Natural Free Convection of Air in a Vertical Open Tube With Uniform Heat Flux and Temperature (일정 열류속 및 온도조건하의 수직관내에서 공기의 자연대류 열전달 연구)

  • Son, Byung-Jin;Kang, Hee-Yung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.234-239
    • /
    • 1983
  • The natural free convection in a vertical tube with uniform heat flux and temperature has been studied by the theoretical analysis is of governing equations and experimental measurements. In order to determine the Characteristics of Convective heat transfer in the tube, a dimensionless Rayleigh number is introduced. The relationship between Nusselt and Rayleigh number is compared with the numerical analysis of finite difference method and experiment. Nusselt number obtained from the experimental measurements are in a good agreement with the calculated values, and the relationship equations between Nusselt and Rayleigh number are obtained.

  • PDF

A Study on Bubbly Flow using PIV Measurement (PIV 법을 이용한 기포유동에 관한 연구)

  • 배대석;권오봉
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.898-903
    • /
    • 2001
  • The particle image velocimetry with liquid crystal tracers is used for visualizing and analysis of the bubbly flow in a vertical temperature gradient. This method allows simultaneous measurement of velocity and temperature field at a given instant of time Quantitative data of velocity were obtained by applying the MQD technique to visualized image. The paper describes the method, and presents the transient velocity patterns of bubbly flow.

  • PDF

Automatic Control System of Vertical Agitation Heater for Controlling Temperature of Greenhouse (시설하우스 온도 조절을 위한 수직형 교반 히터 자동제어 시스템)

  • Kwak, Yun-Ah;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.623-628
    • /
    • 2015
  • As the current heating control of the greenhouse is located in specifically designed place, there is an inevitable difference in degrees depending on the latitude in it. Even though it is necessary to maintain the proper temperature in the greenhouse producing vegetables and fruit plants, the difference between ups and downs in the facilities results in the increasing energy consumption to both warm and cool down the facilities. The newest heating method, automatic control system of vertical agitation heater, which manipulates the inner air circulation efficiently, is suggested in this paper. The proposed system utilizes both the upper temperature and the lower temperature, and controls the air circulation fan and heating independently, so that maximizes the efficiency of heating with the minimum energy and implements predictable planning of farm products.

Relationship between Migratory Timing of Salmon (Oncorhynchus keta) into the Wangpi River and Coastal Environment of the Mid-eastern Coastal Water of Korea (동해 중부 연안에서 연어(Oncorhynchus keta)가 왕피천으로 이동하는 시기와 연안 환경간의 관계)

  • Kim, Beom-Sik;Jung, Yong-Woo;Jung, Hae-Kun;Lee, Chung Il
    • Journal of Environmental Science International
    • /
    • v.30 no.12
    • /
    • pp.1067-1079
    • /
    • 2021
  • The coastal water is a space where salmon (Oncorhynchus keta), critical energy-conveying mediator, stay to adapt to different environments while traveling between ocean and river ecosystems for spawning and growth. The mid-eastern coast of Korea (MECW) is the southern limit of salmon distributed in the North Pacific Ocean. Understanding the distribution and migration characteristics of salmon in the MECW is important for the prediction of changes in the amount and distribution of salmon related to changes in the future marine environment. We analyzed the relationship between the salmon migratory timing ascending the Wangpi river and change in vertical seawater temperature and tidal elevation. Overall results highlight that (1) Salmon began to ascend the river when the sea surface water temperature (SST) decreased below 20℃; (2) The number of salmon ascending the river increased when the temperature difference between the upper and lower layers decreased, but decreased when the temperature difference was higher than 5℃; (3) The number of salmon ascending the river peaked, when the SST was 18℃-19℃ and sea levels rose at high tide. This study provide important insight into predicting changes in the ecosystem energy circulation through climate change at its southern distribution limit.

A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA (열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구)

  • Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process (반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향)

  • Park, Jun-Su;Kwon, Hyun-Goo;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

Study of the Effects of Ambient Temperature and Car Heater Power on the Train Cabin Temperature (외기 온도와 난방 출력의 철도차량 객실 온도에 대한 영향 연구)

  • Cho, Youngmin;Park, Duck-Shin;Kwon, Soon-Bark;Jung, Woo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5877-5884
    • /
    • 2014
  • Recently, abnormally cold weather has been reported more frequently in winter due to the climate change and abnormal weather changes. On the other hand, the heating capacity of a railcar may be not enough to warm the cabin under severe cold climatic conditions, which is one of the reasons for the passengers' complaints about heating. In this study, the effects of ambient temperature and heater power on the cabin temperature was investigated to obtain the minimum ambient temperature for the tested railcar. The test railcar was placed in a large-climatic chamber, and various ambient temperature conditions were simulated. The effects of the heater output were investigated by monitoring the cabin temperature under a range of heater output conditions. The mean cabin temperature was $14.0^{\circ}C$, which was far lower than the required minimum temperature of $18^{\circ}C$, under a $-10^{\circ}C$ ambient temperature condition with the maximum heat power. When the ambient temperature was set to $0^{\circ}C$ and $10^{\circ}C$, the maximum achievable cabin temperature was $26.1^{\circ}C$ and $34.0^{\circ}C$. Through calculations using the interpolation method, the minimum ambient temperature to maintain an $18^{\circ}C$ cabin temperature was $-6.7^{\circ}C$ for this car. The vertical temperature difference was higher with a higher power output and higher ambient temperature. The maximum vertical temperature difference was higher than $10^{\circ}C$ in some cases. However, the horizontal temperature difference vs. low temperature (< $2^{\circ}C$) was independent of the power output and ambient temperature. As a result, it is very important to reduce the vertical temperature difference to achieve good heating performance.

