• Title/Summary/Keyword: Voltage Disturbance

Search Result 248, Processing Time 0.022 seconds

Hierarchical Voltage Control of a Wind Power Plant Using the Adaptive IQ-V Characteristic of a Doubly-Fed Induction Generator

  • Kim, Jinho;Park, Geon;Seok, Jul-Ki;Lee, Byongjun;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.504-510
    • /
    • 2015
  • Because wind generators (WGs) in a wind power plant (WPP) produce different active powers due to wake effects, the reactive power capability of each WG is different. This paper proposes a hierarchical voltage control scheme for a WPP that uses a WPP controller and WG controller. In the proposed scheme, the WPP controller determines a voltage error signal by using a PI controller and sends it to a doubly-fed induction generator (DFIG). Based on the reactive current-voltage ($I_Q-V$) characteristic of a DFIG, the DFIG injects an appropriate reactive power corresponding to the voltage error signal. To enhance the voltage recovery capability, the gains of the $I_Q-V$ characteristic of a DFIG are modified depending on its reactive current capability so that a DFIG with greater reactive current capability may inject more reactive power. The proposed scheme enables the WPP to recover the voltage at the point of common coupling (PCC) to the nominal value within a short time after a disturbance by using the adaptive $I_Q-V$ characteristics of a DFIG. The performance of the proposed scheme was investigated for a 100 MW WPP consisting of 20 units of 5 MW DFIGs for small and larger disturbances. The results show the proposed scheme successfully recovers the PCC voltage within a short time after a disturbance.

피드포워드 제어기를 사용한 동기발전기의 과도특성 개선 (Improvement of Transient Performance of Synchronous Generator using Feedforward Controller)

  • 안영주
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.

Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torches

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.591-598
    • /
    • 2011
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torches. A series resonant half-bridge topology is presented as a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. A plasma torch rated at 3MW, 2kA and having a physical size of 1m is selected to be the high enthalpy source for a waste disposal system. The steady-state and transient operations of a plasma torch are simulated. The parameters of a Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. The circuit simulation waveform shows that the ripple of the arc current can be maintained within ${\pm}10%$ of its rated value under the presence of a load disturbance. This power conversion configuration provides a high enough ignition voltage, around 5KA, during the ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

Enhanced Dynamic Response of SRF-PLL System for High Dynamic Performance during Voltage Disturbance

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.369-374
    • /
    • 2011
  • Usually, a LPF (low pass filter) is used in the feedback loop of a SRF (synchronous reference frame) - PLL (phase locked loop) system because the measured grid voltage contains harmonic distortions and sensor noises. In this paper, it is shown that the cut-off frequency of the LPF should be designed to suppress the harmonic ripples contained in the measured voltage. Also, a new design method for the loop gain of the PI-type controller in the SRF-PLL is proposed with consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and the PI controller gain are designed in coordination according to the steady state and dynamic performance requirements. Furthermore, in the proposed method, the controller gain and the LPF cut-off frequency are changed from their normal value to a transient value when a voltage disturbance is detected. This paper shows the feasibility and usefulness of the proposed methods through the computer simulations and experimental results.

친환경 Ultra-capacitor에 의한 순시전압강하의 직렬전압보상 시스템 (Series Voltage Compensation Systems for Voltage Sag by Using an Environmentally Friendly Ultra-capacitor)

  • 손진근;전희종
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.763-769
    • /
    • 2009
  • A series voltage compensation(SVC) system is a power-electronics controller that can protect sensitive loads from disturbance in the supply system. Especially, voltage sags are considered the dominant disturbances affecting the power quality. This paper dealt with a system of off-line type voltage sag compensation by using a bi-directional DC/DC converter of environmentally friendly ultra-capacitor. This capacitor is attached to the DC link of SVC through the high-efficiency DC/DC converter in order to compensate the DC link voltage drop during short-term power interruption as voltage sags. Therefore, in this paper, a DC/DC converter to control high-efficiency energy of ultra-capacitor and voltage sag detection algorithm of off-line type SVC systems are newly introduced. According to the results of experimental of prototype system, it is verified that the proposed system has effectiveness of voltage sag compensation using an ultra-capacitor.

컴퓨터 응용 부하들을 위한 전압 외란 검출 방법 (A Voltage Disturbance Detection Method for Computer Application Lods)

