• Title/Summary/Keyword: Visual sensitivity

Search Result 379, Processing Time 0.029 seconds

Visual Discomfort and Visual Fatigue: Comparing Head-Mounted Display and Smartphones

  • Han, Jungmin;Bae, Seon Hee;Suk, Hyeon-Jeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.293-303
    • /
    • 2017
  • Objective: This study aims to evaluate visual discomfort and visual fatigue caused by watching HMD and smartphones by conducting both subjective and objective measure. Background: With the rapid development of mobile Head-Mounted Display (HMD), the problem of visual discomfort and visual fatigue caused by watching Virtual Reality (VR) contents became a crucial concern for consumers and manufacturers, especially given that the casing of mobile HMD keeps the phone at a specified distance from the lenses that is close to the eyes. Method: Two smartphones were chosen for a preliminary study: LG G5 and Galaxy S7. As for a main study, iPhone 6S and Galaxy S7 were used. After being exposed to the selected clips, participants were asked to answer Simulator Sickness Questionnaire (SSQ) and went through optometric tests that measure tear break-up time, spherical equivalent, and contrast sensitivity. Results: The subjective assessments indicate that HMD causes more visual discomfort compared to watching a smartphone. Furthermore, the experimental result confirms that watching a HMD causes more eye dryness compared to smartphones. Conclusion: The result of the study compared visual discomfort and visual fatigue of two different displays, HMD and smartphone, and confirmed that watching HMD causes more visual discomfort and visual fatigue. Application: Ultimately, this study could help manufacturers understand the strengths and weaknesses of different display forms, providing guidance for an effective application of HMD.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

Linear Sub-band Decomposition-based Pre-processing for Perceptual Video Coding

  • Choi, Kwang Yeon;Song, Byung Cheol
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.5
    • /
    • pp.366-373
    • /
    • 2016
  • This paper proposes a pre-processing algorithm to improve the coding efficiency of perceptual video coding. First, an input image is decomposed into multiple sub-bands through linear sub-band decomposition. Then, the sub-bands that have low visual sensitivity are suppressed by assigning small gains to them. Experimental results show that if the proposed algorithm is adopted for pre-processing in a High Efficiency Video Coding (HEVC) encoder, it can provide significant bit-saving effects of approximately 12% in low delay mode and 9.4% in random access mode.

Optimal Sub-bands Decision for Robust Watermarking (강건한 워터마킹을 위한 최적 부대역 결정)

  • Kim, Yoon-Ho;Kim, Tae-Gon
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.1
    • /
    • pp.105-111
    • /
    • 2007
  • This paper is concerned with fuzzy inference-based optimal sub-bands decision scheme which is to be embedded the watermark. It concentrated not only on design of fuzzy inference algorithm but also on human visual parameters (HVP), such as contrast sensitivity, texture degree. In the first, such human visual parameters as contrast sensitivity, texture degree as well as statistical characteristics are involved to select the optimal coefficients region. Secondly, fuzzy if - then rule which can be able to adapt the wide variety of environments is developed. The performance of proposed approach is evaluated with respect to the imperceptibility and correctness of watermark. According to some experimental results, contrast sensitivity function is superior in smooth image. On the other hand, statistical characteristics provide good results in rough images.

  • PDF

Digital Watermarking using the suitable watermark strength and length (최적의 워터마크 강도와 길이를 이용한 디지털 워터마킹)

  • Lee, Young-Hee;Lee, Jung-Hee;Cha, Eui-Young
    • The Journal of Korean Association of Computer Education
    • /
    • v.9 no.5
    • /
    • pp.77-84
    • /
    • 2006
  • In this paper, we propose an adaptive image watermarking algorithm in DWT domain by using HVS(human Visual system) and SOM(Self-Organizing Map) among neural networks. HVS can be described in terms of two properties of HVS: brightness and texture sensitivity. The SOM is used to obtain the local characteristics of image, Therefore, the suitable strength and length of embedded watermark is determined by using HVS and SOM. The experimental results show that proposed method provides a suitable strength and length of watermark and has good perceptual invisibility and robustness for various attacks.

  • PDF

TFT-LCD Defect Enhancement Using Frequency Sensitivity of HVS (인간 시각시스템의 주파수 감도를 이용한 TFT-LCD 결함 강조)

  • Oh, Jong-Hwan;Park, Kil-Houm
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.5
    • /
    • pp.20-27
    • /
    • 2007
  • Generally, the TFT-LCD image signal have nonuniform brightness and are composed of largely varying background signal, noise signal and abruptly changing Mura signal within Mura region. In this paper, Mura region enhancing algorithms using the proposed modified-MTF, which describes how human-visual-system's sensitivity varies in frequency domain, is proposed. The validity of the proposed algorithm was demonstrated ideal 1-dimensional signal and also then it was also tested TFT-LCD image. By the experimental results, the proposed algorithm is very effective in TFT-LCD image Mura enhancement.

