• Title/Summary/Keyword: Vertical Vibration Level

Search Result 101, Processing Time 0.024 seconds

Development of Vibration Absorption Device for the Transportation-Trailer System(I) - Characteristics for the existing vehicle - (수송 트레일러의 충격 흡수 장치 개발(I) - 보급기종에 대한 특성 및 진단 -)

  • 이홍주;홍종호;이성범;김성엽
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.89-96
    • /
    • 2003
  • This study was aimed to identify how the main body vibration of power tiller will be transmitted to the trailer, and to find out the basic information for demage reducing method of agricultural products during transportation. The vertical vibration acceleration level was measured at 6 positions, i.e. engine, hitch, seal and three parts of trailer (front middle, and rear) for the not driving but at the engine speeds of 1,000rpm and driving at 0.35m/s. The results of this research could be summarized as follows; 1. For not driving, the accumulated acceleration level up to 120Hz was 50% of total accelerations at engine part and those were 28~41% at other parts. Those up to 40Hz were 20~30% at engine and hitch part and 2~8% at trailer part. And those up to 20Hz were 13~20% at engine and hitch part and 1~4% at trailer part 2. For the driving with 0.35m/s at paved road, the average vertical accelerations were in the range of 0.005~0.058m/s$^2$. The lowest value of 0.005m/s$^2$ was showed at engine part and the value of 0.031-0.058m/s$^2$ was showed at trailer part. 3. For the driving with 0.35m/s, the accumulated value of average vertical accelerations showed the lowest value at engine parts md showed 5 times value of engine part at trailer part especially highest value at middle part of trailer. 4. For the driving with 0.35m/s, the accumulated acceleration level up to 120Hz was 75% of total accelerations at engine part and those were 20~42% at other parts. Ant those up to 20Hz and 40Hz were 24~26% at engine part and 0.1~0.6% at trailer part.

A Development of Prediction Program for Vertical Transfer Vibration of R/C Structure due to Traffic Loads (교통하중에 인접한 콘크리트 건축물의 진동예측 프로그램 개발)

  • Chun, Ho-Min;Hong, Kap-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.949-954
    • /
    • 2000
  • In terms of vibration damage and the serviceability for occupants in buildings, the purpose of vibration study lies in the reduction of vibration damage. However, only when vibration level of buildings is available, measures of vibration control and base isolation can be taken. The purpose of this paper is to provide a fundamental analysis method to estimate structural vibration. After analysing by using two methods, infinite model, combination method, a comparison between analysed results and the results of previous studies was performed to prove the validity of the prediction on the vibration of building structure. Thus, if the material property of soil and quantity of load sources are known before construction being started, the vibration level could be predicted by using these methods.

  • PDF

Determination of Recommendable Powered Drill Weight by the Characteristics of Transmitted Vibration on Hand-Arm System (전동드릴의 진동전달 특성에 따른 적정 드릴 무게의 결정)

  • Lee, Dong-Choon;Kim, Kil-Joo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.75-86
    • /
    • 2000
  • In this study, the characteristics of transmitted vibration on HAS(hand-arm system) were identified to evaluate physical load due to the work surface orientation, tool weight and push force during powered drilling tasks. The characteristics of transmitted vibration on work surface orientation showed that the acceleration of transmitted vibration on horizontal work surface was higher than that on the vertical work surface. Regarding the characteristics of transmitted vibration on tool weight, the vibration acceleration level becomes lower as the tool weight becomes heavier. The amount of transmitted vibration on hand-arm system was decreased down to the tool weight of 2.4kg. However, as the tool weight becomes heavier than 2.8kg, the amount of transmitted vibration was increased and had peak value at 3.2kg of tool weight. Regarding the characteristics of transmitted vibration on push force, the vibration acceleration level goes higher, as the push force becomes larger. The characteristics of transmitted vibration on the axis of vibration showed that the direction of $Z_h$ had the highest acceleration compared to the direction of $X_h$, and $Y_h$. The direction of $X_h$, $Y_h$ and $Z_h$ had the highest acceleration of transmitted vibration on the hand, wrist and elbow, respectively. The results of this study showed that the condition which affect the lowest physical load to the subject on the powered drilling task would be working with the 2.4kg of tool weight on the vertical work surface.

