• 제목/요약/키워드: Vibration Problem

검색결과 1,779건 처리시간 0.024초

부분 구조물 합성으로 이루어진 고유치 문제 해석 (Partitioned structural eigenvalue analysis)

  • 정의일;나혜중;노석홍;전두환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.117-119
    • /
    • 2005
  • For large structural eigen-analysis, the whole structure is divided into some partitioned structures and through synthesis of partitioned structural model the eigen-data of structure can be obtained. In that case, eigenvalue problem consists of semidefinite mass matrix form because of displacement constraint condition. In this work the eigenvalue problem is considered by means of several method, determinant search and null space reduction method.

  • PDF

소각장과 펌프의 이상소음 제어 (A Noise Control of the Incineration Plant and the Pump)

  • 주원호;박진화;배종국;정균양
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.741-746
    • /
    • 1998
  • A severe noise in industrial field can be sometimes generated from unexpected installation error and misunderstanding of industrial machinery. To solve the noise problem, the diagnostic tool is generally applied to identify the noise source and to detect the fault of machinery. And then, the suitable control countermeasure corresponding to the diagnostic results is presented. In this paper, two control cases an noise problem of the Incineration Plant and the Pump are introduced.

  • PDF

샘플 추출방법에 근거한 비선형 진동계의 성능 불확실성 예측 (Performance Uncertainty Estimation of a Nonlinear Vibration System Based on a Sampling Method)

  • 최찬규;유홍희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.113-118
    • /
    • 2009
  • A designer regards the vibration system as a linear system. However, in real world, nonlinearity of a vibration system should exist caused by various factors like manufacturing conditions or uncertain material properties. So, properties of a spring and a damper which are consisting the vibration system have statistical distribution. Therefore, a designer needs to analyze the statistical nonlinearity in a vibration system. In this paper, $1^{st}$ Taylor series expansion method and univariate dimension reduction method apply to a performance measure of nonlinear vibration system, and compare each result. And then, merits and demerits of each method are discussed. For apply more actual problem, a performance measure population is estimated based on design variable samples like properties of spring or damper.

  • PDF

정밀장비의 방진 및 과도응답 제어를 위한 하이브리드 방진시스템 (The Hybrid Control System for the Vibration Isolation and the Transient Response Reduction of precision Equipment)

  • 이규섭;손성완;이홍기;한현희;전종균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.185-189
    • /
    • 2009
  • It is very important to control the vibration transmitted from external utilities and the transient response due to the internal sources for the precision equipment, which is very sensitive to the vibration environment. The anti-vibration tables that use air springs have been widely used due to their excellent isolation performance, but the systems with high flexibility have the critical problem of large transient response by the impulsive force of the moving mass in operation of the equipment. In this paper, the hybrid vibration control system is proposed, which is combined the air springs with the semi-active MR dampers in order to satisfy the performances of isolation and vibration reduction simutaneously.

  • PDF

주행중 가속페달의 급조작시 승용차의 진동특성 해석 (An Analysis on the Vibration Characteristic of a Automobile at the Sudden Change of an Accelerator under Traveling)

  • 홍동표;정태진;김상수;태신호
    • 소음진동
    • /
    • 제4권3호
    • /
    • pp.353-363
    • /
    • 1994
  • The non-preiodic fluctuation of the engine torque appears to be the major source of the torsional vibration of the automotive driveline. The reduction of this torsional vibration hs become a significant problem along with the requirements of higher performance. The shuffle(tip-in, tip-out) is the transient vibration phenomenon of a vehicle which appears at the sudden change of an accelerator under traveling. By executing of an experiment and a simulation using a model, it has become possible to obtain the design parameter of a driveline for the torsional vibration. This paper presents an experimental and theoretical research on the transient vibration phenomenon of a vehicle which appears at the sudden change of an accelerator under traveling. A dynamic model for the automotive driveline was developed, and all parameters of the mmdel were evaluated with experimental data. The results are as follows: (1) The lower the gea ratio of the transmission is, the more the transient vibration phenomenon of a vehicle appears clearly. (2) The transient vibration phenomenon of a vehicle is affected by the design parmeter of the driveline.

