• Title/Summary/Keyword: Vicker's 경도

Search Result 33, Processing Time 0.022 seconds

Temperature and Dependence of the Microhardness of Rhenium Sheets (리늄판의 미세경도 온도 및 응력의존성)

  • Yun, Seok-Yeong;Lagerlof, K.P.D.
    • Korean Journal of Materials Research
    • /
    • v.10 no.5
    • /
    • pp.335-342
    • /
    • 2000
  • The microhardness of rhenium sheets was determined as a function of indentation load and temperature. The temperature dependence of the microhardness between room temperatures and $1000 ^{\circ}C$was studied using a hot microhardness tester equipped with a Vickers indenter. The load dependence of the microhardness was investigated using oth a Vickers and a Knoop indenter. The indentation size effect (ISE) was well explained using the normalized Meyers law. The hardness of the annealed rhenium sheet approached that of the as-rolled sheets at large indentation loads because of work-hardening under the indenter during indentation. The hardness at zero load(obtained from extrapolation of the load dependence of the hardness) suggested that the hardness is controlled by two different mech-anisms having different thermal activation. At low temperature the activation energy for the mechanism controlling the hardness was approximately 0.02 eV , Whereas at higher temperatures that was approximately 0.15eV. The tranisi-tion temperature between the two different controlling mechanisms was about $250^{\circ}C$.

  • PDF

FLUORIDE RELEASE AND RECHARGE OF GLASS IONOMER CEMENTS (글라스 아이오노머 수복재의 불소 유리 및 재흡수 양상)

  • Bae, Ik-Hyun;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.136-143
    • /
    • 2005
  • The replacement of dental restorations due to secondary caries is a continuing problem in restorative dentistry. The secondary caries can be partly prevented by using fluoride containing dental materials such as glass ionomer cement, which releases and be recharged with fluoride ion acting as a fluoride reservoir. For the purpose of investigating the behaviors of fluoride release and recharge of conventional and high viscosity glass ionomer cements, the experiment was performed on the seven specimens each from 4 kinds of materials ; 1 kind of conventional glass ionomer cement, 2 kinds of high viscosity glass ionomer cements and 1 kind of composite resin. The amount of fluoride release was measured over 7 days with pH/ion meter and fluoride specific electrode. After measuring daily fluoride release, the specimens were recharged with 2% NaF solutions for 4 minutes and measured for 3 days with recharging repeated two consecutive times. The results were as follows : 1. Significantly more fluoride was released at first day after recharge in all materials except Z-100. 2. High viscosity glass ionomer cements released more or nearly equal amount of fluoride after recharge compared with the initial release(P<0.05). 3. The fluoride release after recharge with 2% NaF solution was in order of Fuji IX, Ketac Fil, Ketac Molar, Z-100.

  • PDF

A Study on High Frequency Induction Hardening of S45C Specimen by FEA and Experiment (유한요소해석 및 실험에 의한 S45C 시편의 고주파 유도경화에 관한 연구)

  • Park, Kwan-Seok;Choi, Jin-kyu;Lee, Seok-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.5
    • /
    • pp.1-7
    • /
    • 2018
  • In this study, we proposed a high frequency induction hardening analysis method based on electromagnetic-thermal co-simulation. In the high frequency induction heating analysis, the results of the finite element analysis (FEA) (considering the change of the material property and the cooling factor according to the temperature) and those of the high frequency induction hardening experiment (using the S45C specimen) were compared. The hardness of the S45C specimens was measured using the micro Vickers hardness test to determine the depth of hardening. The measurement results were then compared with the results of FEA. The result of high frequency induction heating analysis showed that the temperature was more than $750^{\circ}C$, which is the A2 transformation point of S45C, while the temperature during quenching was below $200^{\circ}C$. The results showed that the difference of the depth of hardening between the FEA and the experiment is 0.2mm.

Tensile Strength of Plate with Bolt Hole and Bearing Strength of Bolted Connection by Oxygen Torch Cut (볼트홀을 산소토치로 천공한 강재의 인장강도 및 지압이음강도)

  • Park, Yong Myung;Lee, Kun Joon;Kim, Dong Hyun;Ju, Ho Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.617-626
    • /
    • 2014
  • In this paper, experiments for the evaluation of tensile strength of steel plate with bolt hole and bearing strength of bolted connection were performed, where bolt holes were punched by drilling and oxygen torch, respectively. For the tensile tests, drilled and oxygen torch punched steel plate specimens of 10mm and 15mm thickness were made from structural angles and H-shapes, respectively. For the bearing strength evaluation, test specimens were fabricated with base plates and splice plates those were also punched by drilling and oxygen torch, respectively. The Vicker's hardness were measured around the bolt hole to investigate material property change due to heat effect by oxygen torch cut. Numerical analysis was also performed to investigate the bearing strength of bolted joints due to the increase of hardness around the bolt hole by oxygen torch cut.