Evaluation of Atmospheric Stability Classification Methods for Practical Use (대기안정도 분류방법의 평가 및 실용화에 관한 연구)

  • 김정수;최덕일;최기덕;박일수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.369-376
    • /
    • 1996
  • Major atmospheric stability classification methods were evaluated with meteorological data obtained by scoustic sounding profiler (SODAR/RASS) in Seoul. The Psequill classificatio method, the method most widely used because of its good agreement in respect of synoptic scope under the steady state, fails to describe the time lag, the response time on stability by heating or cooling caused by daily insolation or noctrunal surface radiation. Horizontal and vertical standard deviation of wind fluctuation $(\sigma_A and \sigma_E)$ method tend to classify night-time stable condition (E, F class) into unstable condition (A, B class). The classification matrix tables for Vogt's vertical temperature difference and wind speed using method ($\Delta$T $\cdot$ U) and bulk Richardson number (Rb) were amended for practical use over Seoul. The modified tables for $\Delta$T $\cdot$ U and Rb method were made by using comprehensive frequency distribution from Pasquill's method and other existing results, and the correlation coefficient(r) was equal to 0.829. It was confirmed that atmospheric stability could be changed with monitoring site characteristics, height and vertical difference between sensors of monitoring station, and classification method itself.

  • PDF

A Quantitative Study on the Effect of Temperature Control by a Shade Tree and the Lawn Area (식물의 온도 완화효과에 관한 기초적 연구)

  • 안계복;김기선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study is to investigate the effect of temperature control by a shade tree and the lawn area. In this investigation, we find out that artificial-lawn, concerte, and exposed soil are more higher temperature than covered with plant materials. The results of the measurement may to summerized as follows; 1) Low-temperature effects of zoysia japonica is more controlled by condition of growth than leaf length of grass. Surface temperature make 0.7$^{\circ}C$ difference between long grass (15cm), and short grass (5cm), but make 5$^{\circ}C$ difference between good growth grass (230/10$\textrm{cm}^2$) and bad growth grass (80/10$\textrm{cm}^2$). 2) The surface temperature of the lawn area is 40.5$^{\circ}C$ lower on a maxinum than that of the artificial lawn (July 28, 1985). During the day of summer, shade area under the shade tree is 0.9$^{\circ}C$ lower then lawn area surface temperature, 6.9$^{\circ}C$ lower than bad growth lawn, 10.3$^{\circ}C$ lower than exposed soil, and 18$^{\circ}C$ lower than concrete surface temperature. 3) Natural irrigation effect on the surface temperature fluctuation. But this effect is changed by compositions of ground materials and time-lapse. 4) Sunny day is more effective than cloud day. 5) In summer season, surface temperature make a difference compare to temperature of 0.5-1.5m height from ground : Surface temperature is 3.4$^{\circ}C$ lower at the lawn area (11 a.m.), 4.2$^{\circ}C$ lower at the shade area the shade tree, 12.7$^{\circ}C$ higher at the concrete area (3p.m.), 38.8$^{\circ}C$ higher at the artificial lawn (2p.m.) 6) According to compositions of ground materials and season have specific vertical temperature distribution curve. 7) In summer season, temperature distribution of 0.5-1.5m hight at the shade tree is 4.8-5.7$^{\circ}C$ lower than concrete area (noon-3p.m.)

  • PDF

Development of Algorithms for Extracting Thermocline Parameters in the South Sea of Korea (한국 남부해역의 수온약층 추출 알고리즘 개발)

  • Yoon, Dong-Young;Choi, Hyun-Woo
    • Ocean and Polar Research
    • /
    • v.34 no.2
    • /
    • pp.265-273
    • /
    • 2012
  • A new algorithm was developed, not only to detect the existence of a thermocline, but also to extract the thermocline parameters (such as thermocline thickness, mixed layer thickness, maximum temperature gradient, and temperature difference of thermocline), using the vertical profile of water temperature. According to Kappa analysis, in order to find adequate threshold values of vertical water temperature gradients ${\Delta}T$ ($^{\circ}C/m$), agreement and reliability were 87% and 0.74 respectively, in the conditions of maximum ${\Delta}T{\geq}0.5$ and surface and bottom layers ${\Delta}T<{\mid}0.2{\mid}$. Also, three different kinds of methods, viz. 1. Gradient method, 2. Hyperbolic tangent method, and 3. Differential hyperbolic tangent method, were tested to extract the key parameters of a thermocline. Comparing the results of three different methods, the differential hyperbolic tangent method was the most appropriate to extract the start and end point of a thermocline curve.