• Title/Summary/Keyword: Virtual Movement

Search Result 398, Processing Time 0.026 seconds

Active Spinning Training System using Complex Physiological Signals (복합 생체신호를 이용한 능동형 스피닝 트레이닝 시스템)

  • Kim, Cheol-Min;Kang, Gyeong-Heon;Kim, Eun-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.591-600
    • /
    • 2015
  • Recently high interest in health and fitness has led to vibrant researches for the active fitness system to learn and enjoy the exercise program for oneself. In this paper, we design and implement the active spinning training system which enables user to have self-learning and experience of customized spinning training program by the biometric and movement information acquired from user's physiological signals. The proposed system provides the appropriate difficulty of spinning program which reflects the concordance rate of spinning dance gestures and the amount of exercising by analyzing the physical status of participant from his brain and pulse waves and recognizing the skeletal movement in real time. For the higher exercise effect, the system offers a virtual personal trainer to show the correct poses and controls the level of difficulty depending on the concordance rate of participant's motions. The experiment with various participants through the proposed system shows that it is able to help users in getting the available exercise effect in comparatively short time.

Frame Morphing Technique for the Expression of Fish Growth Process (어류 성장과정 표현을 위한 프레임 모핑 기법)

  • Lee, HyeMi;Ryu, NamHoon;Lee, SangJin;Oh, KyeongSug;Kim, EungKon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.759-764
    • /
    • 2009
  • With its rapid growth, the digital contents-related industry is drawing attention as an industry generating a high value added. Specifically, the 3D morphing technology often used in the appearance or movement of each object comprising contents makes it possible to compose various contents by inferring the appearance and movement of the object. For a realistic swimming appearance of fish by using fish that swim in the water, this paper proposes a technique that applies the same speed concept as a physical pendulum to a swimming cycle and applies a frame morphing technique that is able to express the growth process from fry to adult fish. This article is capable of realistically reviving the fish growth process, and can through magnified applying can be applied to in 3D fishes encyclopedias or virtual underwater expressions etc. in the viewpoint which is oceanography.

  • PDF

Analysis on the Kinematics and Dynamics of Human Arm Movement Toward Upper Limb Exoskeleton Robot Control - Part 2: Combination of Kinematic and Dynamic Constraints (상지 외골격 로봇 제어를 위한 인체 팔 동작의 기구학 및 동역학적 분석 - 파트 2: 제한조건의 선형 결합)

  • Kim, Hyunchul;Lee, Choon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.875-881
    • /
    • 2014
  • The redundancy resolution of the seven DOF (Degree of Freedom) upper limb exoskeleton is key to the synchronous motion between a robot and a human user. According to the seven DOF human arm model, positioning and orientating the wrist can be completed by multiple arm configurations that results in the non-unique solution to the inverse kinematics. This paper presents analysis on the kinematic and dynamic aspect of the human arm movement and its effect on the redundancy resolution of the seven DOF human arm model. The redundancy of the arm is expressed mathematically by defining the swivel angle. The final form of swivel angle can be represented as a linear combination of two different swivel angles achieved by optimizing two cost functions based on kinematic and dynamic criteria. The kinematic criterion is to maximize the projection of the longest principal axis of the manipulability ellipsoid of the human arm on the vector connecting the wrist and the virtual target on the head region. The dynamic criterion is to minimize the mechanical work done in the joint space for each of two consecutive points along the task space trajectory. The contribution of each criterion on the redundancy was verified by the post processing of experimental data collected with a motion capture system. Results indicate that the bimodal redundancy resolution approach improved the accuracy of the predicted swivel angle. Statistical testing of the dynamic constraint contribution shows that under moderate speeds and no load, the dynamic component of the human arm is not dominant, and it is enough to resolve the redundancy without dynamic constraint for the realtime application.