Creep Damage and Hardness Properties for 9Cr Steel by SP-Creep Test Technique (SP-Creep 시험기법에 의한 9Cr강의 크리프 손상과 경도 특성)

  • Baek, Seung-Se;Lyu, Dae-Young;Kim, Jeong-Ki;Kwon, Il-Hyun;Chung, Se-Hee;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.105-110
    • /
    • 2001
  • It has recently been raised main issue how solve the problem of insufficient energy. One of the solution is to increase the thermal efficiency of power generation system. For the purpose of high efficiency, it is necessary to increase the steam temperature and pressure. So, the use of modified $9{\sim}12%Cr$ steel having superior creep rupture strength and oxidation resistance is required to endure such severe environment. The evaluation of creep properties of those heat resistance material is very important to secure the reliability of high temperature and pressure structural components. Since creep properties are determined by microstructural change such as carbide precipitation and coarsening, It is certain that there are some relationship between creep properties and hardness affected by microstructure. In this study, SP-Creep ruptured test for newly developed 9Cr steel being used as boiler valve material was performed, and creep properties of the material were evaluated. Also, hardness test were performed and hardness results were related to the creep properties such as LMP and creep strength to verify the availability of SP-Creep test as creep test method.

  • PDF

THE EFFECT OF ENVIRONMENT ON THE PHYSICAL PROPERTIES OF CORE MATERIALS (지대치 재료의 환경변화에 따른 물리적 성질에 관한 연구)

  • Hwang, Yoo-Sook;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.86-94
    • /
    • 2005
  • The purpose of this study was to measure the flexural strength and hardness of four core materials in 4 different medias and to evaluate the relationship between the physical properties. For the flexural strength, the specimens were prepared from each of the following materials: Bisfil Core, Core Max, Fuji IX GP, Miracle Mix and randomly divided into four groups and stored at 37 degree C in the following medias: distilled water for 24 hours (DW/1), distilled water for 30 days (DW/30). $2%$ NaF for 30 days (NF/30), 0.02N lactic acid for 30 days (LA/30). After storage, the specimens were subjected to flexural strength testing and calculated to flexural modulus. For hardness testing, specimens were prepared from four materials and storaged in the uniform way. After storage, the specimens were subjected to Vicker's hardness testing. 1. The flexural strength of Core Max were the highest, and the flexural strength of Miracle Mix were the lowest. 2. The hardness of Bisfil Core were the highest. 3. The hardness of Core Max were the highest. 4. The hardness of Miracle Mix were the lowest. 5. $2\%$ NaF and 0.02N lactic acid negatively affected the flexural strength and hardness of four core materials.

다양한 온도의 Age-hardening에 따른 14K, 18K White gold의 경도 변화

  • Yun, Don-Gyu;Seo, Jin-Gyo;An, Yong-Gil;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.322-322
    • /
    • 2011
  • White gold는 아름다운 광택과 손쉬운 가공성의 장점 때문에 장신구를 비롯한 다양한 분야에서 그 활용 가치가 매우 높다. 본 연구에서 우리는 열처리를 통한 white gold의 hardness강화 및 품질향상을 위하여 다양한 열처리 조건별 기계적 특성변화를 비교 관찰 하였다. 열처리 전 white gold alloy의 구성성분을 조사하기 위하여 EPMA와 ICP-MS를 사용하여 분석 후 그 값을 수치화 하였다. 14K, 18K White gold alloy 총 32개의 시료를 사용하여 $750^{\circ}C$, 30 min의 조건에서 solid treatment 및 quenching 후 $200^{\circ}C{\sim}350^{\circ}C$ 온도 범위에서 $50^{\circ}C$ 간격으로 age-hardening을 실시하였다. 열처리 전과 후 각 조건별 hardness 변화는 Vicker's hardness tester를 사용하여 측정하였다. 또한 age-hardening 후 모든 시료는 optical microscope (OM)을 사용하여 각 열처리 조건 별 grain 들의 배열 및 size의 변화를 관찰하였다. 열처리 전 14K, 18K white gold alloy의 hardness의 평균값은 각각 162 Hv와 196 Hv를 나타내었다. solid treatment 후 그 수치가 146 Hv, 172 Hv로 감소하였고, age-hardening 후에는 hardness 값이 점차 증가하여 14K는 $260^{\circ}C$에서 226 Hv, 18K는 $270^{\circ}C$에서 268 Hv의 가장 높은 수치를 나타내었다. 또한 14K 및 18K는 각각 $260^{\circ}C$, $270^{\circ}C$ 이상에서는 over-aging 현상을 나타내었다. OM 분석 결과 열처리 전 불균일했던 grain들의 배열이 solid treatment 및 quenching 후 다소 균일해짐을 확인할 수 있었고, grain size 또한 열처리 전에 비해 증가함을 알 수 있었다. Solid treatment 후 모든 시료의 hardness값이 전반적으로 감소하였다가 age-hardening을 통해 grain들의 배열이 점차 안정화 되면서 hardness가 증가 하였고, over-aging 구간에서는 급격히 감소하는 경향을 나타내었다. 이 결과들로부터 우리는 14K, 18K white gold alloy 에 대한 age-hardening 최적조건을 도출하였고, 각 열처리 조건별 grain 배열 상태의 변화를 관찰 할 수 있었다.

