• Title/Summary/Keyword: Visual sensitivity

Search Result 384, Processing Time 0.029 seconds

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color (분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.44-52
    • /
    • 2017
  • This paper is based on a study of the response characteristics of photoelectric type smoke detector chambers according to dust color. Due to an amendment to the Fire Safety Codes to automatic fire alarm systems and visual alarm device, the installation of indoor smoke detectors has become mandatory, but in Korea there is still insufficient research on the non-operation or false alarms that could arise in indoor environments by indoor dust and other environmental conditions etc. In light of this, for this study, research was conducted on the indoor adaptability of smoke detector under various colors of fiber dust that were judged to occur most frequently in among the common indoor dust, photoelectric smoke detector with the lattice-type smoke detection chamber that the smoke detector which is most popular in the country was used, and four colors of fiber dust (brown, white, gray and black) were used the test dusts for carrying out dust and sensitivity testing. Also, the voltage of the photocell part of the smoke chamber was measured, and the scattering phenomenon in the chamber was observed. The result of the testing showed that all four dust types were suitable for dust and sensitivity testing under conditions of pollution A. Yet, there were occasions, at pollution B or C, where the brown, white and gray dust would cause fail alarm during operation testing. And black dust was confirmed to cause non-operation during operation testing. In the case of brown and white dust, the voltage measurement result of the photocell part of the smoke chamber confirmed that the voltage increases as the pollution level increases, and in the case of gray and black dust, the voltage decreases.

Effect Cross-national Brand Personality on Preference and Revisiting in Fastfood Restaurant (한.중 대학생의 브랜드 개성이 선호도 및 재방문에 미치는 영향)

  • Lee, Sang-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.9
    • /
    • pp.403-410
    • /
    • 2009
  • This paper is to find out which factors affect preference and revisiting on brand personality according to cross-national college students in Korea and China, and to suggest distinguished strategies for attracting core customers continuously on each country and restaurants. The questionary hand out each 150, then used for data analysis 142 in Korean, 122 in China. The results come up with; First, It couldn't compared huge gap for McDonald and Burger King in sampling. Second, three variables (successful, harmony, and western) are highly recognized brand personality in Korean. They should build up powerful image to communicate 20's ages. For Chinese that ranked highly three variables (Darling, Friendly, and Sincere), they reinforced warm-hearted image with special character, providing promotion coupon, and various event. Third, because 2 factors(Sincere and Sensitivity) had significant in preference for Korean and Chinese. It should be formed non-producted parts which are visual decoration, atmosphere, uniform and music. Also, 'feminine' had meaningful for Chinese. Fourth, 'Sincere' was connected directly in revisiting for Korean and Chinese. Trust Is prior to customer and brand. Also, for Korean, 'sensitivity' had significant. Therefore, it should make exciting surrounding, and atmosphere.

Effects of GaAs (904 nm) Low Level Laser Therapy on Dentin Hypersensitivity (과민치아에 대한 904nm GaAs 반도체레이저의 효과)

  • Won, Tae-Hee;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.4
    • /
    • pp.215-224
    • /
    • 2011
  • The aim of the study was to investigate the effects of 904 nm GaAs laser irradiation for patients with hypersensitive teeth and to find the possibility of clinical use of this Low Level Laser Therapy (LLLT) for the control of hypersensitive teeth. Eleven patients visited Dept. of Oral Medicine, Dankook University participated in this study. Each patient contributed at least two or more contralateral pairs of hypersensitive teeth with exposed dentine at cervical surfaces. Total number of teeth used from subjects participated in this study was 50: 25 experimental and control teeth respectively. All participants were treated with 904 nm GaAs diode laser every week during 4 weeks. Tactile and cold (ice stick) tests were carried out before LLLT every week during 4 weeks and 1 week later after the last LLLT by measuring visual analogue scale (VAS) of patients and by measuring a score of electrical pulp tester (EPT) simultaneously. The VAS score in tactile test decreased significantly with time, but there was not statistically difference between those of groups. The score of EPT in the experimental group was significantly higher than that of control group, although there was no change with time. In cold test, there was significant difference between two groups and cold sensitivity of the experimental group significantly decreased with time after every LLL irradiation, compared with that of control group. Based on the results, it is suggested that the 904 nm GaAs laser irradiation could be positively used as an effective, reversible method in treating cervical dentine hypersensitivity.

