• 제목/요약/키워드: Voltage collapse

검색결과 98건 처리시간 0.033초

An Economic Evaluation under Thailand Feed in Tariff of Residential Roof Top Photovoltaic Grid Connected System with Energy Storage for Voltage Stability Improving

  • Treephak, Kasem;Saelao, Jerawan;Patcharaprakiti, Nopporn
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.120-128
    • /
    • 2015
  • In this paper, Residential roof top photovoltaic system with 9.9 kW design is proposed. The system composed of 200 Watts solar array 33 panels connecting in series 10 strings and parallels 3 strings which have maximum voltage and current are 350 V and 23.8 A. The 10 kW sinusoidal grid-connected inverter with window voltage about 270-350 is selected to convert and transfer DC Power to AC Power at PCC (Point of Common Coupling) of power system following to utility standard. However the impact of fluctuation and uncertainty of weather condition of PV may decrease the voltage stability and voltage collapse of power system. In order to solve this problem the energy storage such 120 V 1200 Ah battery bank and 30 kVAR capacitor are designed for voltage stability control. The other expensed for installing the system such battery charger, cable, accessories and maintenance cost are concerned. The economic analysis by using investment from money loan with interest about 7% and use own money which loss income of deposit about 3% are calculated as 671,844 and 547,044 for PV system with energy storage and non energy storage respectively. The solar energy from PV is about 101,616 Bath per year which evaluated by using the value of $5kWh/m^2/day$ from average peak sun hour (PSH) of the Thailand and 6.96 Bath/kWh of Feed in Tariff Incentive. The payback periods of four scenarios are proposed follow as i) PV system with energy storage and use loan money is 15 years ii) PV system with no energy storage and use loan money is 10 years iii) PV system with energy storage and use deposit money is 9 years iv) PV system with energy storage and use deposit money is 7 years. In addition, the other scenarios of economic analysis such no FIT support and other type of economic analysis such NPV and IRR are proposed in this paper.

Optimal Placement of Distributed Generators in Radial Distribution System for Reducing the Effect of Islanding

  • K, Narayanan.;Siddiqui, Shahbaz A.;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.551-559
    • /
    • 2016
  • The present trend of increasing the penetration levels of Distributed Generator (DG) in the distribution network has made the issue of Islanding crucial for the reliable operation of the network. The islanding, if not detected early may lead to the collapse of the system as it can drive the distribution system to the cascaded failure. In this paper, an extensive study of the effect of DG placement and sizing is performed by dividing the system into different zones to obtain a reduced effect of islanding. The siting and sizing of DG is carried out to improve the overall voltage profile or/and reduction in active power loss using two stage Genetic Algorithm (GA). In the first stage a basic knockout selection is considered and the best population is taken for next stage, where roulette selection for crossover and mutation is performed for optimal placement and sizing of DGs. The effect of the islanding, due to load variations is reduced by optimal siting and sizing of DG. The effectiveness of the proposed scheme is tested on the IEEE 33 and 69 radial bus systems and the results obtained are promising.

전철시스템에서의 보호시스템에 관한 연구 (A study on the protection system in electrified railways system)

  • 이희용;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1342-1346
    • /
    • 2004
  • Recently, the load increasement and regenerative system of electrified railway system make a difficult to distinguish between the load current and fault current and it need a new intelligent protection system. The failure of traction system cause collapse of the other systems from high tension current. The over current from abnormal situation produces high tension current flow, high temperature are, voltage instability and current cutting, and break down railway systems. Protective system of traction system playa role of which detect and isolate failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

최단전압붕괴점을 계산하는 개선된 직접법 (Improved Direct Method for Computing a Closest Voltage Collapse Point)

  • 남해곤;송충기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.231-234
    • /
    • 1997
  • This paper presents improved direct method for calculating the closest saddle node bifurcation (CSNB) point, which is also applicable to the selection of appropriate load shedding, reactive power compensation point detection. The proposed method reduced dimension of nonlinear equation compared with that of Dobson's direct method. The improved direct method, utilizing Newton Iterative method converges very quickly. But it diverges if the initial guess is not very close to CSNB. So the direct method is performed with the initial values obtained by carrying out the iterative method twice, which is considered most efficient at this time. Since sparsity techniques can be employed, this method is a good choice to a large scale system on-line application. Proposed method has been tested for 5-bus, New England 30-bus system.

  • PDF

금속이온 착체에 의한 IMI-O 고분잔 LB막의 전기적 특성 (Electrical Properties of IMI-O Polymer LB Films in Complexed Metal Ion)

  • 정상범;유승엽;박재철;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1519-1521
    • /
    • 1997
  • In this paper, poly (N-(2-4-imidazolyl) ethyl) maleimide-alt-1-octadecene (IMI-O) polymer which can complex metal ion was used to confirm the possibility of molecular device made by Langmuir-Blodgett method. Metal/Insulator/Metal (MIM) device was fabricated for investigation of electric properties. In the ${\pi}$-A isotherm, surface pressure at collapse point was different as to the molecular weight of metal ion complexed respectively, In I-V characteristics, currents of MiM devices were different at the same voltage. It was thought that phenomena was occurred by interaction between function group and metal ion.

