전단벽식 건축구조물 수직진동의 수평방향 전달특성에 관한 실험연구 (An Experimental Study on the Vertical Vibration Transfer in Horizontal Way according to Shear Wall Building Structures due to Exciting Vibration Forces)

  • 전호민
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.270-282
    • /
    • 2006
  • In general, the vertical vibration problems for strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions to near-rooms on the shear wall building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on two building structure. The results from the experiments are analyzed and compared with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs, and are effected the shear wall on the Path of the vibration transfer.

환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험 (Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor)

  • 이강희;김대호;전태현;김형규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

가속도계와 동적신호분석기를 이용한 건축물 바닥슬래브 동특성 및 수직진동 전달특성 측정 (Measurements on the Characteristics of Dynamic and Vertical Vibration Transfer according to floors of Building Structures using Accelerometer and Dynamic signal analyzer)

  • 전호민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.29-34
    • /
    • 2006
  • In general, the vertical vibration problems for .strength of members and serviceability of building structures are not considered in structural design process, but the prediction of the vertical vibration is very important and essential to structural design process. This study aims to investigate the characteristics of vertical vibration in terms of the transfer of horizontal directions on the rahmen building structures. In order to examine the characteristics of vertical vibration, the modal test and the impact (heel-drop and hammer) excitation experiments were conducted several times on three building structures. The results from the experiments are analyzed and compared. with the results. The results of this study suggest that the characteristics of vertical vibration transfer in horizontal way are effected from the fundamental frequency of the slabs and excitation forces.

  • PDF

전동차 바닥구조의 진동절연특성이 실내소음에 미치는 영향 (Study on the Effect of Vibration Reduction Characteristics of Floors on the Inside Running Noise in Railway Vehicles)

  • 우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.908-912
    • /
    • 2008
  • Structure-borne noise is known to dominate internal running noise levels in open field. In this paper vibration isolation characteristics of floors are investigated to see their effect on the internal running noise. By using the analysis and test results of test specimen of small size, internal running noise level of complete train is estimated. Analysis results show that soft rubber as a vibration isolator has the most favorable effect on the inside running noise.

  • PDF

항공용 마운트의 개발과 시뮬레이션 (The Development & Simulation for the Isolation Mount installed in Aircraft)

  • 전희호;박재민;이승준
    • 한국소음진동공학회논문집
    • /
    • 제20권3호
    • /
    • pp.223-228
    • /
    • 2010
  • The mount which is used in military airplane should be operated in various situations such as vibration, shock and temperature. The recent mounts cost a lot and take much time to replace when they broke down. That's why new mount was produced in domestic by reverse engineering and the product has been proved its performance through environment test regarding vibration and shock. According to simulation of dynamic characteristics on vibration and shock, the result turns out to be similar to the result of the environmental test with an error of within 10 percent. As a result this research, a draft of the military aviation mount designing program is arranged.

점탄성물질 난류댐퍼를 이용한 K형 철골 브레이스 골조의 진동응답해석 (A Vibration Response Analysis of Steel Building Frame with K Shape Brace Vibrationally Controlled by Turbulent Flow Dampers sealed by Visco-elastic Material)

  • 이호
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.61-68
    • /
    • 2006
  • 본 논문에서는 패시브 진돈제어시스템을 설치한 실대물 K형 철골브레이스 골조의 실험결과를 다루었다. 패시브 진동제어시스템은 점탄성물질을 이용하여 새롭게 개발된 댐퍼를 사용하였다. 이 실험모델의 진동제어 효율성을 확인하고 철골조 브레이싱의 진동반응특성을 조사하기 위하여 일련의 실험을 행하였다. 자유진동실험결과 댐퍼를 설치시 설치하지 않은 경우와 비교하여 3배정도의 진동제어능력을 나타냈다. 점탄성물질 난류댐퍼의 효율성은 진동실험에 의하여 확인되었다.

