• 제목/요약/키워드: Vibration of Joint

검색결과 440건 처리시간 0.029초

Comparison of the Immediate Effect of the Whole-body Vibration on Proprioceptive Precision of the Knee Joint Between Barefoot and Shoe-wearing Conditions in Healthy Participants

  • Lee, Yu-bin;Hwang, Ui-jae;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제28권2호
    • /
    • pp.108-116
    • /
    • 2021
  • Background: Whole-body vibration (WBV) has been used to alleviate proprioceptive damage by musculoskeletal and neurological conditions. However, no study has determined whether wearing shoes while applying WBV can affect proprioception precision of the knee joint. Objects: This study aimed to determine the differences in the proprioceptive precision of the knee joint before and after WBV and to compare the proprioceptive precision of the knee joint between barefoot and shoe-wearing conditions. Methods: This study recruited 33 healthy participants. A passive-to-active angle reproduction test was used to measure the proprioception precision of the knee joint using an electrogoniometer, and the target angle was set to a knee flexion of 30°. Proprioception precision was calculated using the error angle (angular difference from 30°). Proprioceptive precision was measured in weight-bearing and non-weight-bearing positions before and after applying WBV for 20 minutes at 12 Hz in barefoot and shoe-wearing conditions. Mixed repeated analysis of variance was used to determine the differences in changes in the proprioceptive precision of the knee joint according to foot conditions. Results: There were significant improvements in the weight-bearing (p = 0.002) and non-weight-bearing (p < 0.001) proprioceptive precision of the knee joint after applying WBV. However, there was no significant difference in the change in proprioceptive precision of the knee joint after applying WBV between the barefoot and shoe-wearing conditions. Conclusion: WBV stimulation had an immediate effect on improving the proprioceptive precision of the knee joint. However, foot conditions (barefoot or shoe-wearing) during WBV application did not influence the proprioceptive precision of the knee joint.

동일 평면상에서 연성된 평판구조물 진동의 파워흐름해석 (Vibration Power Flow Analysis of Coupled co-planar Plate Structures)

  • 박도현;홍석윤;길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.311-318
    • /
    • 1998
  • In this paper, the power flow analysis(PFA) method is applied to the prediction of the vibrational energy density and intensity of coupled co-planar plates. To cover the energy transmission and reflection at the joint of the plates, the wave transmission approach is introduced with the assumption that all the incident waves are normal to the joint. By changing the frequency ranges and internal loss factors, we have obtained the PFA results, and compared them with the analytical exact solutions.

  • PDF

악관절진동의 임상적 관련요인에 관한 연구 (A Study on the Clinical Factors Related to Vibration of Temporomandibular Joint)

  • 김종영;남천우;한경수
    • Journal of Oral Medicine and Pain
    • /
    • 제24권1호
    • /
    • pp.37-47
    • /
    • 1999
  • This study was performed to investigate the factors related to vibration of temporomandibular joint during mandibular opening movement. For this study, 144 patients with temporomandibular disorders were randomly selected. Angle's classification, lateral guidance pattern, range of maximal mouth opening, preferred chewing side, and affected side were investigated clinically. Mandibular torque rotational movement during opening was recorded with $BioEGN^{(R)}$ and vibration of temporomandibular joint during opening was recorded with $Sonopak^{(R)}$. After clinical diagnosis was made, visual analogue scale(VAS) was used for evaluation of clinical progress of the subject's chief complaints. The author calculated VAS treatment index(VAS Ti) from the record of VAS. The more VAS Ti was, the less remission of subjective symptom was, The data were analyzed with SAS/Stat program and the results of this study were as follows: 1. There were no significant difference in all the variables of joint vibration by age and sex. 2. Integral and peak amplitude in patients of Angle's class I were higher than those of class II or III patients. Integral in patients of group function was higher than that in patients of canine guidance or other types of lateral excursion. 3. As to Angle's classification or lateral guidance type, there were almost not significant difference between subgroup of same class or type and subgroup of different class or type on both sides. And there were also almost not difference between one side and the other side related to preferred chewing side or affected side. 4. Patients with disk displacement with reduction showed higher value of integral and peak amplitude than any other patients. 5. Joint vibration variables significantly correlated with VAS Ti of pain. with clinical range of mouth opening, and with ingredients of mandibular torque rotational movement.

