• 제목/요약/키워드: Virtual point detector

검색결과 8건 처리시간 0.029초

교차 참조 점을 이용한 정지영상의 워터마크 삽입기법 (A Watermark Embedding Technique for Still Images Using Cross-Reference Points)

  • 이항찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권4호
    • /
    • pp.165-172
    • /
    • 2006
  • In this paper we present a technique for detecting cross-reference points that allows improving watermark detect-ability. In general, Harris detector is commonly used for finding salient points. Harris detector is a kind of combined corner and edge detector which is based on neighboring image data distribution, therefore it has some limitation to find accurate salient points after watermark embedding or any kinds of digital attacks. The new method proposed in this paper used not data distribution but geometrical structure of a normalized image in order to avoid pointing error caused by the distortion of image data. After normalization, we constructed pre-specified number of virtual lines from top to bottom and left to right, and several of cross points were selected by a random key. These selected points specify almost same positions with the accuracy more than that of Harris detector after digital attacks. These points were arranged by a random key, and blocks centered in these points were formed. A reference watermark is formed by a block and embedded in the next block. Because same alteration is applied to the watermark generated and embedded blocks. the detect-ability of watermark is improved even after digital attacks.

가변형 쐐기필터의 선량분포에 관한 특성 (Characteristics of dose distribution for virtual wedge)

  • 김부길;김진기
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.125-131
    • /
    • 2001
  • 방사선을 이용한 치료기인 의료용 선형가속기에 부착하여 선량분포 조절에 사용하는 가변형 쐐기필터(virtual wedge)의 선량분포 특성를 분석하고 쐐기각의 자료를 비교하여 가변형 쐐기필터 적용에서 오는 선량분포의 변화를 알아보고자 하였다. 기준전리함인 단일채널 PTW-UNIDOS과 3차원 선량계측시스템인 RFA-7 그리고 실험적으로 구성된 다중채널 검출기의 특성실험을 통하여 선량분포도 및 쐐기각을 구하고 이를 이용하여 실험적 검출시스템의 측정인자를 보정하였다. 가변형 쐐기필터의 쐐기각은 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ 에서 고정형 쐐기필터에 비교하여 1$^{\circ}$ 이내로 안정하였고, 60$^{\circ}$ 경우는 6 MV에서 1.2$^{\circ}$, 10WV 에서 2.2$^{\circ}$ 의 변화를 보였다. 측정에너지 영역 6, 10 MV 의료용 광자선을 적용하여 선량백분율과 빔평탄도 측정결과 검출기의 신뢰도가 평균 $\pm$2.1 % 이내였다. 고정형 쐐기필터를 이용한 쐐기각 변화율방법 적용시 방사선치료 과정에서 나타나는 선량오차 및 정상조직의 피폭을 줄이고 장비의 과도한 부하를 감소시키며 가변형 쐐기필터의 다양한 치료방법의 적용을 모색할 수 있었다. 가변형 쐐기필터 이용과 측정된 선량분포의 특성 분석으로 기존 고정형 쐐기필터 이용방법 및 기능을 보완하였고 실험적으로 구성된 계측시스템 측정장비의 대체방법 보정으로 가변형 쐐기필터의 다양한 치료방법적용과 보조물 사용에 따른 정확성과 효율을 높이는데 유용하리라 사료된다.

  • PDF

Linearization Method Using Variable Capacitance in Inter-Stage Matching Networks for CMOS Power Amplifier

  • Yoon, Jaehyuk;Park, Changkun
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.454-460
    • /
    • 2019
  • In this paper, a watt-level 2.4-GHz RFCMOS linear power amplifier (PA) with pre-distortion method using variable capacitance with respect to input power is demonstrated. The proposed structure is composed of a power detector and a MOS capacitor to improve the linearity of the PA. The pre-distortion based linearizer is embedded in the two-stage PA to compensate for the gain compression in the amplifier stages, it also improves the output P1dB by approximately 1 dB. The simulation results demonstrate a 1-dB gain compression power of 30.81 dBm at 2.4-GHz, and PAE is 29.24 % at the output P1dB point.

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

  • Lee, Jun;Kim, Younghak;Bolotnikov, Aleksey;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4080-4092
    • /
    • 2021
  • In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm3. The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80%), while those evaluated using the minimum squared difference method (55-59%) and Three Compton method (45-55%) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

가상 텍스쳐 영상과 실촬영 영상간 매칭을 위한 특징점 기반 알고리즘 성능 비교 연구 (Study of Feature Based Algorithm Performance Comparison for Image Matching between Virtual Texture Image and Real Image)

