adrenomedullary chromaffin cells of the rat, and that this secretory effect may be meidated by a dual mechanism: (i) chromaffin cell depolarization and subsequent opening of voltage-sensitive $Ca^{++}$ channels and (ii) activation of a $[Li]_i-[Ca]_0$ counter-transport system.

  • PDF

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

Characteristics of Sn-doped β-Ga2O3 single crystals grown by EFG method (EFG 법으로 성장한 β-Ga2O3 단결정의 Sn 도핑 특성 연구)

  • Tae-Wan Je;Su-Bin Park;Hui-Yeon Jang;Su-Min Choi;Mi-Seon Park;Yeon-Suk Jang;Won-Jae Lee;Yun-Gon Moon;Jin-Ki Kang;Yun-Ji Shin;Si-Yong Bae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.2
    • /
    • pp.83-90
    • /
    • 2023
  • The β-Ga2O3 has the most thermodynamically stable phase, a wide band gap of 4.8~4.9 eV and a high dielectric breakdown voltage of 8MV/cm. Due to such excellent electrical characteristics, this material as a power device material has been attracted much attention. Furthermore, the β-Ga2O3 has easy liquid phase growth method unlike materials such as SiC and GaN. However, since the grown pure β-Ga2O3 single crystal requires the intentionally controlled doping due to a low conductivity to be applied to a power device, the research on doping in β-Ga2O3 single crystal is definitely important. In this study, various source powders of un-doped, Sn 0.05 mol%, Sn 0.1 mol%, Sn 1.5 mol%, Sn 2 mol%, Sn 3 mol%-doped Ga2O3 were prepared by adding different mole ratios of SnO2 powder to Ga2O3 powder, and β-Ga2O3 single crystals were grown by using an edge-defined Film-fed Growth (EFG) method. The crystal direction, crystal quality, optical, and electrical properties of the grown β-Ga2O3 single crystal were analyzed according to the Sn dopant content, and the property variation of β-Ga2O3 single crystal according to the Sn doping were extensively investigated.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

FES Exercise Program for Independent Paraplegic Walking (하반신 마비환자의 FES 독립보행을 위한 근육 강화 프로그램)

  • Khang, Seon-Hwa;Khang, Gon;Choi, Hyun-Joo;Kim, Jong-Moon;Chong, Soon-Yeol;Chung, Jin-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.69-80
    • /
    • 1998
  • This research was designed to investigate how the exercise program affects paraplegic standing and walking employing functional electrical stimulation(FES). Emphasis was also given to fatigue of major lower extremity muscles induced by different types of electrical stimulation. We applied continuous and intermittent rectangular pulse trains to quadriceps of 10 normal subjects and 4 complete paraplegic patients. The frequencies were 20Hz and 80Hz, and the knee angle was fixed at 90$^{\circ}$and 150$^{\circ}$to investigate how muscle fatigue is related to muscle length. The knee extensor torque was measured and monitored. We have been training quadriceps and gastrocnemius of a male paraplegic patient by means of electrical stimulation for the past two year. FES standing was initiated when the knee extensors became strong enough to support the body weight, and then the patient started FES walking utilizing parallel bars and a walker. We used an 8-channel constant-voltage stimulator and surface electrodes. The experimental results indicated that paralyzed muscles fatigued rapidly around the optimal length contrary to normal muscles and confirmed that low frequency and intermittent stimulation delayed fatigue. Our exercise program increased muscle force by approximately 10 folds and decreased the fatigue index to half of the initial value. In addition, the exercise enabled the patient to voluntarily lift each leg up to 10cm, which was of great help to the swing phase of FES walking. Both muscle force and resistance to fatigue were significantly enhanced right after the exercise was applied every day instead of 6 days a week. Up to date, the patient can walk for more than two and half minutes at 10m/min while controlling the on/off time of the stimulator by pushing the toggle switch attached to the walker handle.

  • PDF