  • PDF

사용차 구동축의 진동발생 메카니즘의 규명 (Vibration Excitation Mechanism of Commercial Vehicle Driveline)

  • Park, B.Y.
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.109-119
    • /
    • 1995
  • A driveline incorporating universal joints when driving through an angle can excite various components in a vehicle with second order excitation of torsional and bending vibrations, being transmitted either audibly(noise), or physically(vibration). For a certain range of vehicle dpeed noises can be radiated from the cab wall, in which resonances occur by the excitations transmitted from the driveline as a vibration source. In this paper, the excitation mechanism of cab noises is studied especially for the vehicle speed range of 65 .approx. 75 km/h through the simulation for torsional vibrations of the driveline and for bending vibrations of the cab of an 11 Ton grade Cargo Truck, and verified additionally by vibration and noise measurements. As a result, it is found that the uncomfortable noises in the cab are caused mainly by the abrupt increase of the joint angle of driveline near the axle differential resulted from the excessive clearance alignment of the leaf spring gate.

  • PDF

신축이음장치의 진동소음 실험 (Expansion Joints for Vibration and Noise Test)

  • 곽종원;김영진;이정우;최은석;진원종
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.513-516
    • /
    • 2004
  • Consistency in design, manufacture, installation and performance test of expansion joints is insufficient for guarantee of reliability because they are imported from various foreign countries as America, Japan and Europe. In addition to that, the regulations or codes of expansion joint should be revised and established for levels of vibration and noise generated from riding vehicles especially. Regulation on the noise neighboring traffic roads is established by ministry of environment. Therefore, Field tests on the vibration and the noise at expansion Joints, especially rail-type and finger-type joints which are typical ones in bridge with short or middle span, are performed and performance of expansion joints are analyzed. And so, the results of the investigation will be utilized as basic data for the regulation on the vibration and the noise.

  • PDF

LabVIEW® 기반 6축 수직 다관절 로봇(RS2)의 이종 모션 블랜딩 연구 (Implementation of LabVIEW®-based Joint-Linear Motion Blending on a Lab-manufactured 6-Axis Articulated Robot (RS2))

  • 이동선;정원지;장준호;김만수
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.318-323
    • /
    • 2013
  • For fast and accurate motion of 6-axis articulated robot, more noble motion control strategy is needed. In general, the movement strategy of industrial robots can be divided into two kinds, PTP (Point to Point) and CP (Continuous Path). Recently, industrial robots which should be co-worked with machine tools are increasingly needed for performing various jobs, as well as simple handling or welding. Therefore, in order to cope with high-speed handling of the cooperation of industrial robots with machine tools or other devices, CP should be implemented so as to reduce vibration and noise, as well as decreasing operation time. This paper will realize CP motion (especially joint-linear) blending in 3-dimensional space for a 6-axis articulated (lab-manufactured) robot (called as "RS2") by using LabVIEW$^{(R)}$ (6) programming, based on a parametric interpolation. Another small contribution of this paper is the proposal of motion blending simulation technique based on Recurdyn$^{(R)}$ V7 and Solidworks$^{(R)}$, in order to figure out whether the joint-linear blending motion can generate the stable motion of robot in the sense of velocity magnitude at the end-effector of robot or not. In order to evaluate the performance of joint-linear motion blending, simple PTP (i.e., linear-linear) is also physically implemented on RS2. The implementation results of joint-linear motion blending and PTP are compared in terms of vibration magnitude and travel time by using the vibration testing equipment of Medallion of Zonic$^{(R)}$. It can be confirmed verified that the vibration peak of joint-linear motion blending has been reduced to 1/10, compared to that of PTP.

