• 제목/요약/키워드: Voltage losses

검색결과 657건 처리시간 0.023초

무손실 스너버적용 고주파 소프트 스위칭 Forward 컨버터 (High Frequency Soft Switching Forward DC/DC Converter Using Non-dissipative Snubber)

  • 최해영;김은수;변영복;김철수;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.614-617
    • /
    • 1999
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.

  • PDF

ESGA를 이용한 불평형 배전계통의 커패시터 설치에 관한 연구 (A Study on Capacitor Placement Using ESGA Hybrid Approach in Unbalanced Distribution Systems)

  • 김규호;이유정;이상봉;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.316-324
    • /
    • 2003
  • This paper applied Elite-based Simplex-GA hybrid approach combined with Muptipop-GA (ESGA) to determining the location, size and number of capacitors to improve voltage profile and minimize power losses in unbalanced distribution systems. One of the main obstacles in applying GA to complex problems has been the high computational cost due to their slow convergence rate. To alleviate this difficulty, ESGA approach was developed that combines Elite-based Simplex-GA hybrid approach with Muptipop-GA. The objective function formulated consists of two terms: cost for energy losses and cost related to capacitor purchase and capacitor installation. The cost function associated with capacitor placement is considered as a step function due to banks of standard discrete capacities. Its efficiency was proved through the application in IEEE 13 bus and 34 bus test systems and was compared with several methods using GA.

도통손실 저감을 위한 새로운 역률 보상 AC/DC 컨버터 (A Novel PFC AC/DC Converter for Reducing Conduction Losses)

  • 강필순;김광태;홍순일;김철우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.273-278
    • /
    • 1999
  • This paper presents a novel Power Factor Corrected(PFC) single-stage AC/DC Half-Bridge converter, which features discontinuous conduction mode(DCM) and soft-switching. The reduced conduction losses are achieved by the employment of a novel power factor correction circuitry, instead of the conventional configuration composed of a front-end rectifier followed by a boost converter. To identify the validity of the proposed converter, simulated results of 500[W] converter with 100[V] input voltage and 50[V] output voltage are presented.

  • PDF

하프브릿지형 DC-DC 컨버터의 효율특성 비교에 관한 연구 (A study on comparison of efficiency characteristics for half bridge type DC-DC converters)

  • 이광택;안태영;김성철;유병우;봉상철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.356-359
    • /
    • 2006
  • This paper presented the power losses comparison results with the Active clamp Forward, the Asymmetrical half bridge and the Two transistor forward converters. To estimate for conduction losses in the converters, the steady state analysis regard to parasitic resistance and current effective values for main parts of converters was derived. In addition, the theoretical efficiency for the converters with input voltage 400V, output voltage 12V and maximum power 480W was discussed.

  • PDF

RPWM 기법을 이용한 능동클램프 ZVS 플라이백 컨버터 전도노이즈저감 (Conducted Noise Reduction in Active clamp ZVS flyback converter using Random Pulse Width Modulation)

  • 김영규;최태영;원충연;김재문;김규식;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.498-501
    • /
    • 2002
  • In the conventional PWM converter, high-frequency switching techniques was used for high-density of energy, but occurred a lot of problems such as switching losses, switching voltage/current stresses, EMI(Electromgnetic Interference) and so on. To overcome these problems, various soft switching techniques have been presented. However these techniques are focused on reducing switching losses and voltage/current stresses . The simulation and experimental results are shown that the active clamp ZVS flyback converter with the proposed RPWM(Random Pulse Width Modulation) technique reduces the conducted noise.

  • PDF

A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

Advanced Cascade Multilevel Converter with Reduction in Number of Components

  • Ajami, Ali;Oskuee, Mohammad Reza Jannati;Mokhberdoran, Ataollah;Khosroshahi, Mahdi Toupchi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.127-135
    • /
    • 2014
  • In this paper a novel converter structure based on cascade converter family is presented. The suggested multilevel advanced cascade converter has benefits such as reduction in number of switches and power losses. Comparison depict that proposed topology has the least number of IGBTs among all multilevel cascade type converters which have been introduced recently. This characteristic causes low cost and small installation area for suggested converter. The number of on state switches in current path is less than conventional topologies and so the output voltage drop and power losses are decreased. Symmetric and asymmetric modes are analyzed and compared with conventional multilevel cascade converter. Simulation and experimental results are presented to illustrate validity, good performance and effectiveness of the proposed configuration. The suggested converter can be applied in medium/high voltage and PV applications.

수정된 민감도 기법을 이용한 선형계획법 기반의 무효전력 최적배분 (Linear Programming based Optimal Reactive Power Dispatch using Modified Sensitivity Method)

  • 김태권;김병섭;김민수;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.190-193
    • /
    • 2001
  • This paper presents a linear programming based Optimal Reactive Power Dispatch (ORPD) problem using modified sensitivity method. The proposed model minimizes the real power losses and improves the voltage profiles in the system with consideration of voltage and reactive power constraints. The method employs modified sensitivity relationships of power systems to establish both the objective function for minimizing the system losses and the system performance sensitivities relating dependent and control variables. The proposed algorithm has been evaluated with the IEEE 6-bus and IEEE 30-bus systems.

  • PDF

A High-Efficiency Bidirectional AC/DC Topology for V2G Applications

  • Su, Mei;Li, Hua;Sun, Yao;Xiong, Wenjing
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.899-907
    • /
    • 2014
  • This paper proposes a single-phase bidirectional AC/DC converter topology applied in V2G systems, which consists of an inverter and a bidirectional non-inverting buck-boost converter. This topology can operate in four modes: buck charging, boost charging, buck discharging and boost discharging with high input current quality and unity input power factor. The inverter switches at line frequency, which is different from conventional voltage source inverters. A bidirectional buck-boost converter is utilized to adapt to a wider charging voltage range. The modulation and control strategy is introduced in detail, and the switching patterns are optimized to reduce the current ripple. In addition, the semiconductor losses are analyzed. Simulation and experimental results demonstrate the validity and effectiveness of the proposed topology.

영전압, 영전류 스위칭 1단 방식 역률 보상 AC/DC 컨버터 (ZVZCS Single-Stage Power Factor Corrected Converter)

  • 강필순;박성준;권순재;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1348-1350
    • /
    • 2000
  • Zero-voltage and zero-current switched single-stage approach with high power factor is presented to reduce the switching losses and to achieve sinusoidal, unity power factor input currents. This single-stage approach, which combines a boost converter used as PFC with a half-bridge converter used as do to do conversion into one power stage, has a simple structure and low cost. At the same time, since the switches of the proposed converter are designed to be turned on at zero-voltage and off at zero-current, the switching losses could be reduced considerably. Detailed analysis and experimental results are presented on the proposed converter, which is operated at constant switching frequency and in discontinuous conduction mode.

  • PDF