• Title/Summary/Keyword: Voltage

Search Result 28,793, Processing Time 0.049 seconds

A low noise PLL with frequency voltage converter and loop filter voltage detector (주파수 전압 변환기와 루프 필터 전압 변환기를 이용한 저잡음 위상고정루프)

  • Choi, Hyek-Hwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.37-42
    • /
    • 2021
  • This paper presents a jitter and phase noise characteristic improved phase-locked loop (PLL) with loop filter voltage detector(LFVD) and frequency voltage converter(FVC). Loop filter output voltage variation is determined through a circuit made of resistor and capacitor. The output signal of a small RC time constant circuit is almost the same as to loop filter output voltage. The output signal of a large RC time constant circuit is the average value of loop filter output voltage and becomes a reference voltage to the added LFVD. The LFVD output controls the current magnitude of sub-charge pump. When the loop filter output voltage increases, LFVD decreases the loop filter output voltage. When the loop filter output voltage decreases, LFVD increases the loop filter output voltage. In addition, FVC also improves the phase noise characteristic by reducing the loop filter output voltage variation. The proposed PLL with LFVD and FVC is designed in a 0.18um CMOS process with 1.8V power voltage. Simulation results show 0.854ps jitter and 30㎲ locking time.

Voltage Control of ULTC and Distributed Generations in Distribution System (분산전원이 연계된 배전계통에서 ULTC와 분산전원의 전압제어)

  • Jeon, Jae-Geun;Won, Dong-Jun;Kim, Tae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2206-2214
    • /
    • 2011
  • LDC(Line Drop Compensation) is widely used in controlling ULTC(Under Load Tap Changer) output voltage at distribution substation. However, LDC may experience some difficulties in voltage control due to renewable energy resources and distributed generations. Therefore, more advanced voltage control algorithm is necessary to deal with these problems. In this paper, a modified voltage control algorithm for ULTC and DG is suggested. ULTC is operated with the voltages measured at various points in distribution system and prevents overvoltage and undervoltage in the distribution feeders. Reactive power controller in DG compensates the voltage drop in each distribution feeders. By these algorithms, the voltage unbalance between feeders and voltage limit violation will be reduced and the voltage profile in each feeder will become more flat.

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

Measurement Technique of Required Spark Voltage Using Primary Ignition Voltage and Misfire Application in a SI Engine (SI엔진에서 점화 1차 전압을 이용한 방전요구전압의 측정기법과 실화적용에 관한 연구)

  • 박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.10-19
    • /
    • 1999
  • In this study , a simple method has been developed to detect the required spark voltage by using the primary spark voltage instead of the secondary spark voltage. Through engine motoring experiments, this method testified to be quite satisfactory. Though the required spark voltage is affected by many in-cylinder conditions, temperature is one of the most important factors. The temperature increases significantly by combustion and the required spark voltage also changes by the temperature during the expansion stroke. On the basis of this fact, misfire can be monitored by comparing the required spark voltage between compression stroke and expansion stroke. So, in this study, two step ignition method is introduced to monitor combustion at expansion stroke. The test result shows that this method can be used to detect complex misfire pattern.

  • PDF

Torque Control of Synchronous Reluctance Motor using DC Link voltage Synthesis (DC Link 전압 합성을 이용한 동기형 릴럭턴스 전동기 토크 제어)

  • Kim, Seung-Joo;Ahn, Joon-Seon;Kim, Ki-Chan;Go, Sung-Chul;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.19-21
    • /
    • 2006
  • This paper presents the control method that inverter output keeps to linear to reference voltage of Synchronous Reluctance Motor using DC Link voltage Synthesis. The Inverter output voltage cannot be displayed to linear about inverter reference voltage if Real DC Link voltage is different from DC Link voltage of PWM amplitude. Also, the overmodulation that there is linearity broken if reference voltage is out of range that inverter can output voltage. Torque ripple generates the vibration and noise of a motor. This paper proposes the control method so that torque ripple decreases and the linearity of inverter output keeps using the DC Link voltage Synthesis.