PPL of Visual Media Affects Clothing Purchase of College Students (영상매체의 PPL이 의복 구매에 미치는 영향에 대하여)

  • Song, Jae-Wook;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.9 no.4
    • /
    • pp.331-339
    • /
    • 2006
  • PPL(Product Placement) of visual media can change the purchasing behavior of College students. This study aimed to investigate the differences in consumer's conception about PPL among college students and to analyze the relationship between the PPL conception ant fashion innovation/fashion sensitivity of students, resulting into their real purchasing behavior. We surveyed to about 189 college students living near Seoul, with questionnaire about PPL conception, purchase of PPL clothing, satisfaction on PPL clothing, fashion innovation, opinion about PPL, PPL apparel brand to recall, etc. According to dichotomy of college students by fashion innovation, as higher fashion innovative they were, they paid more attention on PPL clothing while watching TV or movie, and they also could recall more PPL apparel brands, and they purchased more PPL clothing. While the students with low fashion innovation had references from the opinion of friends or around people when purchasing their clothing, the students with high fashion innovation did from fashion magazine or PPL clothing. The students who thought that PPL was important and effective on clothing purchasing behavior, answered that their preference to PPL bran4, to the company, and to the product had increased positively, but not to the actor/actress.

  • PDF

DEVELOPMENT OF OPTICAL CARIES ACTIVITY TEST USING DENTAL CURING LIGHT (광중합기를 이용한 광학적 치아우식활성도 검사법)

  • Lee, Nan-Young;Kim, Mi-Ra;Oh, You-Hyang;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.671-679
    • /
    • 2004
  • The purpose of this study was to develop a practical caries activity test by fluorescence using laser, plasma light and halogen light. The subjects of study were 45 children of 7-8 years old Argon laser, plasma light and halogen light were irradiated to buccal or labial surface of all teeth. Fluorescence of initial carious lesion from teeth was observed through barrier filter and the number of teeth showing lesion was counted. Visual examination for the dDfFtT, mutans streptococci screening test and Lactobacilli colony counting were also done. Data analysis was accomplished by Axelsson's method. The result from the present study can be summarized as follows. 1. Laser, plasma light and halogen light could detect the initial carious lesions better than visual examination(p<0.05). 2. There was positive correlation between laser(r=0.42), plasma light(r=0.41), halogen light(r=0.39) and dBfFtT rate(p<0.01). 3. The specificity sensitivity and predictive value was showed highest value in laser, but was showed favorable value in plasma light and halogen light. In regard to above results, laser, plasma light and halogen light all considered to be reliable method for determining individual caries activity. And they were also considered to be practical method because it would be simple, inexpensive, and time saving method.

  • PDF

Detecting of Proximal Caries in Primary Molars using Pen-type QLF Device (펜-타입 QLF 장비의 임상적 유구치 인접면 우식 탐지 성능)