  • PDF

기어 손상에 따른 진동 상태표시기 특성 평가 (Characteristics of Vibration Condition Indicator with Gear Tooth Damage)

  • 이동형;이웅용;문경호
    • 한국정밀공학회지
    • /
    • 제32권7호
    • /
    • pp.611-617
    • /
    • 2015
  • In the development of a vibration-based condition monitoring system in gearbox, one of the most important research topics is a quantitative analysis and test of the effect of gear damage on vibration of gearbox. This paper presents the evaluation result of vibration condition indicator according to the gear tooth damage through the vibration test of gearbox. The dynamic load test was performed with high speed railway (KTX)'s gearbox. The vibration of gearbox was measured according to a rotational speed change with the common gear fault modes, such as pitting and tooth breakage. The characteristics and the possibility of applying of vibration condition indicator on condition monitoring system were analyzed. As a result, the value of most condition indicator is gradually increased with the severity of gear faults. The NA6 indicator shows a low variation with the rotational speed change and high sensitivity in accordance with the gear fault.

수직발사 유도탄의 진동시험에서 유도탄 장착방향의 영향에 대한 연구 (Study on the Effects of the Mounting Direction of Vertically-launched Missiles in Vibration Tests)

  • 이호준;김기언
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.218-225
    • /
    • 2013
  • Vertically-launched missiles are supported as erected vertically in the vertical launching system of warship, and they should be mounted in the same way when vibration-tested. However, mounting missiles vertically makes a fixture, which is a supporting structure, bulky and heavy so requiring a high-performance exciter. Mounting missiles as laid down horizontally in a vibration test is economical regarding fixture manufacturing and exciter performance, but it makes test results incorrect because the different mounting direction has effects on the test results. A bending moment due to missiles' weight happens to missiles, and resilient mounts, which support missiles in the vertical launch system, deflect differently from the real situation because of the static deflection of these mounts due to missiles' weight. If the resilient mounts supporting missiles have nonlinear force-deflection characteristics, vibration test results become more different from the true results. This paper proposes to support missiles with an additional resilient mount such as a bunge code in order to solve those problems coming from mounting vertically-launched missiles as laid down horizontally in vibration tests. The proposed approach enables to obtain the same test results as in their actual mounting condition even though vertically-launched missiles are mounted in a different direction.

동경방향 스펙클 전단 간섭계를 이용한 대칭형 물체의 진동 모드 특성에 관한 연구 (A study on characteristics of mode shapes of symmetrical objects using radial Electronic Shearograhpy)

  • 최장섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.319-324
    • /
    • 1996
  • In this paper, radial sheared eletronic shearopgraphy was studied in order to measure vibration characteristics of circular or radial symmetric objects. We calculated amplitude of vibration by using eletro-optic holography theory, and utilized a porror prism for optical arrangement of sheared two images in this experiment. In this case, the data measured by shearing interferometer give us a distribution of the gradient of vibration amplitude. This developed system is applied to symmetical objects such as fans of airconditioner and circular plates to test vibration characteristics.

  • PDF

축방향 유속에 노출된 $5{\times}5$ 지지격자 스트랩의 진동특성 (The Strap Vibration Characteristics in $5{\times}5$ Grid Exposed to Axial Flow)

  • 김경홍;박남규;김경주;서정민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.911-916
    • /
    • 2012
  • It is important to identify dynamic characteristics of nuclear fuel components. Since the fuel always exposed to turbulent flow, the dynamic contact between grids and rods is one of the fuel failure modes. The dynamic behavior of grids in nuclear fuels is quite complex, since two pairs of spring support are placed in the limited space. The strap in a cell has single spring and double dimples and this paper focuses on investigation of the grid strap(Test Fuel Strap, TFS) vibration in one cell. To identify the grid strap vibration, modal analysis of the strap is performed using Finite Element Method (FEM). Modal testing on a $5{\times}5$ grid structure without rods is performed. The modal testing results are compared to analytic results. In addition, random test considering rod effect is performed about a $5{\times}5$ grid with rods under real contact condition in the air. Finally, the strap vibration of a $5{\times}5$ fuel bundle in INvestigation of Flow INduced vIbraTion(INFINIT) facility is measured in real fluid velocity condition without heating. It is shown that modal frequencies from the test are almost equal to those peak frequencies in the INFINIT test.

  • PDF