  • PDF

복합 화력 Condensate Pump 의 고진동 사례 분석 및 대책 (A Case Study on High Vibration in a Condensate Pump for Combined Cycle Power Plants)

  • 최성필;류석주;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.510-513
    • /
    • 2001
  • Several kinds of vibration problems have been frequently encountered in industrial vertical pumps in spite of their widespread use for long time. In fact, vibration problems of the vertical pumps are so complicated and difficult with compared to those of the horizontally mounted pumps that more careful attention should be taken for solving the vibration problems. This paper introduces a case study experienced from troubleshooting for excessive vibration occurred in a vertical-type condensate pump for combined cycle power plants. Subsynchronous whirl vibration was caused by the instability of the guide bearing whose lubricant is water. A newly modified guide bearing has solved the vibration problem, which should be the best countermeasure.

  • PDF

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 간헐적 고진동 현상 규명 (Examination of the Intermittent High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.190-195
    • /
    • 2002
  • The intermittent high vibration has been occurred one or two times a day for a 500MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the intermittent high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

  • PDF

펄세이터형 세탁 시스템의 진동 해석 (Vibration Analysis of a Pulsator type Washing System)

  • 이신영;강주석;윤중락;이장무;윤구영;김남권
    • 소음진동
    • /
    • 제7권2호
    • /
    • pp.261-272
    • /
    • 1997
  • Recently washing machines are to be in lower vibration and lower sound because of better environment. Vibration problems in washing machines occur in both washing mode and spinning mode, but vibration in spinning mode becomes main problem because of its high rotating speed and continuity. Vibration while spinning is mainly due to rigid body motion of total washing system which includes suspending rods, washing bath, spinning bath, and gear sets. In this study, some researches were done in order to analyze the rigid body motion of washing system and flexible vibration of spinning bath. A basic mathematical model was established, and the effect of position of salt water and shape change of salt water case were considered. And the effect of lengths of suspending rods, attaching angles, vertical and horizontal position, stiffness of spring on the change of vibration were also considered. To identify the effect of salt water on vibration, some measurements were done. When salt water was positioned at upper part, the effect was most and this coincides with the tendency of simulation.

  • PDF

단축가진 시험을 통한 진동내구 손상도 계산 (Verification on Damage Calculating Method of Vibration Fatigue Using Uni-axial Vibration Test)

  • 김찬중;배철용;이봉현
    • 한국소음진동공학회논문집
    • /
    • 제16권5호
    • /
    • pp.521-528
    • /
    • 2006
  • The vibration fatigue is suitable case of fatigue problem that system is exposed to the random or other irregular sources. Even some kinds of effort using power spectral density (PSD) and statistical concept was presented to cope with the intangible force signal, it is still lack of providing a reasonable solution when its exciting frequency is near or beyond of first eigenvalue. In this paper, energy approach method is presented to calculate a vibration induced fatigue damage in frequency domain. Since the corresponding damage become much larger than nominal case when the vibration is coupled with a mode shape of given structure, the new technique compensate the characteristics of structure with a measured frequency response function (FRF) between forcing acceleration and responding stress.

국내 철도차량 감속기 진동특성분석 (Vibration Characteristics Analysis of Reduction Unit for Railway Vehicles)

  • 지해영;김재철;이동형;문경호;이강호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.169-174
    • /
    • 2012
  • Reduction unit is one of the most important components for railway vehicle because torque of motor must be transmitted to wheels of vehicle by reduction unit. However, According to advanced studies, it has been often broke down due to the damage, fatigue and wear of gear. To solve this problem, defect diagnosis methods of gear have been mainly using the vibration diagnosis technology through vibration waveform and frequency analysis. However, We should know vibration characteristics of normal state reduction unit prior to defect diagnosis. So in this paper, We had analyzed vibration characteristics of reduction unit in order to utilize monitoring system development. Comparison of targets is the vibration characteristics of normal state reduction unit about Electric Multiple Unit(EMU) and the High-speed trains(KTX, KTX II).

  • PDF