Comparing the effect of a desensitizing material and a self-etch adhesive on dentin sensitivity after periodontal surgery: a randomized clinical trial

  • Hajizadeh, Hila;Nemati-Karimooy, Atefeh;Majidinia, Sara;Moeintaghavi, Amir;Ghavamnasiri, Marjaneh
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.168-175
    • /
    • 2017
  • Objectives: This double-blind randomized placebo-controlled clinical trial evaluated the ability of a desensitizing agent and a self-etch adhesive on cervical dentin sensitivity (CDS) after periodontal surgery. Materials and Methods: Ninety hypersensitive teeth of 13 subjects were included in the study. After periodontal surgery, the teeth of each posterior sextant treated with one of the following materials: G1: Clearfil $S^3$ Bond (Kuraray Dental), G2: Gluma Desensitizer (Heraeus Kulzer), and G3: placebo (water). The sensitivity was assessed using evaporative stimuli before treatment (baseline, T0), 1 day after treatment (T1), after 1 week (T2), and 1 month (T3) according to visual analog scale (VAS). Results: Following the treatment, all the 3 groups showed significant reduction of CDS in T1 compared to T0. Reduction of CDS between T1 and T2 was observed only in G1 but there was no significant difference between T2 and T3 in this group. Although we observed a significant difference in T3 compared to T1 and T2 in G2 and G3, comparison of treatment groups in each assessment time showed a significant difference only in T3. According to paired comparison, this was due to the difference between G2 and G3. Conclusions: Dentin sensitivity following periodontal surgery will decrease spontaneously over time, but treating the sensitive teeth with Gluma Desensitizer and Clearfil $S^3$ Bond can have some benefits.

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.

Changes of Visual Acuity and Visual Function in the Elderly Generation and their Subjective Satisfaction by the Use of Tinted Ophthalmic Lenses (착색안경렌즈의 사용에 따른 노년층의 시력 및 시기능 변화와 자각적 만족도)

  • Ryu, Deok-Hyeon;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Purpose: The study was aimed to suggest the most effective color of the tinted lenses by evaluating the effect of the prescription with tinted lenses on the visual quality of the elderly at the age of the sixty or more. Methods: The visual acuity of fifty subjects at the age of sixty or more (17 males, 33 females with the averaged age of $71.0{\pm}6.3$) were corrected to have the visual acuity at a far distance of 0.5 or more using a trial lens frame, and non-tinted, brown-tinted, and gray-tinted lenses were randomly applied on the trial frame. The minimum legibility and minimum separability were measured at a far distance in the aspect of the visual acuity and calculated as LogMAR and then, the visual acuity was compared. The stereopsis and contrast sensitivity were also estimated at a near distance in the aspect of the visual function. The participants' preference for tinted lenses and their subjective symptoms of the visual perception and the movement were further surveyed. Results: The best minimum legibility and minimum separability was shown when wearing non-tinted lenses, and brown-tinted and gray-tinted lenses were in the next. The stereopsis and the contrast sensitivity at a near distance and the visual perception was the best when wearing brown-tinted lenses. It was surveyed that the subjective discomfort was the biggest when wearing gray-tinted lenses, and brown-tinted lenses were the best in the aspect of the subjective preference. Conclusions: As the result of this study, it was revealed that the visual acuity and visual function could be improved by the use of tinted ophthalmic lenses however, its change of visual acuity and visual function was not completely correlated with the subjective satisfaction. Therefore, the appropriate color of ophthalmic lenses should be selected in accordance with the individual visual perception and the main vision lifestyle in the elderly generation. From the present study, the use of non- or brown-tinted lens and brown- or gray-tinted lens can be recommended for distance work and near work, respectively, in the elderly generation under the illumination of about 1,000 lux.

Synergism Between Zinc and Taurine in the Visual Sensitivity of the Bullfrog's Eye

  • Kim, Hyun-Jung;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.7 no.3
    • /
    • pp.115-121
    • /
    • 2000
  • Although there are high concentrations of zinc and taurine in ocular tissue, their exact role and correlation in the visual process are not clear. The purpose of present study was to clarity this point using electroretinogram (ERG) recording and spectrophotometer measurements before and after zinc and taurine treatment in bullfrog's eye. The optimal zinc concentration used in this study was 10$^{-2}$ M ZnCl$_2$120 ${mu}ell$/12$m\ell$ ringer solution while the optimal turine concentration was 10$^{-2}$ M taurine 12${mu}ell$/12$m\ell$ ringer solution. For the effects of zinc and taurine on the retinal function, the changes of ERG parameters (especially threshold and b-wave) and absorption spectra were observed before and after treatment. It is noteworthy that high concentrations of zinc and taurine present in the retinal pigment epithelium and the retina. Our results indicate that dark-adapted ERG threshold became elevated and the peak amplitude of b-wave was increased with zinc and taurine treatment. Furthermore there are some synergism effects between zinc and taurine as a result of co-treatment. In spectral scan, absorbance increment due to zinc and taurine treatment was shown over the whole range of spectral range (300-750 nm) with some differences in absorbance increment depending on the case of treatment. As the results of above we believe that zinc and taurine, which are abundant in the retinal pigment epithelium and the retina particularly, may be essential factors for visual process, have some synergism with each other and be required to improve the visual sensitivity during visual adaptation.

  • PDF