박판보 요소와 셸 요소를 이용한 T 조인트 진동 해석 (Free Vibration Analysis of a T Joint Using Thin-Walled Beam and Shell Elements)

  • 김진홍;김현석;김윤영
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2334-2343
    • /
    • 2000
  • This paper proposes an efficient beam-shell modeling technique for the free vibration analysis of a T-joint thin-walled beam structure. Except a small portion of a T-joint which is modeled by shell elements, the structure is modeled by thin-walled beam elements that can describe warping and distortion. In order to match the shell and thin-walled beam elements at the interface of the dissimilar elements, a technique based on a pseudo inverse matrix is formulated. This paper also examines the role of the thin-walled element taking into account the distortion and warping deformation degrees of freedom in predicting accurately the dynamic characteristics of a T-joint thin-walled structure.

볼트 결합부의 동적 파라미터 해석 (Dynamic Parameter Analysis of Bolted Joint)

  • 백성남;지태한;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1994년도 추계학술대회논문집; 한국종합전시장, 18 Nov. 1994
    • /
    • pp.244-249
    • /
    • 1994
  • The dynamic characteristics of mechanical structure are strongly affected by the properties of joint parameters. In this study, the test structures are constructed with two beam structures which are clamped by bolts, and a bolted joint which is modelled as a lumped stiffness element. To identify the dynamic joint parameters with variance of clamping torque of bolts, the sensitivity analysis and the mode energy analysis methods are investigated experimentally. As a result of these two methods, stiffnesses of bolted joint are experimentally found to increase as the clamping torque increases. These stiffnesses identified from the sensitivity analysis and the mode energy analysis method have some difference.

  • PDF

차륜주행충격에 의한 빗살형 교량 신축이음장치 구조물의 과도진동해석 (Transient Response Analysis of a Comb Type Bridge Expansion Joint due to Travelling Wheel Impact)

  • 최영휴;김현욱;안영덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.69-74
    • /
    • 1997
  • In this paper we derive relations which describe the geometry and kinematics of contact between the travelling wheel and stepped comb joint. From which we can obtain the impulse, impulsive force and its time interval due to travelling wheel impact which can not be taken from Carter's model or Newland and Cassidy's. The calculated transient responses of the comb joint structure to travelling wheel impact reveals that the proposed wheel contact model and Carter's give very similar results but Newland Cassidy's model make a quite different results from the others.

  • PDF

만성발목불안정성 환자의 진동자극이 가동범위 및 고유수용성감각에 미치는 즉각적인 효과: 무작위 교차 연구 (Immediate Effects of Vibration Stimulation on the Range of Motion and Proprioception in Patients with Chronic Ankle Instability: Randomized Crossover Study)

  • 박치복;박성환;정호진;김병근
    • 대한물리의학회지
    • /
    • 제18권1호
    • /
    • pp.9-14
    • /
    • 2023
  • PURPOSE: This study examined the effect of vibration stimulation of a vibration foam roller on the change in the range of motion of the ankle joint and proprioception in patients with chronic ankle instability. An additional aim was to provide basic data for rehabilitation programs for chronic ankle instability patients. METHODS: This study was a randomized crossover design of 22 patients with chronic ankle instability. All subjects were divided into a vibrating group, a non-vibrating group, and a control group. The vibration and non-vibration groups performed the interventions, but the control group did not. For the measurement, the range of motion and proprioception of the ankle joint was measured using an electronic protractor (Electrogoniometer, BPM Pathway, UK). RESULTS: The vibration group showed significant differences in the dorsiflexion angle, dorsiflexion proprioception, and plantar flexion proprioception (p < .05). The non- vibration group showed significant differences in the dorsiflexion angle and dorsiflexion proprioceptive sensation (p < .05). The vibration group and the control group showed significant differences in dorsiflexion proprioception and plantar flexion proprioception (p < .05). CONCLUSION: The range of motion and proprioception of the ankle joint were improved in the group that received vibration stimulation after the intervention than before the intervention. Future research will be needed on patients with various diseases.