공동주택에서의 화재 경보음 전달특성에 관한 연구 (An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings)

  • 이민주;김명준;윤명오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

공동주택 화재 경보음 전달특성과 개선방안 고찰 (An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings)

  • 이민주;윤명오;김명준
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

공동주택 화재경보 발생음 특성에 관한 실험연구 (Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings)

  • 이민주;강희혁;권봉석;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

휴대용 메모리형 방사선 경보장치 개발 (Development of Portable Memory Type Radiation Alarm Monitor)

  • 손중권;이명찬;송명재
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.263-272
    • /
    • 1997
  • 방사선 작업자의 과피폭을 방지하기 위해 방사선 작업 도중 이상 사태가 발생할 경우 광 음경보가 발생한 후 이상 사태 발생 90분, 발생 30분간의 방사선량과 방사선량율 변화를 저장하고 외부 PC로 데이터를 전송한 후 사고를 분석하여 차후에 같은 유형의 방사선 사고를 사전에 예방할 수 있도록 고안된 방사선 경보장치를 개발하였다. 이 방사선 경보장치의 특징은 넓은 방사선 측정 범위(10mR/h $\sim$ 100 R/h), 방사선 준위의 기록 및 기억, PC와의 data처리 기능, 휴대성, 교정 기능에 의한 높은 정밀도(${\pm}5%$), 인지도가 높은 강력한 경보기능 채택 등이다. 개발된 방사선 경보장치의 물리적 환경 적응시험을 가장 엄격한 ANSI N42.17A의 표준 시험조건에 의거하여 온도, 습도, 진동, 전자기파 간섭 등에 관해 한국표준과학연구원에서 수행하였으며 모든 시험항목을 통과하였다.

  • PDF

LPMS 신호분석 연구 (A Study on the Signal Analysis of Loose Parts Monitoring System)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.839-841
    • /
    • 2014
  • The Nuclear Steam Supply System(NSSS) is designed to provide an integrated approach that includes areas of monitoring relevant to the integrity of the NSSS. LPMS is designed to function as an alarm system by providing sensor channel alarms for the associated subsystems. LPMS is equipped to provide analysis tools for new alarm events, historical events and for historical periodically stored channel data (e.g. waveforms) for most channels. This paper is intended to introduce the diagnosis principle and abnormal symptom of loose parts monitoring system as a monitoring tool in Nuclear Steam Supply System. And also, we are going to introduce signal analysis program in order to perform the actual diagnosis in power plants.

  • PDF

시각장애인을 위한 색상판별 진동알림 시스템 (Color Sensing Vibration Alarm System for People with Visually Impaired)

  • 송은지;황연수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.664-665
    • /
    • 2015
  • 최근 IT기술이 점점 발달함에 따라 장애인의 일상생활을 편리하게 하는 도구들이 속속 개발되고 있다. 본 연구에서는 시각장애인들이 색상판별을 진동을 통해 감지할 수 있는 시스템을 개발하였다. 이것은 최근 대중화되고 있는 사물인터넷(IoT)의 기반이 되는 아두이노 기술을 접목하여 다양한 스위치와 센서로 입력 값을 받아들여 LED, 모터와 같은 외부출력장치를 제어함으로써 상호 작용을 만들어 낼 수 있는 시스템이다. 구체적으로 제안하는 시스템은 컬러센서를 통해 색상을 감지하고 색상 값을 수치 값으로 읽어 들이고 수치 값에 진동의 세기 주기 등을 달리함으로 시각장애인이 색상을 판별할 수 있도록 되어있다.