• Title/Summary/Keyword: Vibrations

Search Result 2,381, Processing Time 0.028 seconds

Vibration measurement and vulnerability analysis of a power plant cooling system

  • Anil, Ozgur;Akbas, Sami Oguzhan;Kantar, Erkan;Gel, A. Cem
    • Smart Structures and Systems
    • /
    • v.11 no.2
    • /
    • pp.199-215
    • /
    • 2013
  • During the service life of a structure, design complications and unexpected events may induce unforeseen vibrations. These vibrations can be generated by malfunctioning machinery or machines that are modified or placed without considering the original structural design because of a change in the intended use of the structure. Significant vibrations occurred at a natural gas plant cooling structure during its operation due to cavitation effect within the hydraulic system. This study presents findings obtained from the in-situ vibration measurements and following finite-element analyses of the cooling structure. Comments are made on the updated performance level and damage state of the structure using the results of these measurements and corresponding numerical analyses. An attempt was also made to assess the applicability of traditional displacement-based vulnerability estimation methods in the health monitoring of structures under vibrations with a character different from those due to seismic excitations.

Coupled Vibration of Lateral and Torsional Vibrations in a Rotating Shaft Driven through a Universal Joint - Derivation of Equations of Motion and Stability Analysis - (유니버셜 조인트에 의해 구동되는 회전축의 횡진동과 비틀림진동의 연성진동 - 운동방정식의 유도 및 안정성해석 -)

  • 김정렬;전승환;이돈출
    • Journal of KSNVE
    • /
    • v.9 no.3
    • /
    • pp.461-465
    • /
    • 1999
  • This paper presents theoretical analyses for unstable vibrations caused by the couple of bending and torsion in a rotating shaft driven through a universal joint. A driving shaft is assumed to be rigid and to rotate with a constant angular velocity. The driven shaft system consists of a flexible shaft with a circular section and a symmetrical rotor attached at a point between the shaft ends. Equations of motion derived hold with an accuracy of the second order of shaft deformations, and are analyzed by the asymptotic method. The vibrations become unstable when the driving shaft rotates with the angular velocity to be approximately equal to half of the sum of the natural frequencies for whirling and torsional vibrations.

  • PDF

Wind tunnel studies of cantilever traffic signal structures

  • Cruzado, Hector J.;Letchford, Chris;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.16 no.3
    • /
    • pp.225-240
    • /
    • 2013
  • The wind-induced vibrations of the mast arm of cantilever traffic signal structures can lead to the fatigue failure of these structures. Wind tunnel tests were conducted on an aeroelastic model of this type of structure. Results of these experiments indicated that when the signals have backplates, vortex shedding causes large-amplitude vibrations that could lead to fatigue failure. Vibrations caused by galloping were only observed for one particular angle of attack with the signals having backplates. No evidence for galloping, previously thought to be the dominant cause of fatigue failures in these structures, was observed.

Analysis of local vibrations in the stay cables of an existing cable-stayed bridge under wind gusts

  • Wu, Qingxiong;Takahashi, Kazuo;Chen, Baochun
    • Structural Engineering and Mechanics
    • /
    • v.30 no.5
    • /
    • pp.513-534
    • /
    • 2008
  • This paper examines local vibrations in the stay cables of a cable-stayed bridge subjected to wind gusts. The wind loads, including the self-excited load and the buffeting load, are converted into time-domain values using the rational function approximation and the multidimensional autoregressive process, respectively. The global motion of the girder, which is generated by the wind gusts, is analyzed using the modal analysis method. The local vibration of stay cables is calculated using a model in which an inclined cable is subjected to time-varying displacement at one support under global vibration. This model can consider both forced vibration and parametric vibration. The response characteristics of the local vibrations in the stay cables under wind gusts are described using an existing cable-stayed bridge. The results of the numerical analysis show a significant difference between the combined parametric and forced vibrations and the forced vibration.

An investigation on the vibrations of laminated shells under aeroacoustic loads using a WFE approach

  • Errico, Fabrizio;Franco, F.;Ichchou, M.;De Rosa, S.;Petrone, G.
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.6
    • /
    • pp.463-478
    • /
    • 2019
  • The present work investigates the effect on the flow-induced vibrations of the lay-up sequence of composite laminated axisymmetric structures, using an hybrid approach based on a wave finite element and a transfer matrix method. The structural vibrations, under deterministic distributed pressure loads, diffuse acoustic field and turbulent boundary layer excitations, are analysed and compared. A multi-scale approach is used for the dynamic analysis of finite structures, using an elementary periodic subsystem. Different flow regimes and shell curvatures are analysed and the computational efficiency is also discussed.

