• 제목/요약/키워드: Vertical pipe flow

검색결과 102건 처리시간 0.031초

전단박화유체의 수직상향 난류유동시 저항감소에 관한 연구 (A Study on the Drag Reduction of Shear Thinning Fluid with Vertical upward Turbulent Flow)

  • 차경옥;김봉각;김재근
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1647-1656
    • /
    • 1998
  • The drag reduction is the phenomenon that occurs only when the shear stress from the wall of pipe is beyond the critical point. The drag reduction increase as the molecular weight, concentration of the polymer and Reynolds number increase, but it is limited by Virk's maximum drag reduction asymptote. Because of the strong shear force for the polymer on the turbulent flow, the molecular weight and the drag reduction do not decrease. Such mechanical degradation of the polymer occurs in all polymer solvent systems. This paper is to identify and develop high performance polymer additives for fluid transportations with the benefits of turbulent drag reduction. In addition, drag reduction in vertical flow by measuring the pressure drop and local void fraction on vertical-up flow of close system is evaluated.

파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가 (Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop)

  • 길후정;이강자;이철호;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

다양한 배관 경사각도 및 중력조건에서의 층상류 유동양식 예측 (The Prediction of Stratified Flow Pattern in a Variable Tube Inclinations and Gravity Conditions)

  • 최부홍
    • 해양환경안전학회지
    • /
    • 제14권4호
    • /
    • pp.339-345
    • /
    • 2008
  • 기름과 가스 수송 라인 및 선박 내에 설비된 유체 기계들에 관련된 파이프 내에 층상류 흐름이 존재할 수 있다. 이 때문에 수평 혹은 작은 경사 파이프 내에 발생할 수 있는 층상류 흐름을 예측하기 위한 많은 이론과 상관식이 제시되었다. 기존 연구들은 각 상의 물성, 점성, 밀도 및 파이프의 기하학적 형상 등이 층상류 흐름에 주는 효과에 관한 것이 대부분이고, 중력의 크기 및 파이프의 큰 경사 기울기에 관한 연구성과는 매우 드문 실정이다. 따라서 본 연구에는 중력크기 및 파이프 경사도 변화가 층상류 발생 조건에 미치는 영향에 대해 이론적 연구가 수행되었다. 또한 본 해석을 통하여 0.17g 및 0.33g 조건에서는 비록 수직상향 흐름일지라도 매우 낮은 액체상의 유량조건에서는 층상류 흐름이 존재할 수 있음을 알 수 있었다.

  • PDF

플라즈마 아크 오비탈 용접의 경사상진자세에서 이면비드 형성에 관한 연구 (A Study on Back Bead Formation in Inclined-up Position of Flasma An Orbital Welding)

  • 김효원;조상명
    • Journal of Welding and Joining
    • /
    • 제27권1호
    • /
    • pp.71-78
    • /
    • 2009
  • In the circumferential welding of pipe, welding phenomenon changes with the position of pipe. Especially in the overhead position, back bead of vertical-up position would be sunk. To investigate the size of back bead and keyhole with the change of the flow rate of pilot and shield gas at each position, bead-on plate welds were conducted on 6mm thickness SS400 with inclined-up position. When the rest of welding conditions remained constant, the width of back bead was increased as the flow rate of pilot gas was increased. And back bead tended to convex as the flow rate of shield gas was increased.

구배가 없는 신배수시스템의 제안 및 배수유동 특성에 관한 실험적 연구 (The Proposal of a New Drainage System without Incline of Piping and Experiment on Drainage Flow Characteristics)

  • 차영호;이정재
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.452-458
    • /
    • 2005
  • In Korea, pumping pipe using gravity way by water is most popular method in drainage system. But, it is difficult to repair a drainpipe in this method because the drain pipe diameter is increased as using this method. In this research, we propose a new drainage system. The system aim for an adaptedness with buildings, freedom of plan, construction and renewal in water pipe equipments, etc. The new system is not need of incline of piping, and it uses drainage power that is changed potential energy by high velocity flow as making Siphonage at vertical pipe. Therefore, the diameter of piping can decreased than existing piping system established in the ceiling. Also because connecting position will be located at the lower part, it is changed the potential energy of drainage to the high velocity flow. In addition, drainage will be smooth because the fixture drain is linked by each drain pipes.

An Analytic Study on Laminar Film Condensation along the Interior Surface of a Cave-Shaped Cavity of a Flat Plate Heat Pipe

  • Lee, Jin-Sung;Kim, Tae-Gyu;Park, Tae-Sang;Kim, Choong-Sik
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.966-974
    • /
    • 2002
  • An analytic approach has been employed to study condensate film thickness distribution inside cave-shaped cavity of a flat plate heat pipe. The results indicate that the condensate film thickness largely depends on mass flow rate and local velocity of condensate. The increasing rate of condensate film for circular region reveals about 50% higher value than that of vertical region. The physical properties of working fluid affect significantly the condensate film thickness, such as the condensate film thickness for the case of FC-40 are 5 times larger than that of water. In comparison with condensation on a vertical wall, the average heat transfer coefficient in the cave-shaped cavity presented 10∼15% lower values due to the fact that the average film thickness formed inside the cave-shaped cavity was larger than that of the vertical wall with an equivalent flow length. A correlation formula which is based on the condensate film analysis for the cave-shaped cavity to predict average heat transfer coefficient is presented. Also, the critical minimum fill charge ratio of working fluid based on condensate film analysis has been predicted, and the minimum fill charge ratios for FC-40 and water are about Ψ$\_$crit/=3∼7%, Ψ$\_$crit/=0.5∼1.3% respectively, in the range of heat flux q"=5∼90kW/㎡.

균일 난류 유동장내에서 연료입자의 퍼짐에 관한 연구 (A Study on the Dispersion of Fuel Particles in the Homogeneous Turbulent Flow Field)

  • 김덕줄;최연우
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1330-1337
    • /
    • 1994
  • This study is to predict the lateral dispersion of the particles with time in a vertical pipe. Particle is released downward and located in the center of a pipe through which stationary, homogeneous turbulent air is flowing. We assume that gas turbulence velocities have a Gaussian probability density distribution and the presence of particle is not to alter turbulent structures. Particle trajectory is computed by numerically integrating the particle Lagrangian equation of motion, with a random sampling to determine the fluctuating air velocity experienced by each particle, which considered inertia effect and crossing-trajectories effect. The result shows characterestics of particle dispersion according to flow field condition and droplet size by using the parameters and scales, which expressed characterestics of flow field and particle. Predictions agree reasonably with experimental data.

부가질량을 갖고 유동유체에 의한 송수관의 동적 안정성에 관한 실험적 검증 (Experimental Verification on Dynamic Stability of a Pipe with Attached Masses Conveying Fluid)

  • 김삼일;류봉조;정승호;류두현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.127-131
    • /
    • 2000
  • The paper presents both theoretical and experimental study for dynamic instabilities of a vertical cantilevered pipe with two attached lumped masses conveying fluid. The two attached lumped masses can be considered as valves or some mechanical parts in real pipe system. Eigenvalue behaviors depending on the flow velocity are investigated for the change of positions and magnitudes of an attached lumped mass and a tip mass. In order to verify appropriaty of numerical solutions, experiments were accomplished. Theoretical predictions have a good agreement with experimental ones.

  • PDF

아파트의 온수공급배관망해석 (Analysis on Heat Supply Piping Network for Apartment House)

  • 박윤철;황광일
    • 한국주거학회논문집
    • /
    • 제13권6호
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.