  • PDF

전력조류계산을 위한 새로운 유전알고리즘 적용기법 (A New Application Technique of Genetic Algorithm for Power Flow)

  • 박순재;채명석;임한석;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.790-793
    • /
    • 1997
  • The most of conventional power flow(PF) calculations which adopt the well-known numerical methods such as Newton-Raphson method often diverge in certain critical cases like near the voltage collapse point. Some Approaches have been reported for the application of Genetic Algorithm(GA) to PF problem to overcome the disadvantages mentioned above. This paper presents a new application technique of GA for PF problem, in which some improvements and modifications are made ; modification of fitness function, improvements on crossover method, mutation law and convergence criterion, introduction of reactive power check routine. Some case studies with IEEE 5, 6, 14 bus systems are performed to show the performance of proposed algorithm.

  • PDF

RC 구조물의 Eddy Current 기반 철근부식 감지 센서에 관한 실험적 연구 (Experimental Study on Eddy Current based-on Corrosion Detection Sensor for RC structure)

  • 양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.260-261
    • /
    • 2019
  • Corrosion of rebar embedded reinforced concrete is the main cause of collapse and degradation of reinforced concrete structure that many researches are recently focused on these works. Methods of evaluating rebar corrosion are divided into physical and electrochemical methods. However, the result of Conventional methods are less reliable due to effect of internal and external environments. In this study, rebar corrosion detection sensor for embedded rebar of RC structures is evaluated through immersion test in NaCl solustion for 160hours. From the results, Rebar corrosion was ongoing and corrosion products are produced on rebar surface. The voltage is decreased as amount of corrosion production increased.

  • PDF

지역별 시송전선로 검토 및 검증방안에 관한 연구 (A study on the investigation and the verification method of the regional restorative transmission)

  • 이남호;송인준;조경보;곽노홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.187-189
    • /
    • 2003
  • Service restoration following a complete or partial collapse starts with reenergizing a transmission line from black-start generators. Voltage problems can arise from Ferranti effect as unloaded transmission line is reenergized and has to be required to consider it when KPX makes a restorative plan on the massive blackout. This paper presents the investigation of seven regional blackstart lines which are chosen by KPX restorative plan and suggests the verification method for the new designed line according to the system modification.

  • PDF

고전압 펄스 전기장 처리에 의한 Saccharomyces cerevisiae의 생리적 변화 (Physiological Changes of Saccharomyces cerevisiae by High Voltage Pulsed Electric Field Treatments)

  • 박희란;윤소정;박한설;신정규
    • 한국식품과학회지
    • /
    • 제45권5호
    • /
    • pp.590-597
    • /
    • 2013
  • 고전압 펄스 전기장 기술은 가열 공정을 대체할 수 있는 비가열 살균기술로서 꾸준한 연구가 이루어지고 있는 기술이다. 본 실험에서는 미생물의 생리적 측면에서 고전압 펄스 전기장 처리에 의한 효모의 생리적 변화를 살펴보았다. 내염성의 변화를 측정한 결과 사멸하지 않은 세포의 90-99% 이상이 세포 손상에 의해 내염성을 소실하였으며, 내염성을 회복하는데 약 4-6시간의 시간이 걸렸다. 고전압 펄스 전기장 처리 초기에는 세포 내외의 pH 구배(${\Delta}pH$)가 차이가 컸으나 처리시간이 증가함에 따라 그 차이가 감소하였다. 이는 세포의 pH 항상성을 유지시키는 $H^+$-traslocation 기능을 담당하고 있는 $H^+$-ATPase 활성이 소실되었거나 세포막 자체가 손상되어 pH 항상성을 잃어버렸기 때문으로, 이는 고전압 펄스 전기장 처리한 세포의 $H^+$-ATPase의 활성이 초기부터 크게 감소하는 것으로 확인할 수 있었다. 또한 세포의 해당활성이 고전압 펄스 전기장 처리에 의해 크게 감소하여 세포의 대사 기능이 손상되는 것을 확인하였다.

Centralized Control Algorithm for Power System Performance using FACTS Devices in the Korean Power System

  • Kang, Sang-Gyun;Seo, Sang-Soo;Lee, Byong-Jun;Chang, Byung-Hoon;Myung, Ro-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.353-362
    • /
    • 2010
  • This paper presents a centralized control algorithm for power system performance in the Korean power system using Flexible AC Transmission Systems (FACTS) devices. The algorithm is applied to the Korean power system throughout the metropolitan area in order to alleviate inherent stability problems, especially concerns with voltage stability. Generally, control strategies are divided into local and centralized control. This paper is concerned with a centralized control strategy in terms of the global system. In this research, input data of the proposed algorithm and network data are obtained from the SCADA/EMS system. Using the full system model, the centralized controller monitors the system condition and decides the operating point according to the control objectives that are, in turn, dependent on system conditions. To overcome voltage collapse problems, load-shedding is currently applied in the Korean power system. In this study, the application of the coordination between FACTS and switch capacitor (SC) can restore the solvability without load shedding or guarantee the FV margin when the margin is insufficient. Optimal Power Flow (OPF) algorithm, for which the objective function is loss minimization, is used in a stable case. The results illustrate examples of the proposed algorithm using SCADA/EMS data of the Korean power system in 2007.