• 제목/요약/키워드: Vibration Sensor

검색결과 1,199건 처리시간 0.026초

모달필터 성능을 고려한 센서의 최적위치 (Sensor Placement in Structural Vibration Control For the Performance of Modal Filter)

  • 황재혁;김준수;백승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.308-315
    • /
    • 1997
  • In this study, the effect of modal filter error on the vibration control characteristics of flexible structures is analyzed for IMSC(Independent Modal Space Control), and optimal sensor placement in the structural vibration control with consideration of performance of modal filter has been studied. An Lyapunov asymptotic stability condition has been derived, which depends on the magnitude of the modal filter errors. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator techniques. A sensor placement technique has also been suggested to maximize the performance of the modal filter. It has been found by a series of simulation that the suggested sensor placement technique is very effective on the determination of the number and placement of sensors of modal filter in the structural vibration control.

  • PDF

복합 신경회로망을 이용한 채터진동의 인프로세스 감시(II) (In-Process Monitoring of Chatter Vibration using Multiple Neural Network(II))

  • 김정석;강명창;박철
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.100-108
    • /
    • 1995
  • The In-process minitoring of the chatter vibration is necessarily required to an automatic manufacturing system. In this study, we constructed a multi-sensing system using tool dynamoneter, accelerometer and AE(Acoustic Emission) sensor for a more credible detection of chatter vibration. And a new approach using a multiple neural network to extract the features of multi-sensor for the recognition chatter vibration is proposed. With the Back-propagation training process, the neural network memorize and classify the features of multi-sensor signals. As a result, it is shown by multiple neural network that the chatter vibration can be monitored accurately, and it can be widely used in practical unmanned system.

  • PDF

Ambient Vibration-Measurement of Real Building Structure by Using Fiber Optic Accelerometer System

  • Kim, Dae-Hyun
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.373-379
    • /
    • 2006
  • Vibration-based structural health monitoring is one of non-destructive evaluation (NDE) techniques for civil infrastructures. This paper presents a novel fiber optic accelerometer system to monitor civil engineering structures and a successful application of the novel sensor system for measuring ambient vibration of a real building structure. This sensor system integrates the Moire fringe phenomenon with fiber optics to achieve accurate and reliable measurements. The sensor system is immune to electromagnetic (EM) interference making it suitable for difficult applications in such environments involving strong EM fields, electrical spark-induced explosion risks, and cabling problems, prohibiting the use of conventional electromagnetic accelerometers. A prototype sensor system has been developed, together with a signal processing software. The experimental studies demonstrated the high-performance of the fiber optic sensor system. Especially, the sensor was successfully used for monitoring a real building on UCI (University of California Irvine, USA).

구배법을 이용한 진동제어용 압전 감지기/작동기의 위치 최적화 (Optimization of Piezoceramic Sensor/Actuator Placement for Vibration Control using Gradient Method)

  • 강영규;박현철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.684-688
    • /
    • 1998
  • Optimization of the collocated piezoceramic sensor/actuator placement is investigated numerically and verified experimentally for vibration control of laminated composite plates. The finite element method is used for the analysis of dynamic characteristics of the laminated composite plates with the piezoceramic sensor/actuator. The structural damping index(SDI) is defined from the modal damping. It is chosen as the objective function for optimization. Weights for each vibrational mode are taken into account in the SDI calculation. The gradient method is used for the optimization. Optimum location of the piezoceramic sensor/actuator is determined by maximizing tie SDI. Numerical simulation and experimental results show that the optimum location of the piezoceramic sensor/actuator is dependent upon the outer layer fiber orientations of the plate, and location and size of the piezoceramic sensor/actuator.

  • PDF

유한요소해석을 이용한 GIS용 AE 센서의 설계와 특성 (Design and Characteristics of AE Sensor for GIS by Finite Element Analys)

  • 홍재일;이병효;김일남;조태경;류주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-55
    • /
    • 2000
  • In this paper, the coupled and the non-coupled vibration mode AE sensor for GIS were simulated by finite element analysis and manufactured, and characterized. The maximum sensitivity was 64.3 dB when the resonant frequency of the coupled vibration mode AE sensor was 166 kHz and the maximum sensitivity was 58.9 dB when the resonant frequency of the non-coupled mode AE sensor was 265 kHz. The coupled vibration mode AE sensor responded higher than the non-coupled vibration mode AE sensor at the partial discharge detection in GIS.

  • PDF

압전저항형 멤스센서를 이용한 진동 측정용 3축 센서 시스템의 최적화 설계 (Optimum Design of 3-Axis Sensor System for Vibration Measurement Using Piezoresistive type MEMS Sensor)

  • 서상윤;배동명;이종규;최병근
    • 한국소음진동공학회논문집
    • /
    • 제23권12호
    • /
    • pp.1082-1089
    • /
    • 2013
  • 3-Axis sensor measurement system is needed for measuring ride quality of elevator. But because 3-Axis piezoelectric accelerometer is expensive. We developed 3-Axis sensor system which is suitable for measuring ride quality of elevator using cheap MEMS sensor. There are two types of MEMS sensor that are piezoresistive and capacitive type. The excellence of piezoresistive type in characteristic of frequency response and noise is confirmed compare to capacitive type as a result of this paper's experiment and reference. 3-Axis system using MEMS sensor needs MEMS's proper frequency response characteristic. Additionally noise characteristic of sensor and circuit, stiffness of assembly are needed for deciding frequency range and accuracy of amplitude.

