• Title/Summary/Keyword: Visual Reconstruction

Search Result 218, Processing Time 0.022 seconds

Use of platelet-rich plasma and modified nanofat grafting in infected ulcers: Technical refinements to improve regenerative and antimicrobial potential

  • Segreto, Francesco;Marangi, Giovanni Francesco;Nobile, Carolina;Alessandri-Bonetti, Mario;Gregorj, Chiara;Cerbone, Vincenzo;Gratteri, Marco;Caldaria, Erika;Tirindelli, Maria Cristina;Persichetti, Paolo
    • Archives of Plastic Surgery
    • /
    • v.47 no.3
    • /
    • pp.217-222
    • /
    • 2020
  • Background Surgical reconstruction of chronic wounds is often infeasible due to infection, comorbidities, or poor viability of local tissues. The aim of this study was to describe the authors' technique for improving the regenerative and antimicrobial potential of a combination of modified nanofat and platelet-rich plasma (PRP) in nonhealing infected wounds. Methods Fourteen patients met the inclusion criteria. Fat tissue was harvested from the lower abdomen following infiltration of a solution of 1,000 mL of NaCl solution, 225 mg of ropivacaine, and 1 mg of epinephrine. Aspiration was performed using a 3-mm cannula with 1-mm holes. The obtained solution was decanted and mechanically emulsified, but was not filtered. Non-activated leukocyte-rich PRP (naLR-PRP) was added to the solution before injection. Patients underwent three sessions of injection of 8-mL naLR-PRP performed at 2-week intervals. Results Thirteen of 14 patients completed the follow-up. Complete healing was achieved in seven patients (53.8%). Four patients (30.8%) showed improvement, with a mean ulcer width reduction of 57.5%±13.8%. Clinical improvements in perilesional skin quality were reported in all patients, with reduced erythema, increased thickness, and increased pliability. An overall wound depth reduction of 76.6%±40.8% was found. Pain was fully alleviated in all patients who underwent re-epithelization. A mean pain reduction of 42%±33.3% (as indicated by visual analog scale score) was found in non-re-epithelized patients at a 3-month follow-up. Conclusions The discussed technique facilitated improvement of both the regenerative and the antimicrobial potential of fat grafting. It proved effective in surgically-untreatable infected chronic wounds unresponsive to conventional therapies.

An Efficient Walkthrough from Two Images using Spidery Mesh Interface and View Morphing (Spidery 매쉬 인터페이스와 뷰 모핑을 이용한 두 이미지로부터의 효율적인 3차원 애니메이션)

  • Cho, Hang-Shin;Kim, Chang-Hun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.2
    • /
    • pp.132-140
    • /
    • 2001
  • This paper proposes an efficient walktlu-ough animation from two images of the same scene. To make animation easily and fast, Tour Into the Picture(TIP) enables walkthrough animation from single image but lacks the reality of its foreground object when the viewpoint moves from side to side, and view morphing uses only 2D transition between two images but restricts its camera path on the line between two views. By combining advantages of these two image-based techniques, this paper suggests a new virtual navigation technique which enable natural scene transformation when the viewpoint changes in the side-to-side direction as well as in the depth direction. In our method, view morphing is employed only in foreground objects , and background scene which is perceived carelessly is mapped into cube-like 3D model as in TIP, so as to save laborious 3D reconstruction costs and improve visual realism simultaneously. To do this, we newly define a camera transformation between two images from the relationship of the spidery mesh transformation and its corresponding 3D view change. The result animation shows that our method creates a realistic 3D virtual navigation using a simple interface.

  • PDF

A Research on the Scenography of the Musical 『All Shook Up』 - Focusing on the Design Construction Process and Performance Application Cases - (뮤지컬 『All Shook Up』의 연출적 시노그래피 연구 - 디자인 구축 과정과 공연 적용 사례를 중심으로 -)

  • Park, Geun-Hyung;Cho, Joon-Hui
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.8
    • /
    • pp.175-187
    • /
    • 2020
  • The purpose of this study is to discuss the elements and meanings of the performative scenography which has been revealed through the new directorial interpretation and deconstruction process of the musical 『All Shook Up』. The performative scenography characteristics after postmodernism aim to create individual active perceptions and various social meanings through audience's voluntary and particular emergence. To this end, the theoretical foundation of scenography was examined by periods in advance. Based on this, I attempted to establish performative scenography for synthesized scenic and media design through the reconstruction process for the 『All Shook Up Travelers』. As a result, I set up visual narrative based world of 『All Shook Up Travelers』 which was produced by text-based intense images for a direct medium in order to expand actors' inner narrative and established unique performative scenography of its own: 1. enhancing the adapted one's narratives for the actors' and audience's co-existence and detachment, 2. delivering its own independent meanings which have double meanings, 3. encouraging audience's critical and active perception experiences through collage and montage of media.