  • PDF

The Study of Corrosion Behavior for Solution and Aging Heat Treated Ti alloy (Ti 합금의 용체화열처리와 시효열처리에 따른 부식거동)

  • Baik, Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.138-144
    • /
    • 2016
  • Titanium is resistant to general corrosion and in sea water because of the passivity layer film on the surface of material, but may be attacked by environments that cause breakdown of the protective oxide layer including hydrochloric, sulfuric and phosphoric acids. In this study, the Ti alloys were solution heat treatment 5hours at $1066^{\circ}C$ and $966^{\circ}C$, and followed by aging heat treated, 1, 4, 8 and 16 hours in $500^{\circ}C$, $600^{\circ}C$ and $650^{\circ}C$ respectively. The heat treated specimens were measured micro Vicker's hardness, and then accomplished electrochemical polarization test for comparing corrosion in 1N sulfuric acid solution. Additionally, micro structures were taken for corrosion tested specimens. The results showed that corrosion resistance was higher in solution heat treated alloy than base and age heat treated metal. Measured corrosion resistants were increased as increasing aging heat treatment time and temperature.

THE EFFECTS OF WAVELENGTH AND INTENSITY OF VISIBLE LIGHT ON THE CURING OF VISIBLE LIGHT CURED COMPOSITE RESIN (가시광선의 파장과 광도가 광중합형 복합레진의 경화에 미치는 영향)

  • Lee, Chae-Gyeong;Hur, Bok
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.149-159
    • /
    • 1989
  • The purpose of this study was to assess the effects of wavelength and intensity of light curing units on the curing of composite resin. The wavelength and intensity of nine units were evaluated with Optical Multichannel Analyzer and Radiometer. Two-part split stainless steel mold with a cylindrical hole-3.0mm in diameter, 6.0mm in hgieht-was prepared. After placing a Mylar strip between two parts, 100 specimens were made by inserting each of four composite resins into the mold and irradiating for 20 seconds with five light units alternatively. The curing depths were measured by scraping method and evaluated by two-way ANOVA. And Vicker's hardness measurements were made on the longitudinally sectioned surface at 0.5mm interval. The results were as follows: 1. Visilux 2 showed a narrow spectral band within the effective wavelength in initiating polymerization and the highest intensity. Translux showed the diffuse spectrum of wavelength and the lower light intensity. 2. Visilux 2 showed the highest curing effect in any composite resin and then followed by Optilux, Efos 35, Heliomat and Translux. (p < 0.01) 3. Durafill showed the deepest curing depth in any light unit and then followed by Bisfil M, Silux and Heliosit. (p < 0.01). 4. Maximum hardness values showed 0.1mm and 0.5mm under top surface and then gradually decreased with depth.

  • PDF

Experimental Research on the Effect of the Number of Layers by Overlay Welding of Monel-Clad Pipe on Weldability (모넬(Monel)-Clad 파이프의 오버레이 용접 적층수가 용접성에 미치는 영향에 관한 실험적 연구)

  • Choi, Hyeok;Park, Joon-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.42-50
    • /
    • 2016
  • Overlay welding affects the chemical components and weld hardness by dilution of the lamination layer thickness, which determines the surface properties. This study experimentally investigates different numbers of layers for overlay welding monel materials, which are anti-corrosion materials. The Fe content, weldability of the base metal and monel materials, hardness, and surface flatness were examined. Each evaluation was carried out after overlay welding with three layers on the base material and pipe base material of the plate. The Fe content was evaluated by analyzing the constituents of each layer. The Fe content was satisfactory in the three layers. The weldability of the laminate specimens was evaluated by a bending test. The hardness and bead flatness of the laminate specimens were evaluated by micro Vickers and 3D measurements. The hardness was highest in the heat-affected zone with one layer, and it decreased with increasing lamination. In the case of bead flatness, there is a sharp difference in the deviation with increasing numbers of laminations, which should be considered carefully.