Wireless structural health monitoring of stay cables under two consecutive typhoons

  • Kim, Jeong-Tae;Huynh, Thanh-Canh;Lee, So-Young
    • Structural Monitoring and Maintenance
    • /
    • 제1권1호
    • /
    • pp.47-67
    • /
    • 2014
  • This study has been motivated to examine the performance of a wireless sensor system under the typhoons as well as to analyze the effect of the typhoons on the bridge's vibration responses and the variation of cable forces. During the long-term field experiment on a real cable-stayed bridge in years 2011-2012, the bridge had experienced two consecutive typhoons, Bolaven and Tembin, and the wireless sensor system had recorded data of wind speeds and vibration responses from a few survived sensor nodes. In this paper, the wireless structural health monitoring of stay cables under the two consecutive typhoons is presented. Firstly, the wireless monitoring system for cable-stayed bridge is described. Multi-scale vibration sensor nodes are utilized to measure both acceleration and PZT dynamic strain from stay cables. Also, cable forces are estimated by a tension force monitoring software based on vibration properties. Secondly, the cable-stayed bridge with the wireless monitoring system is described and its wireless monitoring capacities for deck and cables are evaluated. Finally, the structural health monitoring of stay cables under the attack of the two typhoons is described. Wind-induced deck vibration, cable vibration and cable force variation are examined based on the field measurements in the cable-stayed bridge under the two consecutive typhoons.

회전기기 실시간 동작상태 모니터링을 위한 자가발전 기반 센서모듈 (Self-Powered Integrated Sensor Module for Monitoring the Real-Time Operation of Rotating Devices)

  • 김창일;여서영;박범근;정영훈;백종후
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.311-317
    • /
    • 2019
  • Rotating devices are commonly installed in power plants and factories. This study proposes a self-powered sensor node that is powered by converting the vibration energy of a rotating device into electrical energy. The self-powered sensor consists of a piezoelectric harvester for self-power generation, a rectifier circuit to rectify the AC signal, a sensor unit for measuring the vibration frequency, and a circuit to control the light emitting diode (LED) lighting. The frequency of the vibration source was measured using a piezoelectric-cantilever-type vibration frequency sensor. A green LED was illuminated when the measured frequency was within the normal range. The power generated by the piezoelectric harvester was determined, and the LED operation was assessed in terms of the vibration frequency. The piezoelectric harvester was found to generate a power of 3.061 mW or greater at a vibration acceleration of 1.2 g ($1g=9.8m/s^2$) and vibration frequencies between 117 and 123 Hz. Notably, the power generated was 4.099 mW at 122 Hz. As such, our self-powered sensor node can be used as a module for monitoring rotating devices, because it can convert vibration energy into electrical energy when installed on rotating devices such as air compressors.

광섬유 센서를 이용한 평판의 진동 감지 및 제어 (Vibration Sensing and Control of a Plate Using Optical Fiber Sensor)

  • 김도형;한재흥;양승만;김대현;이인;김천곤;홍창선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.459-464
    • /
    • 2001
  • Vibration control of a plate using an optical fiber sensor and a PZT actuator is considered in this study. An aluminum plate with attached Extrinsic Fabry-Perot Interferometer (EFPI) and PZT actuator is prepared for experimental investigation. Vibration level of EFPI that can represent the mechanical strain without severe distortion is validated by forced vibration experiment. A numerical model of the plate is constructed based on the experimentally obtained frequency responses, and an optimal controller is designed for the multi-modal vibration suppression. It is found that the vibration level of the first three modes can be greatly reduced. The effect of low-pass filtering used to eliminate high frequency noise on the stability and control performance is also considered.

  • PDF

광강도형 광섬유센서를 이용한 피로손상 및 진동감지 (Fatigue Damage Detection and Vibration Sensing Using Intensity-Based Optical Fiber Sensors)

  • 양유창;전호찬;한경섭
    • Composites Research
    • /
    • 제13권1호
    • /
    • pp.89-97
    • /
    • 2000
  • 광섬유센서를 이용한 복합적층판의 피로손상 감지 및 진동측정, 그리고 스틸 보에 대한 충격위치 검출에 관한 연구가 수행되었다. 피로과정중의 신호는 복합재료 내에 삽입된 광섬유와 표면에 부착한 광강도형 광섬유센서, 그리고 스트레인게이지로부터 동시에 측정되었다. 진동감지 실험은 복합재료 보의 표면에 광섬유센서를 부착하여 자유진동 및 강제진동 신호를 취득하였다. 충격위치 검출에 관한 실험에서 충격위치는 충격에 의해 발생된 구조물의 진동이 두 센서에 도달하는 시간의 차를 이용하여 구할 수 있다. 광강도형 광섬유센서를 이용하여 반복 피로 신호를 잘 취득할 수 있었으며 스트레인게이지에 비하여 피로저항성이 우수함이 확인되었다. 광섬유센서는 갭센서와 동일하게 진동신호를 감지하였고 구조물에 가해진 충격위치를 비교적 정확히 검출할 수 있었다.

  • PDF