Biometry of width between labial transitional line angles in anterior teeth: an observational study

  • Wen, Chao;Ye, Hongqiang;Chen, Hu;Zhou, Yongsheng;Huang, Mingming;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • PURPOSE. The maximum width between the mesial and distal labial transitional line angles, described as "esthetic width" herein, could significantly influence the visual perception of the teeth and smile. This study aimed to conduct biometric research on esthetic width and to explore whether regular distribution exists in the esthetic width of human teeth. MATERIALS AND METHODS. A total of 4,264 maxillary and mandibular anterior teeth were measured using the Geomagic studio software program. The proportions of maxillary to mandibular homonymous teeth and proportions between the adjacent teeth were calculated. Bilateral symmetry and the correlation between the esthetic and mesiodistal widths were both accounted for during the measurement procedures. RESULTS. The mean esthetic widths were 6.773 ± 0.518 mm and 4.329 ± 0.331 mm for maxillary and mandibular central incisors, respectively, 5.451 ± 0.487 mm and 5.008 ± 0.351 mm for maxillary and mandibular lateral incisors, respectively, and 3.340 ± 0.353 mm and 5.958 ± 0.415 mm for maxillary and mandibular canines, respectively. Except for the mandibular canines, no significant difference in esthetic width was found among homonymous teeth from the same jaw. A high linear correlation was found between the esthetic and mesiodistal widths of the same tooth, except for the maxillary canines. Esthetic width proportions among different tooth categories showed some regular patterns, which were similar to those of the mesiodistal width. CONCLUSION. Esthetic width is regularly distributed among the teeth in the Chinese population. This could provide an important reference for anterior dental restorations and dimension recovery in esthetic reconstruction of anterior teeth.

Subjective and Objective Assessment of Monoenergetic and Polyenergetic Images Acquired by Dual-Energy CT in Breast Cancer

  • Xiaoxia Wang;Daihong Liu;Shixi Jiang;Xiangfei Zeng;Lan Li;Tao Yu;Jiuquan Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.502-512
    • /
    • 2021
  • Objective: To objectively and subjectively assess and compare the characteristics of monoenergetic images [MEI (+)] and polyenergetic images (PEI) acquired by dual-energy CT (DECT) of patients with breast cancer. Materials and Methods: This retrospective study evaluated the images and data of 42 patients with breast cancer who had undergone dual-phase contrast-enhanced DECT from June to September 2019. One standard PEI, five MEI (+) in 10-kiloelectron volt (keV) intervals (range, 40-80 keV), iodine density (ID) maps, iodine overlay images, and Z effective (Zeff) maps were reconstructed. The contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) were calculated. Multiple quantitative parameters of the malignant breast lesions were compared between the arterial and the venous phase images. Two readers independently assessed lesion conspicuity and performed a morphology analysis. Results: Low keV MEI (+) at 40-50 keV showed increased CNR and SNRbreast lesion compared with PEI, especially in the venous phase ([CNR: 40 keV, 20.10; 50 keV, 14.45; vs. PEI, 7.27; p < 0.001], [SNRbreast lesion: 40 keV, 21.01; 50 keV, 16.28; vs. PEI, 10.77; p < 0.001]). Multiple quantitative DECT parameters of malignant breast lesions were higher in the venous phase images than in the arterial phase images (p < 0.001). MEI (+) at 40 keV, ID, and Zeff reconstructions yielded the highest Likert scores for lesion conspicuity. The conspicuity of the mass margin and the visual enhancement were significantly better in 40-keV MEI (+) than in the PEI (p = 0.022, p = 0.033, respectively). Conclusion: Compared with PEI, MEI (+) reconstructions at low keV in the venous phase acquired by DECT improved the objective and subjective assessment of lesion conspicuity in patients with malignant breast lesions. MEI (+) reconstruction acquired by DECT may be helpful for the preoperative evaluation of breast cancer.