Recent Developments in Multibody Dynamics

  • Schiehlen Werner
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.227-236
    • /
    • 2005
  • Multibody system dynamics is based on classical mechanics and its engineering applications originating from mechanisms, gyroscopes, satellites and robots to biomechanics. Multibody system dynamics is characterized by algorithms or formalisms, respectively, ready for computer implementation. As a result simulation and animation are most convenient. Recent developments in multibody dynamics are identified as elastic or flexible systems, respectively, contact and impact problems, and actively controlled systems. Based on the history and recent activities in multibody dynamics, recursive algorithms are introduced and methods for dynamical analysis are presented. Linear and nonlinear engineering systems are analyzed by matrix methods, nonlinear dynamics approaches and simulation techniques. Applications are shown from low frequency vehicles dynamics including comfort and safety requirements to high frequency structural vibrations generating noise and sound, and from controlled limit cycles of mechanisms to periodic nonlinear oscillations of biped walkers. The fields of application are steadily increasing, in particular as multibody dynamics is considered as the basis of mechatronics.

Linux/RTAI-based Input Shaping Implementation for Suppressing Residual Vibrations (Linux/RTAI기반의 잔류진동 억제 입력성형 구현)

  • Woo, Kyo-Sik;Kim, Jin-Woo;Kang, Chul-Goo;Lee, Dong-Je;Park, Kyung-Hee;Kim, Hyung-Chul
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.3
    • /
    • pp.250-256
    • /
    • 2009
  • Suppressing residual vibrations of flexible materials cheaply is an important issue to increase productivity of automated factory using wafer or glass handling robots. In this paper, we present Linux/RTAI-based implementation of input shaping control for reducing residual vibrations of a mechanical system. Experimental results show that residual vibrations of the mechanical system are reduced up to 82% at a point-to-point linear motion.

  • PDF

Effects of Artificial Vibrations on Strength and Physical Properties of Curing Concrete (인공진동의 크기가 양생콘크리트의 강도와 물성에 미치는 영향)

  • 임한욱;정동호;이상은
    • Tunnel and Underground Space
    • /
    • v.4 no.1
    • /
    • pp.31-37
    • /
    • 1994
  • The effects of blasting and ground vibratons on curing concrete have not been well studied. As a results unrealistic and costly ground vibration constraints have been placed on blasting and piling when it occurs in the vicinity of curing concrete. To study the effects of ground vibrations, a shaking table was made to produce peak particle velocities in the nearly same frequency range as found in construction blasting. Concrete blocks of 33.3X27.7X16.2cm were molded and placed on the shaking table. Different sets of concrete blocks were subjected to peak vibrations of 0.25, 0.5, 1.0, 5.0 and 10cm/sec. The impulses were applied at two hour intervals for thirty seconds. Along with unvibrated concrete blocks, the vibrated concrete samples with 60.3mm in diameters were measured for elastic moduli, sonic velocity, tensile and uniaxial compressive strength. Test results showed that the vibrations in curing concrete generally have effects on the uniaxial compressive strength or physical properties of the concrete.

  • PDF

A study of commercial vehicle cab vibration on the driving conditions (상용 차량의 주행 중 발생하는 캡의 진동에 관한 연구)

  • Choi, Byungjae;Han, In-kyu;Cho, Jeong-wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.472-475
    • /
    • 2014
  • Abnormal cab vibrations in the Y direction in commercial vehicles during driving(70~90kph) are not common vibrations that happen to vehicles during driving and can be an obstacle to normal driving. This study conducted Operation Deflection Shape(ODS) testing to identify the causes of those abnormal cab vibrations and find solutions for them and also a sine sweep test to find resonance and frequency in the cab suspension system and set directions for improvement. The study also altered the shape of the bush inner part for changes to the rigidity features of the cab bush in the Y direction and revised the design with optimal rigidity in the Y direction, thus improving abnormal cab vibrations in the Y direction during driving.

  • PDF

The Influence of Ground Vibration Caused by Pile Driving on Power Line Tower Foundation (항타 진동이 송전탑 기초에 미치는 영향 연구)

  • Park, Jung-Bong
    • Explosives and Blasting
    • /
    • v.27 no.2
    • /
    • pp.42-47
    • /
    • 2009
  • Ground vibrations caused by pile driving or explosive blasting can affect the stability of power line tower and its foundation. Because the characteristics of ground vibrations generally depend on the distances from the blast, the ground vibrations should be controlled by taking the distance into account. In this study, ground vibration levels were measured at the foundation of a power line tower and on ground surface adjacent to the tower. The relationships between the dominant frequencies of the ground vibrations that were measured at both locations were comparatively investigated.