• 제목/요약/키워드: Vibration Limits

검색결과 187건 처리시간 0.027초

힘제한 방법을 이용한 소형 위성의 진동시험 (Force Limited Vibration Tests of Micro-Satellites)

  • 김영기;김홍배;김경운;우성현;김성훈;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.446-451
    • /
    • 2004
  • Over testing problems of satellites and theirs components have been issued due to their effects on satellite development cost and schedule. Force limited vibration tests were introduced as solution of the problems in 1980s. Over testing phenomena occurs due to the lack of similarity on interface impedance. Force limited vibration tests control interface force to simulate actual interface impedance. In this research, force limited vibration tests are applied on two satellites environmental tests. Force limits are calculated by using TDFS method and Semi-Empirical method. Four force sensors are employed to control interface force. The tests prove that force limited control reduced maximum interface acceleration in order of 3.

  • PDF

전동-발전기의 방진 마운트에 기인한 공진현상 및 동특성 규명 (Dynamic characteristic for vibration mount of MG-Set)

  • 유무상;오경환;주인국;김효진;노철우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.816-821
    • /
    • 2013
  • This case study presents a practical method to reduce resonant vibration of generator-motor set. The generator is driven at 1800rpm by induction integral motor. The vibration is below alarm limits, but the dominant frequency of vibration is sub-synchronous and close to that of bearing fault signal in spite of new bearings. To find an mechanism of abnormal vibration, ODS and Modal analysis is carried out. The measured modal characteristics were compared with those of FE Analysis. The ODS mode at rated speed is consistent with system natural frequency mode that is excited by bearings. To reduce vibration level, the isolation mount at system base is changed with new rubber mount for lower natural frequency.

  • PDF

청감실험을 통한 도로교통소음에 대한 공동주택 내부소음 기준설정 연구 (Indoor Noise limits of Apartment Houses for Road Traffic Noise by Psycho-acoustic Experiment)

  • 이주엽;김항;송민정;장길수;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.83-86
    • /
    • 2005
  • The aim of this study is to establish the indoor noise limits of apartment houses for mad traffic noise. To achieve this goal, psycho-acoustic experiments were carried out with the mad traffic sound sources modulated by the transmission loss characteristics of the external windows. As a result of this study, followings are suggested. 1) On correlation between dose level and psycho-acoustical response, the initial level of negative feeling is located on $40.1{\sim}40.6$ Leq dB(A). 2) On the degree of satisfaction to road traffic noise, near 35% Point being same dissatisfaction degree is to be assumed $40{\sim}41$ dB(A) of indoor noise level presented into three vocabulary. It is suggested to be reasonable level of 40 dB(A) on the indoor noise limits for intruding road traffic noise, and it is appropriate to be the 5dB level difference between grades.

  • PDF

Developments in composite construction and cellular beams

  • Lawson, R.M.;Hicks, S.J.
    • Steel and Composite Structures
    • /
    • 제5권2_3호
    • /
    • pp.193-202
    • /
    • 2005
  • This paper describes recent developments in composite construction and their effect on codified design procedures in the UK. Areas of particular interest include: rules on shear connection, design of beams with web openings, serviceability limits, such as floor vibrations, and fire safe design. The design of cellular beams with regular circular openings now includes generalized rules for web-post buckling, and for the development of in-plane moment in the web-post for asymmetric sections. Closed solutions for the maximum shear force due to limits on web-post bending or buckling are presented. The fire resistance of cellular beams is also dependent on the temperature of the web-post, and for closely spaced openings. It is necessary to increase the thickness of fire protection to the web. For serviceability design of beams, deflection limits and natural frequency and response factor for vibration are presented. It may be necessary to use stricter limits for certain applications.

선진국과 한국의 소음저감정책 비교 (Comparison of Noise Abatement Policies in Advanced Countries and Korea)

  • 강대준
    • 한국소음진동공학회논문집
    • /
    • 제21권12호
    • /
    • pp.1177-1184
    • /
    • 2011
  • One of the main objectives of noise control act is to define and ensure application and respect of noise exposure limits. Most advanced countries have prepared a legal framework for noise limits either by national laws, ordinances or municipal by-laws. A large number of advaced countries have adopted the Leq index for the main sources of noise(road, railway, industry). The exception is aircraft noise for which regulatory practice is highly disparate. These differences in the indices adopted, the periods and areas to which regulations apply, definitions of measurement conditions and ways in which noise levels are calculated make it difficult to compare the current advanced countries standards. This study presents the current noise abatement policy of the advanced countries and proposes the improvement of the current noise abatement policy of Korea to catch up with it of the advanced countries.