The Usefulness of F-18-FDG PET and The Effect of Scan Protocol in Diagnosis of Intraocular Tumors (안구 내 종양의 진단에 있어서 F-18-FDG PET의 유용성과 검사 방법의 영향)

  • Lee, Jae-Soung;Yang, Won-Il;Kim, Byoung-Il;Choi, Chang-Woon;Lim, Sang-Moo;Lee, Tae-Won;Sin, Min-Kyeung;Hong, Soung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.5
    • /
    • pp.439-451
    • /
    • 1999
  • Purpose : It is important to differentiate malignant from benign lesions of intraocular masses in choosing therapeutic plan. Biopsy of intraocular tumor is not recommended due to the risk of visual damage. We evaluated the usefulness of F-18-FDG PET imaging in diagnosing intraocular neoplasms. Materials and Methods: F-18-FDG PET scan was performed in 13 patients (15 lesions) suspected to have malignant intraocular tumors. There were 3 benign lesions (retinal detachment, choroidal effusion and hemorrhage) and 10 patients with 12 malignant lesions (3 melanomas, 7 retinoblastomas and 2 metastatic cancers). Regional eye images ($256{\times}256$ and $128{\times}128$ matrices) were obtained with or without attenuation correction. Whole body scan was also performed in eight patients (3 benign and 6 malignant lesions). Results: All malignant lesions were visualized while all benign lesions were not visualized. The mean peak standardized uptake value (SUV) of malignant lesions was $2.64{\pm}0.57g/ml$. There was no correlations between peak SUV and tumor volume. Two large malignant lesions ($> 1000 mm^3$) showed hot uptake on whole body scan. But two medium-sized lesions ($100-1000mm^3$) looked faint and two small ($<100mm^3$) lesions were not visualized. The images reconstructed with $256{\times}256$ matrix showed lesions more clearly than those with $128{\times}128$ matrix Conclusion: F-18-FDG PET scan is highly sensitivity in detecting malignant intraocular tumor For the evaluation of small-sized intraocular lesions, whole body scan is not appropriate because of low sensitivity. A regional scan with sufficient acquisition time is recommended for that purpose. Image reconstruction in matrix size of $256{\times}256$ produced clearer images than the ones in $128{\times}128$, but it does not affect the diagnostic sensitivity.

  • PDF

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

A Study on the Quality Improvement of Brain Perfusion SPECT Image (뇌혈류 단일광자방출단층촬영 영상 품질 향상에 대한 연구)

  • Kil, Sang-Hyeong;Lim, Yung-Hyun;Park, Gwang-Yeol;Cho, Seong-Mook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2019
  • Purpose Tc-99m HMPAO is widely used radiopharmaceutical for brain perfusion SPECT. Tc-99m HMPAO is chemically unstable and is liable to show deterioration of labeling efficiency due to high incidence of secondary Tc-99m HMPAO complex, free pertechnetate and reduced-hydrolyzed Tc-99m. In this study, we investigated whether sialogogues administration could reduce the impurities of Tc-99m HMPAO. Materials and Methods In thirty subjects(20 male and 10 female, age range 19~89 years, mean age $60.7{\pm}14.5years$), brain perfusion SPECT were performed at basal and citric acid stimulation states consecutively after injection of 555 MBq of Tc-99m HMPAO. In the salivary glands, the uptake coefficient was calculated using Siemens processing program. Statistical comparison between before and after the citric acid stimulation performed paired t-test. P value less than 0.05 was regarded as statistically significant. Results Salivary glands uptake was $12900{\pm}3101$ counts in basal and $10677{\pm}2742$ counts in citric acid stimulation states. Unnecessary impurities in the body is much decreased after citric acid administration(t=10.78, P<0.05). The image quality was much improved after administration of citric acid and the regional cerebral perfusion was clearly from demarcated the background. Conclusion The impurity is distributed throughout the body particularly in the salivary glands and nasal mucosa when Tc-99m HMPAO brain perfusion SPECT is performed. If this impurities is not removed, the quality of the image may deteriorate, resulting in errors in visual evaluation. The use of sialogogues could be helpful for decreasing unnecessary impurities in the body.