• Title/Summary/Keyword: Voltage compensation

Search Result 1,122, Processing Time 0.023 seconds

A Study on the Quantatitive Evaluation of Voltage Stability Improvement Effect By the T/L-Loss System Identification Method (송전손실 상태식별법을 이용한 전압안정성 개선효과의 정량적 평가에 관한 연구)

  • Choi, Jong-Key;Lee, Bong-Yong;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.45-47
    • /
    • 1994
  • The simulation of reactive power compensation in 5-bus and 25-bus system was conducted using transmission-line loss system identification method. Sensitivities of maximum load-power with respect to reactive power compensation was identified by the simulation. With sufficient reactive power compensation at the first voltage-collapsing load-bus, the first voltage collapse could be prevented until the next voltage-collapsing load-bus lost its voltage stability. And the total compensated reactive power at the first voltage-collapsing bus means reactive power margin of voltage collapse or distance to voltage collapse. This quantity can be useful for determining the size of compensating devices or the site to compensate.

  • PDF

Modeling and Control Design of Dynamic Voltage Restorer in Microgrids Based on a Novel Composite Controller

  • Huang, Yonghong;Xu, Junjun;Sun, Yukun;Huang, Yuxiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1645-1655
    • /
    • 2016
  • A Dynamic Voltage Restorer (DVR) model is proposed to eliminate the short-term voltage disturbances that occur in the grid-connected mode, the switching between grid-connected mode and the stand-alone mode of a Microgrid. The proposed DVR structure is based on a conventional cascaded H-bridge multilevel inverter (MLI) topology; a novel composite control strategy is presented, which could ensure the compensation ability of voltage sag by the DVR. Moreover, the compensation to specified order of harmonic is added to implement effects that zero-steady error compensation to harmonic voltage in specified order of the presented control strategy; utilizing wind turbines-batteries units as DC energy storage components in the Microgrid, the operation cost of the DVR is reduced. When the Microgrid operates under stand-alone mode, the DVR can operate on microsource mode, which could ease the power supply from the main grid (distribution network) and consequently be favorable for energy saving and emission reduction. Simulation results validate the robustness and effective of the proposed DVR system.

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.

A Study on the Analysis and Control of Voltage Stability (전압안정성 분석 및 제어에 관한 연구)

  • 장수형;김규호;유석구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.869-876
    • /
    • 1994
  • This paper presents an efficient method to calculate voltage collapse point and to avoid voltage instability. To evaluate voltage stability in power systems, it is necessary to get critical loading points. For this purpose, this paper uses linear programming to calculate efficiently voltage collapse point. Also, if index value becomes larger than given threshold value, voltage stability is improved by compensation of reactive power at selected bus. This algorithm is verified by simulation on the IEEE 14-bus sample system.

  • PDF

A Study on the Application of the DVR System using EMTDC Simulation (EMTDC 시뮬레이션을 이용한 DVR 시스템 적용에 관한 연구)

  • Choy, Y.D.;Kwak, N.H.;Jeon, Y.S.;Jeon, D.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.69-71
    • /
    • 2008
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and become more sensitive to the voltage disturbance. The DVR(Dynamic Voltage Restorer) is one of the Custom Power Device that can compensate the voltage. DVR operates as a series connected compensator whose output voltage can be controlled system voltage. And the magnitude of compensation voltage is limited by the characteristics of system and load. Compensation capability of DVR was simulated by EMTDC under several condition. This paper analyzed effect of DVR's compensation at power quality test center which has SSFG(Sag, swell, and Flicker Generator, CPDs(SSTS, DVR, DSTATCOM), and loads.

  • PDF

Analysis and Compensation of PCC Voltage Variations caused by Wind Turbine Power Fluctuations

  • Im, Ji-Hoon;Song, Seung-Ho;Kang, San
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.854-860
    • /
    • 2013
  • The voltage variation problem at the point of common coupling (PCC) in a grid-connected wind turbine is investigated. The voltage variation problem is one of the most frequent power quality issues for the grid connection of large amounts of input power in a weak grid. Through the simplified modeling of the wind turbine and power network, the magnitude of PCC voltage variation is calculated by using the equivalent circuit parameters and output power of the wind turbine. The required amount of reactive power that can compensate the voltage variation is also presented analytically by using the vector diagram method. The proposed calculation and compensation method of the PCC voltage variation is verified by computer simulations and experiments.

Determining the Compensation Voltages for Dynamic Voltage Restorers by use of PQR Instantaneous Power Theory (PQR 순시전력이론에 의한 동적전압보상기의 보상전압 결정)

  • 김효성;이상준;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.442-449
    • /
    • 2003
  • This paper discusses how to generate the reference compensation voltages in Dynamic Voltage Restorers (DVR) by use of PQR instantaneous power theory. Sensed three-phase terminal voltages are transformed to PQR coordinates without time delay. Since the reference voltage in PQR coordinates is a single dc value, the voltage controller for DVRs is simple and easy to design. Proposed control method can be implemented by feedforward controllers or by feedback controllers. This paper verified the theory by a feedforward controller of a DVR with simulation and experiment.

Modified Low-Votlage CMOS Bandgap Voltage Reference with CTAT Compensation (개선된 CTAT 보상을 가지는 저전압 CMOS Bandgap Voltage Reference)

  • Kim, Jae-Bung;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.753-756
    • /
    • 2012
  • In this paper, a modified low-votlage CMOS bandgap voltage reference with CTAT compensation is presented. The proposed structure doesn't use PTAT current. The proposed structure is more simple than the existing structure and doesn't use the eighteen BJT. The modified low-votlage CMOS bandgap voltage reference with CTAT compensation has been successfully verified in a standard 0.18um CMOS process. The simulation results have confirmed that, with the minimum supply voltage of 1.25V, the output reference voltage at 549mV has a temperature coefficient of 12$ppm/^{\circ}C$ from $0^{\circ}C$ to $100^{\circ}C$.

Energy Management Method of DC Microgrids by Using Voltage Compensation Term (전압 변동 보상항을 이용한 직류 마이크로그리드의 에너지 관리 기법)

  • Ko, Byoung-Sun;Lee, Gi-Young;Kim, Seok-Woong;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.328-335
    • /
    • 2018
  • An energy management method of DC microgrids using voltage compensation term is proposed in this study. Droop control is often implemented to operate the DC microgrid. However, the droop control necessarily generates voltage variation. Energy flow is also difficult to control because the droop control mainly focuses on proportional load sharing. To solve these problems, the voltage compensation term based on the low-bandwidth communication is used to determine the operating band of the converter. Energy management and voltage variation minimization can be achieved by judging the operating band according to the magnitude of voltage compensation term. The validity of the proposed method is verified by simulation and experiments.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-leg Three-Phase PWM Inverters (2-leg 3상 PWM 인버터의 출력전압에서 직류링크 리플 전압의 영향 보상)

  • Kim, Young-Sin;Lee, Dong-Choon;Seok, Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.572-574
    • /
    • 2005
  • In this paper, a compensation scheme for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, without which compensation scheme the three-phase output voltage and current are much distorted. The proposed scheme has been verified by experimental results.

  • PDF