김포공항 항공기 저소음 운항절차 수립을 위한 연구 (A Study on the Establishments of Aircraft Noise Abatement Procedures in Gimpo International Airport)

  • 손정곤;김연명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1033-1037
    • /
    • 2007
  • The final purpose of this study is to develop noise abatement procedures for minimizing the environmental impacts caused by aircraft noise in the vicinity of Gimpo Int'l Airport, and to establish appropriate noise limits and monitoring system. The results of study was suggests for more detail the crucial factors which one is reference noise level, $L_{MAX}=88dB(A)$ at 6.5km after take-off, and second one is to installation the additional three(3) noise monitoring system on both side of runway.

  • PDF

김포공항 항공기 저소음 운항절차 수립을 위한 연구(II) (A Study on the Establishments of Aircraft Noise Abatement Procedures in Gimpo International Airport)

  • 손정곤;김연명
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.874-880
    • /
    • 2007
  • The final purpose of this study is to develop noise abatement procedures for minimizing the environmental impacts caused by aircraft noise in the vicinity of Gimpo Int'l Airport, and to establish appropriate noise limits and monitoring system. The results of study was suggests for more detail the crucial factors which one is reference noise level, $L_{MAX}=88 dB(A)$ at 6.5 km after take-off, and second one is to installation the additional three(3) noise monitoring system on both side of runway.

선진국과 한국의 소음저감정책 비교 (Comparison of Noise Abatement Policies in Advanced Countries and Korea)

  • 강대준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.558-567
    • /
    • 2011
  • One of the main objectives of noise control act is to define and ensure application and respect of noise exposure limits. Most advanced countries have prepared a legal framework for noise limits either by national laws, ordinances or municipal by-laws. A large number of advaced countries have adopted the $L_{eq}$ index for the main sources of noise (road, railway, industry). The exception is aircraft noise for which regulatory practice is highly disparate. These differences in the indices adopted, the periods and areas to which regulations apply, definitions of measurement conditions and ways in which noise levels are calculated make it difficult to compare the current advanced countries standards. This study presents the current noise abatement policy of the advanced countries and proposes the improvement of the current noise abatement policy of Korea to catch up with it of the advanced countries.

  • PDF

4,500 TEU 컨테이너 운반선의 소음 제어 (Noise Control for 4,500 TED Container Carrier)

  • 김동해;임도형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1313-1316
    • /
    • 2001
  • Generally, container carrier has larger engine than other commercial vessels and the engine casing is located in accommodation space. Therefore, the noise levels of cabins and engine room could be exceeded the specified noise limits and might be an annoyance to crews, and which can result in poor ship quality. Main subject of this study is to predict noise levels of the 4,500 TED container carrier by statistical energy analysis method in order to comply with contracted noise limits and to compare with the measured values. Additionally, through the contribution analysis of noise sources to each cabins, and appropriate countermeasures are proposed and the reduction effect of each noise control measure is studied by the analysis method. This study will contribute to reduce the noise levels of similar vessel.

  • PDF

인체진동 측정 및 분석체계 (Measurement and Analysis of Human Vibration)

  • 박희석;장동성
    • 대한인간공학회지
    • /
    • 제18권3호
    • /
    • pp.179-186
    • /
    • 1999
  • This article aims to provide information necessary for the measurement and analysis of human vibration, especially hand-arm vibration. The major health problems associated with the use of powered hand tools are the signs and symptoms of peripheral vascular and peripheral neural disorders of the fingers and hands. To prevent these problems, it is the first and the most important to measure the amount of the vibration transmitted to the upper extremities, and analyze its characteristics against the exposure limits such as ISO standards. In our country, however, very few studies have been done on the hand-arm vibration. One of the possible reasons might be lack of knowledge for the measurement and analysis schemes. The information introduced in this article would hopefully be of help for the upcoming studies.

  • PDF