  • Cho, Hyejin;Kim, Hyuntae;Song, Ji-Soo;Shin, Teo Jeon;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.405-413
    • /
    • 2021
  • The purpose of this in vivo study was to assess the clinical screening performance of a quantitative light-induced fluorescence (QLF) device in detecting proximal caries in primary molars. Fluorescence loss, red autofluorescence and a simplified QLF score for proximal caries (QS-proximal) were evaluated for their validity in detecting proximal caries in primary molars compared to bitewing radiography. Three hundred and forty-four primary molar surfaces were included in the study. Carious lesions were scored according to lesion severity assessed by visual-tactile and radiographic examinations. The QLF images were analyzed for two quantitative parameters, fluorescence loss and red autofluorescence, as well as for QS-proximal. For both quantitative parameters and QS-proximal, the sensitivity, specificity and area under receiver operating curve (AUROC) were calculated as a function of the radiographic scoring index at enamel and dentin caries levels. Both quantitative parameters showed fair AUROC values for detecting dentine level caries (△F = 0.794, △R = 0.750). QS-proximal showed higher AUROC values (0.757 - 0.769) than that of visual-tactile scores (0.653) in detecting dentine level caries. The QLF device showed fair screening performance in detecting proximal caries in primary molars compared to bitewing radiography.

99mTc-3PRGD2 SPECT/CT Imaging for Diagnosing Lymph Node Metastasis of Primary Malignant Lung Tumors

  • Liming Xiao;Shupeng Yu;Weina Xu;Yishan Sun;Jun Xin
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1142-1150
    • /
    • 2023
  • Objective: To evaluate 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid (99mTc-3PRGD2) single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging for diagnosing lymph node metastasis of primary malignant lung neoplasms. Materials and Methods: We prospectively enrolled 26 patients with primary malignant lung tumors who underwent 99mTc-3PRGD2 SPECT/CT and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT imaging. Both imaging methods were analyzed in qualitative (visual dichotomous and 5-point grades for lymph nodes and lung tumors, respectively) and semiquantitative (maximum tissue-to-background radioactive count) manners for the lymph nodes and lung tumors. The performance of the differentiation of lymph nodes with and without metastasis was determined at the per-lymph node station and per-patient levels using histopathological results as the reference standard. Results: Total 42 stations had metastatic lymph nodes and 136 stations had benign lymph nodes. The differences between metastatic and benign lymph nodes in the visual qualitative and semiquantitative analyses of 99mTc-3PRGD2 SPECT/CT and 18F-FDG PET/CT were statistically significant (all P < 0.001). The area under the receiver operating characteristic curve (AUC) in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT was 0.908 (95% confidence interval [CI], 0.851-0.966), and the sensitivity, specificity, positive predictive value, and negative predictive value were 0.86 (36/42), 0.88 (120/136), 0.69 (36/52), and 0.95 (120/126), respectively. Among the 26 patients (including two patients each with two lung tumors), 15 had pathologically confirmed lymph node metastasis. The difference between primary lung lesions in patients with and without lymph node metastasis was statistically significant only in the semi-quantitative analysis of 99mTc-3PRGD2 SPECT/CT (P = 0.007), with an AUC of 0.807 (95% CI, 0.641-0.974). Conclusion: 99mTc-3PRGD2 SPECT/CT imaging may notably perform in the direct diagnosis of lymph node metastasis of primary malignant lung tumors and indirectly predict the presence of lymph node metastasis through uptake in the primary lesions.

The Usefulness of 18F-FDG PET to Differentiate Subtypes of Dementia: The Systematic Review and Meta-Analysis

