Super-Lift DC-DC Converters: Graphical Analysis and Modelling

  • Zhu, Miao;Luo, Fang Lin
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.854-865
    • /
    • 2009
  • Super-lift dc-dc converters are a series of advanced step-up dc-dc topologies that provide high voltage transfer gains by super-lift techniques. This paper presents a developed graphical modelling method for super-lift converters and gives a thorough analysis with a consideration of the effects caused by parasitic parameters and diodes' forward voltage drop. The general guidelines for constructing and deriving graphical models are provided for system analysis. By applying it to examples, the proposed method shows the advantages of high convenience and feasibility. Both the circuit simulation and experimental results are given to support the theoretical analysis.

Steady-State Analysis of ZVS and NON-ZVS Full-Bridge Inverters with Asymmetrical Control for Induction Heating Applications

  • Yachiangkam, Samart;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.544-554
    • /
    • 2015
  • This paper presents a steady-state operation analysis of full-bridge series-resonant inverters focusing on the distorted load current due to low-quality-factor resonant circuits in induction heating and other applications. The regions of operation based on the zero-voltage switching (ZVS) and non-zero-voltage switching (NON-ZVS) operations of the asymmetrical voltage-cancellation control technique are identified. The effects of a distorted load current under a wide range of output powers are also analyzed for achieving a precise ZVS operating region. An experimental study is performed with a 1kW prototype. Simulation and experimental studies have confirmed the validity of the proposed method. An efficiency comparison between the variable frequency method and the conventional fixed-frequency method is provided.

A Voltage Disturbance Detection Method for Computer Application Loads (컴퓨터 응용 부하들을 위한 전압 외란 검출 방법)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.245-248
    • /
    • 2000
  • In this paper a novel method for voltage disturbance detection is presented. This is a instantaneous detection method using normalized error get in synchronous reference frame and also it is implemented in digital. Feedback noise the problem of digital implementation is removed by a digital filter of which the time delay is compensated through numerical analysis.

  • PDF

Analysis of Normal Induced Voltage on Telecommunication Line according to Earth Resistivity in Distrbution Lines (배전선로에서의 대지 저항율에 따른 통신선 상시 유도전압 분석)

  • Kim, Hyoun-Su;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seung-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.223_224
    • /
    • 2009
  • This paper investigates a normal induced voltage according to earth resistivity from distribution lines using calculation method of the normal induced voltage on telecommunication line. The induced voltage according to earth resistivity from distribution lines is verified by vector analysis and EMTP(Electro-Magnetic Transients Program).

  • PDF

Techno-Economic Optimization of a Grid-Connected Hybrid Energy System Considering Voltage Fluctuation

  • Saib, Samia;Gherbi, Ahmed;Kaabeche, Abdelhamid;Bayindir, Ramazan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.659-668
    • /
    • 2018
  • This paper proposes an optimization approach of a grid-connected photovoltaic and wind hybrid energy system including energy storage considering voltage fluctuation in the electricity grid. A techno-economic analysis is carried out in order to minimize the size of hybrid system by considering the benefit-cost. Lithium-ion battery type is used for both managing the electricity selling to the grid and reducing voltage fluctuation. A new technique is developed to limit the voltage perturbation caused by the solar irradiance and the wind speed through determining the state-of-charge of battery for every hour of a day. Improved particle swarm optimization (PSO) methods, referred to as FC-VACPSO which combines Fast Convergence Particle Swarm Optimization (FCPSO) method and Variable Acceleration Coefficient Based Particle Swarm Optimization (VACPSO) method are used to solve the optimization problem. A comparative study has been performed between standard PSO method and PSO based methods to extract the best size with the benefit cost. A sensitivity analysis has been studied for different kinds and costs of batteries, by considering variable and constant state-ofcharge of battery. The simulations, performed under Matlab environment, yield good results using the FC-VACPSO method regarding the convergence and the benefit cost of the hybrid system.

Analysis and Design of a Current-fed Two Inductor Bi-directional DC/DC Converter using Resonance for a Wide Voltage Range

  • Noh, Yong-Su;Kim, Bum-Jun;Choi, Sung-Chon;Kim, Do-Yun;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1634-1644
    • /
    • 2016
  • In this paper, a current-fed two-inductor bi-directional DC/DC converter using resonance (CF-TIBCR) and its design method are proposed. The CF-TIBCR has characteristics of low current ripple and a high current rating because of two separated inductors. Also, it achieves zero voltage switching for all switches and zero current switching for switches of a low voltage stage by using the resonant tank. Besides, a voltage spike problem in conventional current-fed converters is solved without the need for an additional snubber or clamping circuits. As a result, the CF-TIBCR features high step-up and high efficiency. Since the proposed converter has difficulty achieving the soft-switching condition when the converter requires the low voltage transfer ratio, a method that varies the number of resonant cycles is adopted to extend the output voltage range with satisfying the soft-switching condition. The principles of the operation characteristics are presented with a theoretical analysis, and the proposed converter is verified through results of an experiment using a laboratory prototype.