  • PDF

Compensation of the secondary voltage of a three winding coupling capacitor voltage transformer (3권선 CCVT의 2차 전압 보상 방법)

  • Kang, Yong-Cheol;Kim, Yeon-Hee;Zheng, Tai-Ying;Jang, Sung-Il;Kim, Yong-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.18-20
    • /
    • 2007
  • A coupling capacitor voltage transformer (CCVT) is used in an extra high voltage power system to obtain the standard low voltage signal for protection and measurement. To suppress the effects of ferro-resonance more effectively, a three winding CCVT is used. This paper proposes an algorithm for compensating the secondary voltage of the three winding CCVT. With the secondary voltage of the three winding CCVT, the secondary and tertiary currents are obtained; the primary winding current is obtained by considering non-linear characteristics of the core; the voltage across the capacitor and the inductor are calculated and then added to the measured voltage to compensate the secondary voltage. Test results indicate that the algorithm can reduce the errors of the three winding CCVT significantly.

  • PDF

A Study on the Voltage Stability Control Scheme using Real-time Monitoring Data (실시간 감시 정보를 이용한 전압안정도 제어 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.206-212
    • /
    • 2017
  • In this paper, using the power system information obtained from real-time monitoring device, to analyze the voltage stability margin index and described the voltage stability control scheme for voltage stability enhancement. Based on the utilization of the voltage stability monitoring index based on local information provided by the PMU(Phasor Measurement Unit), the purpose of the plan is to control the system stably in real time. In order to apply the load control scheme, the voltage stability margin is calculated using the data acquired through the PMU installed in each load bus. If the voltage drops below a certain level, load control is performed for each. The effectiveness of the voltage stability control measures is applied to the actual KEPCO system to analyze the effectiveness.

Controller Design of Buck-Boost Converter with Constant Voltage Output (정 전압 출력을 갖는 벅-부스트 컨버터의 제어기 설계)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.42-50
    • /
    • 2015
  • The Buck-Boost converter consisted of two switches is more expensive than the conventional Buck converter, because of the increase of the components. However, it can control the DC voltage depending on the requested load voltage without additional circuits, because it can control the voltage under the relatively wide range of the load. Additionally, it can control the output voltage constantly under the variation of the input voltage. In the paper two control loops consisted of current and voltage control are designed. When two controllers are operated at the same time the problem of the output voltage is occurred. Therefore, the solution of the output voltage problem is proposed. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype system rated at 1kVA.

Performance Analysis of a Three-Phase Parallel Active Power Filter which Compensates PCC Voltage and the Unbalanced Loads

  • Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.9-18
    • /
    • 2001
  • The performance analysis of a three-phase parallel active power filter that compensates PCC voltage and the unbalanced loads is presented in this paper. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. Firstly, it operates as a conventional active filter with reactive power compensation when PCC voltage is within the 15% voltage drop range. Secondly, it operates as a voltage compensator when PCC voltage is not within the 15% voltage drop range. And both APF and voltage compensator compensate asymmetries caused by nonlinear loads. Finally, two methods of detecting the negative sequence are reviewed, and the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rate at 10KVA.

  • PDF

A Parallel Processing Uninterruptible Power Supply for Sudden Voltage Fluctuation for Computer Applications

  • Lee, Su-Won;Ko, Sung-Hun;Lee, Seong-Ryong;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.287-289
    • /
    • 2009
  • This paper deals with a parallel processing uninterruptible power supply (UPS) for sudden voltage fluctuation in computer applications to integrate power quality improvement, load voltage stabilization and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, only one voltage-controlled voltage source inverter (VCVSI) is used. The system provides sinusoidal voltage at the fundamental value of 220V/60Hz for the load during abnormal utility power conditions or grid failure. Also, the system can be operated to mitigate the harmonic current and voltage demand from nonlinear loads and provide voltage stabilization for loads when sudden voltage fluctuation occur, such as sag and swell. System operation simulation demonstrates that the system protects against outages caused by abnormal utility power conditions and sudden voltage fluctuations and changes.

  • PDF