  • Seunghee Na;Dong Woo Kang;Geon Ha Kim;Ko Woon Kim;Yeshin Kim;Hee-Jin Kim;Kee Hyung Park;Young Ho Park;Gihwan Byeon;Jeewon Suh;Joon Hyun Shin;YongSoo Shim;YoungSoon Yang;Yoo Hyun Um;Seong-il Oh;Sheng-Min Wang;Bora Yoon;Hai-Jeon Yoon;Sun Min Lee;Juyoun Lee;Jin San Lee;Hak Young Rhee;Jae-Sung Lim;Young Hee Jung;Juhee Chin;Yun Jeong Hong;Hyemin Jang;Hongyoon Choi;Miyoung Choi;Jae-Won Jang;Korean Dementia Association
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.54-66
    • /
    • 2024
  • Background and Purpose: Dementia subtypes, including Alzheimer's dementia (AD), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD), pose diagnostic challenges. This review examines the effectiveness of 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) in differentiating these subtypes for precise treatment and management. Methods: A systematic review following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines was conducted using databases like PubMed and Embase to identify studies on the diagnostic utility of 18F-FDG PET in dementia. The search included studies up to November 16, 2022, focusing on peer-reviewed journals and applying the goldstandard clinical diagnosis for dementia subtypes. Results: From 12,815 articles, 14 were selected for final analysis. For AD versus FTD, the sensitivity was 0.96 (95% confidence interval [CI], 0.88-0.98) and specificity was 0.84 (95% CI, 0.70-0.92). In the case of AD versus DLB, 18F-FDG PET showed a sensitivity of 0.93 (95% CI 0.88-0.98) and specificity of 0.92 (95% CI, 0.70-0.92). Lastly, when differentiating AD from non-AD dementias, the sensitivity was 0.86 (95% CI, 0.80-0.91) and the specificity was 0.88 (95% CI, 0.80-0.91). The studies mostly used case-control designs with visual and quantitative assessments. Conclusions: 18F-FDG PET exhibits high sensitivity and specificity in differentiating dementia subtypes, particularly AD, FTD, and DLB. This method, while not a standalone diagnostic tool, significantly enhances diagnostic accuracy in uncertain cases, complementing clinical assessments and structural imaging.

Suitability Analysis on Land Use for Eco-City using GIS (GIS를 활용한 생태도시의 토지적합성 분석)

  • Han, Gab-Soo;Jo, Hyun-Kil;Lee, Chang-Hwan;An, Tae-Won
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.2
    • /
    • pp.111-119
    • /
    • 2009
  • The purpose of this study is to decide the suitability of the land use on eco-city by analysing ecological elements using GIS. Selected ecological elements for suitability analysis were altitude, slope, watershed, biotope, soil productivity, visual sensitivity, vegetation, and green connection. The category of each element was classified into 5 grades, and was given weight according to each element. The maximum value of each element was extracted from overlay analysis process. The result of analysis was classified into 5 grade finally. As a result, land use was proposed to be development, conservation, and preservation area.

  • PDF

Fashion Style and Sensibility Fusion Effect of Fashion Icons in the 21th Century (21세기 패션아이콘의 패션 스타일과 감성적 융합작용)

  • Park, Song-Ae
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.15 no.3
    • /
    • pp.109-118
    • /
    • 2013
  • Fashion icons of 21st century are not only the fashion leaders that show fashion trend but also the typical fashion signs or symbols that show visually changes in sensibility trends. The purpose of this study was to analyze the framework of 21st century fashion by the public to recognize through these changes. In this study, the background of the occurrence of various 21st century fashion icons and their characteristics were investigated and the changes of revealed features and symbolic meanings were examined compared with them of 20th century. The 24 celebrities which have been called as the bests of fashion icons since year 2000 were selected by searching the most popular search engines such as daum, yahoo and google, and 13 of them were picked as the highest in preference and awareness by surveying 50 students majoring in fashion. And then their fashion styles, backgrounds, and influence on the public fashion were studied. As a result, the 21st century fashion icons reflecting the cultural characteristics such as convergence and exaggeration and the sensitivities of fusion, collaboration, hybrid sensibility in art were powerful enough to create innovative styles destroying the era and the standard. Their styles have constantly created new looks. The exposed new individual sensitivities on media-fusion of two or more sensibility and coordination techniques without being tied to the existing anchorage system-were as influential as high fashion and leaded the imitation and reproduction by dazzling the public. As the media become more powerful, the influence of fashion icons interacted more closely with the public and has been evolved through the sensitivity of the reversal, cultural, economic, visual, or temporal fusions. To sum up, it is shown that the outstanding fashion styles suggested by the leading fashion designers have approach to the public more closely by the fashion icons.

  • PDF