Analysis on Kinematics and Dynamics of Human Arm Movement Toward Upper Limb Exoskeleton Robot Control Part 1: System Model and Kinematic Constraint (상지 외골격 로봇 제어를 위한 인체 팔 동작의 기구학 및 동역학적 분석 - 파트 1: 시스템 모델 및 기구학적 제한)

  • Kim, Hyunchul;Lee, Choon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.12
    • /
    • pp.1106-1114
    • /
    • 2012
  • To achieve synchronized motion between a wearable robot and a human user, the redundancy must be resolved in the same manner by both systems. According to the seven DOF (Degrees of Freedom) human arm model composed of the shoulder, elbow, and wrist joints, positioning and orientating the wrist in space is a task requiring only six DOFs. Due to this redundancy, a given task can be completed by multiple arm configurations, and thus there exists no unique mathematical solution to the inverse kinematics. This paper presents analysis on the kinematic and dynamic aspect of the human arm movement and their effect on the redundancy resolution of the human arm based on a seven DOF manipulator model. The redundancy of the arm is expressed mathematically by defining the swivel angle. The final form of swivel angle can be represented as a linear combination of two different swivel angles achieved by optimizing different cost functions based on kinematic and dynamic criteria. The kinematic criterion is to maximize the projection of the longest principal axis of the manipulability ellipsoid for the human arm on the vector connecting the wrist and the virtual target on the head region. The dynamic criterion is to minimize the mechanical work done in the joint space for each two consecutive points along the task space trajectory. As a first step, the redundancy based on the kinematic criterion will be thoroughly studied based on the motion capture data analysis. Experimental results indicate that by using the proposed redundancy resolution criterion in the kinematic level, error between the predicted and the actual swivel angle acquired from the motor control system is less than five degrees.

Derivation of Relation between Variation of Gradients of Antenna Tower of GNSS Permanent Observatories Depending on Diurnal Variation of External Air Temperature and Movement of Phase Center of Antenna (바깥 공기 온도의 일변화에 의한 GNSS 상시관측소 안테나탑 기울기 변화와 안테나 위상중심 위치의 운동 사이의 관계 추출)

  • Lim, Mu-Taek;Kwak, Byung-Wook;Park, Yeong-Sue;Rim, Hyoung-Rae
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.208-214
    • /
    • 2009
  • Using the GNSS data and tilt-meter data of Boeun (BOEN) and Goesan (GSAN) GNSS stations, we have calculated the differential distance vector variation with the calculation time span set to 1 hour and 3 hour and differential tilt vector variation along time and derived an indicator of similarity between the two variations along time. The similarity such calculated is rather lower than high. But as the existence of a circular type movement of the antenna's phase center's location due to the tilt's variation of the antenna tower because of the sunlight's diurnal change is certain, we recommend to take such diurnal variation of antenna's location into consideration when the correction error in DGNSS or the measured data at reference stations in VRS (Virtual Reference System) is broadcast.

Change of Brain Activation due to Change of Viewpoint in Action during Action Observation: an EEG Analysis Study (동작관찰 중 동작 수행 시 시점의 변화에 따른 뇌 활성의 변화)

  • Kim, Oi-Jin;Sim, Ji-Young;Lee, Se-Young;Jin, Hyun-Jin
    • PNF and Movement
    • /
    • v.14 no.3
    • /
    • pp.209-217
    • /
    • 2016
  • Purpose: Treatments using a mirror neuron system, such as 3D virtual reality therapy, are used in stroke rehabilitation, but they need to be constructed according to a detailed procedure. The aims of this study were to analyze electroencephalograms (EEG) during relaxation and action while observing first person perspective (1AE) and third person perspective (3AE) videos of the right hand for 20's. Methods: Thirty participants (Male=4, Female=26) were recruited for this study. Participants were selected by a vividness of movement imagery questionnaire (VMIQ). EEG was measured during relaxxation and during action with 1AE and 3AE videos, focusing on the supination and pronation actions of participants' right hands. An absolute mu rhythm, a relatively high alpha power, and a relative beta power were identified. In each group, one-way repeated measures ANOVA was used for statistical analysis. Results: Measurement of absolute mu rhythms was significantly suppressed for both 1AE and 3AE compared with relaxation in C3 and C4 regions. High alpha wave measurements were significantly suppressed for both 1AE and 3AE in all regions, while beta wave measurements were significantly increased only for 3AE in F3 and F4 regions. Conclusion: Based on this study, we suggest that the mirror neuron system is activated during actions accompanied by action observation, especially actions with 3AE video observation, which can be a great therapeutic mathod in stroke rehabilitation.