Design and Analysis of 20 W Class LED Converter Considering Its Control Method (제어 방식에 따른 20 W급 LED Converter 설계 및 분석)

  • Jeong, Young-Gi;Kim, Sung-Hyun;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • In this paper, by designing 20 W class driving circuit for driving high-power LED (Light Emitting Diode), we are going to comparatively carry out the analysis of characteristics for power circuit according to each design method. In this case, 200 V 60 Hz was performed as input data. The electrical characteristics such as voltage, current and ripple are checked for constant current circuit and constant voltage circuit in the LED module. In addition, as the ripple has an influence on illumination of LED light, low temperature working (-20 [$^{\circ}C$]) and high temperature working(80 [$^{\circ}C$]) are measured to make sure the ripple characteristics in accordance with temperature. In low temperature operation -20 [$^{\circ}C$] measurements, both constant current circuit and constant-voltage circuit were less impacted on input fluctuation, whereas in the high temperature operation 80 [$^{\circ}C$], current voltage in constant voltage circuit was surge after 430 [hour]. Voltage current ripple of constant current circuit was much less than constant voltage circuit, therefore we can show that constant current circuit is more stable.

Analysis and Design of Function Decoupling High Voltage Gain DC/DC Converter

  • Wei, Yuqi;Luo, Quanming;Lv, Xingyu;Sun, Pengju;Du, Xiong
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.380-393
    • /
    • 2019
  • Traditional boost converters have difficulty realizing high efficiency and high voltage gain conversion due to 1) extremely large duty cycles, 2) high voltage and current stresses on devices, and 3) low conversion efficiency. Therefore, a function decoupling high voltage gain DC/DC converter composed of a DC transformer (DCX) and an auxiliary converter is proposed. The role of DCX is to realize fixed gain conversion with high efficiency, whereas the role of the auxiliary converter is to regulate the output voltage. In this study, different forms of combined high voltage gain converters are compared and analyzed, and a structure is selected for the function decoupling high voltage gain converter. Then, topologies and control strategies for the DCX and auxiliary converter are discussed. On the basis of the discussion, an optimal design method for circuit parameters is proposed, and design procedures for the DCX are described in detail. Finally, a 400 W experimental prototype based on the proposed optimal design method is built to verify the accuracy of the theoretical analysis. The measured maximum conversion efficiency at rated power is 95.56%.

Improved dc-link capacitor voltage control of Distribution Static Compensator (배전용 정지형 보상기의 개선된 직류단 커패시터 전압제어)

  • Kim, Ho-Yeol;Choi, Jong-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.466-467
    • /
    • 2010
  • Researches about DSTATCOM are mainly divided two parts, one is the calculation of the load-side average active power and dc-link capacitor average voltage, the other part is the current control. This paper proposes a calculation of dc-link capacitor average voltage using improved method instead of conventional method using LPF (low pass filter). Through the theoretical analysis and simulation under unbalance loads and non-linear load, the proposed method is verified.

  • PDF

Novel Single-State PWM Technique for Common-Mode Voltage Elimination in Multilevel Inverters

  • Nguyen, Nho-Van;Quach, Hai-Thanh;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.548-558
    • /
    • 2012
  • In this paper, a novel offset-based single-state pulse width modulation (PWM) method for achieving zero common-mode voltage (CMV) and reducing switching losses in multilevel inverters is presented. The specific active switching state of the zero common-mode (ZCM) voltage that approximates the reference voltage can be deduced from the switching state sequence of the reduced CMV phase disposition PWM (CMV PD PWM) method. From the reference leg voltages for the zero common-mode voltage, an N-to-2-level transformation defines a virtual two-level inverter and the corresponding nominal leg voltage references. The commutation process of the reduced CMV PD PWM method in a multilevel inverter and its outputs can be simply followed in a nominal switching time diagram for the virtual inverter. The characteristics of the reduced CMV PD PWM and the single-state PWM for zero common-mode voltage are analyzed in detail in this paper. The theoretical analysis of the proposed PWM method is verified by experimental results.