  • 이유진;이수암
    • 대한원격탐사학회지
    • /
    • 제38권6_1호
    • /
    • pp.1057-1068
    • /
    • 2022
  • 본 논문은 모바일 기반의 실시간 영상 측위 기술 개발을 목표로 사용자가 촬영한 사진과 가상의 텍스쳐 영상 간의 매칭 가능성 확인 연구로 특징점 기반의 매칭 알고리즘의 조합 성능을 비교했다. 특징점 기반의 매칭 알고리즘은 특징점(feature)을 추출하는 과정과 추출된 특징점을 설명하는 서술자(descriptor)를 계산하는 과정, 최종적으로 서로 다른 영상에서 추출된 서술자를 매칭하고, 잘못 매칭된 특징점을 제거하는 과정으로 이루어진다. 이때 매칭 알고리즘 조합을 위해, 특징점을 추출하는 과정과 서술자를 계산하는 과정을 각각 같거나 다르게 조합하여 매칭 성능을 비교하였다. 가상 실내 텍스쳐 영상을 위해 V-World 3D 데스크탑을 활용하였다. 현재 V-World 3D 데스크톱에서는 수직·수평적 돌출부 및 함몰부와 같은 디테일이 보강되었다. 또한, 실제 영상 텍스쳐가 입혀진 레벨로 구축되어 있어, 이를 활용하여 가상 실내 텍스쳐 데이터를 기준영상으로 구성하고, 동일한 위치에서 직접 촬영하여 실험 데이터셋을 구성하였다. 데이터셋 구축 후, 매칭 알고리즘들로 매칭 성공률과 처리 시간을 측정하였고, 이를 바탕으로 매칭 성능 향상을 위해 매칭 알고리즘 조합을 결정하였다. 본 연구에서는 매칭 기법마다 가진 특장점을 기반으로 매칭 알고리즘을 조합하여 구축한 데이터셋에 적용해 적용 가능성을 확인하였고, 추가적으로 회전요소가 고려되었을 때의 성능 비교도 함께 수행하였다. 연구 결과, Scale Invariant Feature Transform (SIFT)의 feature와 descriptor 조합이 가장 매칭 성공률이 좋았지만 처리 소요 시간이 가장 큰 것을 확인할 수 있었고, Features from Accelerated Segment Test (FAST)의 feature와 Oriented FAST and Rotated BRIEF (ORB)의 descriptor 조합의 경우, SIFT-SIFT 조합과 유사한 매칭 성공률을 가지면서 처리 소요 시간도 우수하였다. 나아가, FAST-ORB의 경우, 10°의 회전이 데이터셋에 적용되었을 때에도 매칭 성능이 우세함을 확인하였다. 따라서 종합적으로 가상 텍스쳐 영상과 실영상간 매칭을 위해서 FAST-ORB 조합의 매칭 알고리즘이 적합한 것을 확인할 수 있었다.

초점 초음파 측정기로 측정한 광음향 신호의 광 흡수계수에 대한 비선형성 (Photoacoustic Nonlinearity to Absorption Coefficients in Photoacoustic Imaging with Focused Ultrasound Transducers)

  • 강동열
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.158-165
    • /
    • 2017
  • 광 흡수체로부터 측정되는 광음향 신호의 크기가 광 흡수계수 값의 증가에 따라 증가하다가 포화되는 광음향 비선형성에 대한 기존의 분석에서는 초음파 측정기의 물리적 형태를 고려하지 않았다. 이 논문에서는 초음파 측정기의 구면 초점 형태가 광음향 비선형성에 미치는 영향을 분석하였다. 구면 초점 초음파 측정기의 공간 필터링에 의한 광음향 공명 현상을 고려하고 기존의 광음향 비선형성에 대한 연구 방법을 보완하여 구면 초점 초음파 측정기로 측정한 광음향 신호에 대한 해석식을 이론적으로 유도하였다. 이 해석식에 의한 결과는 광음향 신호가 특정한 광 흡수계수 값에서 최대값을 나타내고 최대값 이후로는 광 흡수계수 값의 증가에 따라 오히려 감소함을 보였다. 주파수 영역에서 구면 초점 초음파 측정기에 의해 측정된 광음향 신호의 공명 스펙트럼과 초음파 측정기의 주파수 전달 함수를 비교하여 이 기존의 통념과는 다른 특징을 보이는 광음향 비선형성을 이해하였다. 또한, 이 주파수 영역에서의 물리적 해석으로 인해 광음향을 발생시키는 광 흡수체 내부의 광 조도 형태도 광음향 비선형성에 영향을 미친다는 것을 알 수 있었다.

붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구 (Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy)

  • 정주영;윤도군;한성민;장홍석;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제25권3호
    • /
    • pp.151-156
    • /
    • 2014
  • 본 연구의 목적은 붕소 중성자 포획 치료 시 집적된 붕소 영역에서 중성자 선속의 변화와 그에 따른 방출된 즉발 감마선의 검출 시뮬레이션을 통하여 치료 영역에 대한 영상화의 가능성을 확인하고자 함이다. 전산 모사를 통하여 (1) 붕소 유무에 따른 중성자의 영향, (2) 내부와 외부에서의 즉발 감마선량 검출, (3) 즉발 감마선에 대한 에너지 스펙트럼 검출을 수행하였다. 모든 전산 모사는 Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA)를 이용하여 가상의 물 팬텀과 열중성자(thermal neutron) 소스, 붕소 영역을 지정하였다. 열중성자의 에너지는 1 eV 이하의 에너지였으며 선속은 2,000,000 n/sec.로 설정하였다. 이 때, 발생된 즉발 감마선의 검출은 물 팬텀과 수직 방향으로 위치시키고 납으로 둘러싸인 lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) 섬광체 검출기를 이용하였다. 붕소가 존재하는 영역인 5 cm 깊이에서의 28 분할로서 대략 0.18 cm의 bin을 도출하여 붕소 영역의 얕은 깊이에서부터 급격하게 저하되는 것을 확인하였다. 또한 붕소 영역이 시작되는 지점인 9 cm 깊이에서 감마선의 피크 레벨을 확인하였다. 그리고 478 keV 지점에서 정확한 즉발 감마선 피크가 관찰되는 것을 확인하였다. 478 keV의 즉발 감마선 피크는 41 keV의 반치폭으로 에너지 분해능 값은 8.5%로 측정되었다. 결론적으로 붕소 중성자 포획 치료 시 발생되는 즉발 감마선의 계측으로 치료가 행해지는 부위를 감마 카메라 또는 단일 광자 방출 단층 촬영 기기에서 영상화할 수 있는 가능성을 확인하였다.