  • 이상훈;최재호
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.584-591
    • /
    • 2000
  • 컴퓨터와 같은 민감한 부하를 전압강하나 정전과 같은 전원 장애로부터 보호하기 위하여 전력보상장치가 설­치되어 왔다. 전력보상장치의 경우 계통과의 연계를 위해 대부분 정지형 스위치를 이용하고 있으며, 이러한 정지형 스위치의 전환동작은 매우 중요한 부분을 차지하고 있다. 그간 전략보상장치의 구조나 제어에 관한 연구는 활발하게 진행되어 왔으나 전력보상장치의 운전을 시작하기 위한 전원 장애의 감지에 판한 연구는 매우 드문게 현실이다. 따라서 본 논문에서는 정지형 스위치 절환동작을 위해 CBEMNITIC 커브를 이용하여 컴퓨터 응용부하판 위한 새보운 전원 장애 검출 암고리즘을 제안한다. 제안된 검출 알고리즘은 동기 좌표계에서 직류 값으으 변환된 삼상 순시 전압값을 동작 기준값과 비교하는 방법을 사용하여 빠른 검출 시간을 가지도록 하였다. 그리고, 간단한 1차 디지텔 필터를 삽입하여 잡음에 강인하도록 선거하였다. 이러한 필터에 의해 나타나는 위상지연 및 이득감소를 각각 전달함수를 이용한 수식적인 해석과 오차의 정규화를 통해 보상하였다. 마지막으로 ACSL를 이용한 시뮬레이션파 실험을 통해 제안된 알고리즘의 타당성을 입증하였다.

  • PDF

A Novel Dead-Time Compensation Method using Disturbance Observer

  • Youn, Myung-Joong;Moon, Hyung-Tae;Kim, Hyun-Soo
    • Journal of Power Electronics
    • /
    • 제2권1호
    • /
    • pp.55-66
    • /
    • 2002
  • A new on-line dead-time compensation method for a permanent magnet (PM) synchronous motor drive is proposed. Using a simple disturbance observer without any additional circuit and off-line experimental measurement, disturbance voltages in the synchronous reference dq frame caused by the dead time and non-ideal switching characteristics of power devices are estimated in an on-line manner and fed to voltage references in order to compensate the dead-time effects. The proposed method is applied to a PM synchronous motor drive system and implemented by using software of a digital signal processor (DSP) TMS320C31. Simulations and experiments are carried out for this system and the results well demonstrate the effectiveness of the proposed method.

Incremental Passivity Based Control for DC-DC Boost Converters under Time-Varying Disturbances via a Generalized Proportional Integral Observer

  • He, Wei;Li, Shihua;Yang, Jun;Wang, Zuo
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.147-159
    • /
    • 2018
  • In this paper, the voltage tracking control of a conventional DC-DC boost converter affected by unknown, time-varying circuit parameter perturbations is investigated. Based on the fundamental property of incremental passivity, a passivity based control law is designed. Then, to obtain a better disturbance rejection property, two generalized proportional integral (GPI) observers are employed to estimate the time-varying uncertainties in the output voltage and inductor current channels, and the estimated values are applied as feedforward compensation. Moreover, the global trajectory tracking performance of a system with disturbances is ensured under the composite controller. Finally, simulation and experiment studies are provided to demonstrate the feasibility and effectiveness of the proposed method. The results show that the proposed controller delivers a promising disturbance rejection capability as well as a good nominal tracking performance.

배터리 응용을 위한 1.5V 단일전원 256Kb EEPROM IP 설계 (Design of 256Kb EEPROM IP Aimed at Battery Applications)

  • 김영희;김일준;하판봉
    • 한국정보전자통신기술학회논문지
    • /
    • 제10권6호
    • /
    • pp.558-569
    • /
    • 2017
  • 본 논문에서는 MCU 내장형 1.5V 단일전원 256Kb EEPROM IP는 배터리 응용을 위해 설계되었다. 기존의 body-potential 바이어싱 회로를 사용하는 cross-coupled VPP (Boosted Voltage) 전하펌프회로는 erase와 program 모드에서 빠져나올 때 5V cross-coupled PMOS 소자에 8.53V의 고전압이 걸리면서 junction breakdown이나 gate oxide breakdown에 의해 소자가 파괴될 수 있다. 그래서 본 논문에서는 cross-coupled 전하펌프회로의 출력 노드는 VDD로 프리차징시키는 동시에 펌핑 노드들을 각 펌핑 단의 입력전압으로 프리차징하므로 5V PMOS 소자에 5.5V 이상의 고전압이 걸리지 않도록 하므로 breakdown이 일어나는 것을 방지하였다. 한편 256Kb을 erase하거나 program하는 시간을 줄이기 위해 all erase, even program, odd program과 all program 모드를 지원하고 있다. 또한 cell disturb 테스트 시간을 줄이기 위해 cell disturb 테스트 모드를 이용하여 256Kb EEPROM 셀의 disturb를 한꺼번에 인가하므로 disturb 테스트 시간을 줄였다. 마지막으로 이 논문에서는 erase-verify-read 모드에서 40ns의 cycle 시간을 만족하기 위해 CG disable 시간이 빠른 CG 구동회로는 새롭게 제안되었다.

dq 좌표변환을 이용한 전력외란 보상 연구 (A Study of Pourer Quality Disturbance Compensation using dq Transformation)

  • 이교성;이용제;김도훈;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.286-289
    • /
    • 2002
  • In this paper, we use the PI dual control using do transformation(dq stationary frame and dq synchronous rotating frame) for series voltage sag and swell compensation algorithm. Analysis, simulation results are presented for voltage sags and swells on a three-phase unbalanced voltage source.

  • PDF