Emotion-based Gesture Stylization For Animated SMS (모바일 SMS용 캐릭터 애니메이션을 위한 감정 기반 제스처 스타일화)

  • Byun, Hae-Won;Lee, Jung-Suk
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.5
    • /
    • pp.802-816
    • /
    • 2010
  • To create gesture from a new text input is an important problem in computer games and virtual reality. Recently, there is increasing interest in gesture stylization to imitate the gestures of celebrities, such as announcer. However, no attempt has been made so far to stylize a gestures using emotion such as happiness and sadness. Previous researches have not focused on real-time algorithm. In this paper, we present a system to automatically make gesture animation from SMS text and stylize the gesture from emotion. A key feature of this system is a real-time algorithm to combine gestures with emotion. Because the system's platform is a mobile phone, we distribute much works on the server and client. Therefore, the system guarantees real-time performance of 15 or more frames per second. At first, we extract words to express feelings and its corresponding gesture from Disney video and model the gesture statistically. And then, we introduce the theory of Laban Movement Analysis to combine gesture and emotion. In order to evaluate our system, we analyze user survey responses.

A Ship Motion Control System for Autonomous Navigation (지능형 자율운항제어를 위한 선박운동제어시스템)

  • 이원호;김창민;최중락;김용기
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.6
    • /
    • pp.674-682
    • /
    • 2003
  • Ship autonomous navigation is designated as what computerizes mental faculties possessed of navigation experts, which are building navigation plans, grasping the situation, forecasting the fluctuation, and coping with the situation. An autonomous navigation system, which consists of several subsystems such as navigation system, a collision avoidance system, several data fusion systems, and a motion control system, is based on an intelligent control architecture for the sake of integrating the systems. The motion control system, which is one of the most essential system in autonomous navigation system, controls its propulsion and steering gears to move the ship satisfying its hydrodynamic characteristics. This paper is the study on the ship movement control system and its implementation which are totally developed and run on virtual-world system. Receiving the high-level control values such as a waypoint presented from the collision avoidance system, the motion control system generates them to low-level control values for propulsion and steering devices. In the paper, we develop a ship motion controller using Oldenburger's theory based on mathematical fundamentals, and simulate it with various scenarios in order to verify its performance.

Research on EEG-based minimization plan of motion sickness (EEG 기반의 어지럼증 최소화 방안에 관한 연구)

  • Seo, Hyeon-Cheol;Shin, Jeong-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Motion sickness is dizziness symptom that occurs when movement detected in the vestibular organ and movement detected visually are collide with each other. When dizziness occurs, user complains of symptoms such as nausea and vomiting, sense of direction abnormality, and fatigue. These causes of dizziness are various and difficult to differentiate and treat the symptoms. Especially, among the types of dizziness VIMS(Visually Induced Motion Sickness) is a problem to solve in developing VR industry. These VIMS analysis can be done through user's vital signs measurement and feature analysis, and EEG characteristics analysis. Therefore, this paper is discuss the minimization of motion sickness caused by visual information based on EEG signal and present research trends related to it.

Comparison of Practical Usefulness of Respirational Radiation Treatment Using Geant 4 Simulation Code (Geant 4 시뮬레이션 코드를 이용한 호흡 동조 방사선치료의 유용성 비교)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.637-643
    • /
    • 2019
  • To verify internal movements of the body, a DICOM file obtained from CT and a Geant4 code were used to simulate lung cancer patients. In addition, the method is applied to measure the movement of tumor when the movement of t he tumor is located inhale and exhale by creating a virtual tumor in the self-produced moving phantom, and to check the distribution of dose in the treatment plan and the accuracy of tumor in PTV for respiratory and lung cancer patients. It was confirmed that 97% or more respiratory control radiation therapy was effective even if the moving area was more than 3cm, in the 40% to 70% range. Dose distribution with respiratory radiation therapy applied to moving targets, measured by film in the actuation phantom, was shown to be within a 3mm margin of error for dose distribution containing 90%. It was confirmed that for actual patient breathing curves, the treatment time may be shorter than that due to the longer expiratory time.