  • PDF

Analysis and Small Scale Model Expriment on the Vertical Vibration of the KT-23 Type Passenger Vehicle (KT-23형 여객 차량의 상하 진동 해석 및 축소모형 실험)

  • 최경진;이동형;장동욱;권영필
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.4
    • /
    • pp.266-273
    • /
    • 2003
  • The purpose of this study is to obtain the effects of the parameters of the suspension system in railway rolling-stock for KT-23 type Passenger vehicle. According to the analysis and the small scale model car test. optimal condition was obtained for the stiffness ratio of secondary spring to primary spring of the suspension system and the mass ratio of the bogie frame to the car body. The analysis of the study shows that if the car body mass is increased or secondary stiffness Is lowered, the vertical vibration level is reduced and the passenger comfort can be improved. Especially, strong peaks are occurred in the frequencies corresponding to the rotational speed of driving axle and vehicle wheel. Hence, in order to obtain the dynamic characteristics through the small scale model car, the driving method of the vehicle on the test bench, rotational characteristics of the wheel and the natural modes of vehicle should be investigated and be modified.

Dynamic Characteristics of Railway Plate Girder Bridges with Increase of Diesel Locomotive Speed (철도차량의 증속에 따른 판형교의 진동특성)

  • Cho, Eun Sang;Kim, Hyun Min;Hwang, Won Sup;Oh, Ji Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.6
    • /
    • pp.769-782
    • /
    • 2006
  • As the ambient vibration test (AVT) of railway bridges has a limited range of speed, it has a limitation in examining the dynamic behavior of bridges accordingto speed. Thus, in order to analyze the correlation between the speed of a train passing over a bridge and the bridge's dynamic response, we conducted a speed-increasing experiment using a real diesel locomotive. To analyze the acceleration response characteristics, we attached seven vertical accelerometers at equal intervals throughout the entire section of the bridge except the supports, and one horizontal accelerometer to the middle span. Linear variable differential transformers (LVDT) were installed at the bridge's center in both vertical and horizontal directions to investigate the vertical and horizontal behaviors. The test train was statically loaded at the center and at the end of the bridge. And its speed was increased from 5 km/h to 90 km/h. With data obtained from the experiment, the vibration level was evaluated in each direction by the filtering frequency, and the level of horizontal vibration was examined in comparison with vertical vibration. The displacement and wheel load variation was analyzed by speed.

A Study on Vibration of Vertical Pump (수직펌프의 진동 연구)

  • Kim, Yeon-Whan;Kim, Hee-Soo;Lee, Jun-Shin;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.58-63
    • /
    • 1997
  • The natural frequencies of the support system for a vertical pump, which are a key factor affecting the dynamic stability of the pump support system, are not easily predictable with analytical approaches only, due to the difficulties estimating the effective stiffness of the connections between the concrete base, the motor structure, the discharge elbow and the suction column of the pump system. This paper presents the results of a finite element analysis and an experimental study performed to identify and modify the characteristics of the pumping structure. The difficulties of modelling the effective stiffness were overcome by utilizing experimental results in the analysis. Based on analytical and experimental results, appropriate structural modifications are taken to reduce excessive vibration of the pump system to a satisfactory level.

  • PDF

On the Vibration Characteristics of Surface Blasting (지표발파의 진동특성에 관한 기초연구)

  • 양형식
    • Tunnel and Underground Space
    • /
    • v.2 no.2
    • /
    • pp.199-211
    • /
    • 1992
  • Blasting vibrations of 3 quarries and 5 construction sites were measured and investigated with two reference data. Square and cubic root scaled distance were similar in fitness to peak particle velocity of individual blasting site, but the former is better fitted in total. It was suggested that the limit scaled distance for domestic surface blasting be 40kg/$\textrm{cm}^2$ for 10mm/s level and 60kg/$\textrm{cm}^2$ for 5mm/s level, which were lower than the OSM's regulation. Prevailing vibration components were in the order of radial, vertical and transverse directions. Prevailing vibration components were in the order of radial, vertical and transverse directons. Site factors K and m were 242 and -1.283 for all studied area, 357 and -1.348 for construction sites, 118 and -1.160 for quarries. Most prevailing frequency was in the range of 10~2Hz. Overlapping effect of delayed blasting vibrations were insignificant. Vibration history of delayed blasting was longer than simultaneous blasting, and it became longer as measuring distance increased. Wave form and predominant frequencies were more complicated for delayed blasting than instantaneous blasting. The influence of blasting scale and measuring distance were not significant to determine peak particle velocity equation.

  • PDF

Determination of the Allowable Vibration Level of the Atomic Force Microscope Equipment (원자 현미경 장비의 바닥 진동(정상 상태) 허용 기준 결정)

  • Lee, Dong-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.161-164
    • /
    • 2000
  • Currently, Atomic Force Microscope(AFM) has been widely used to measure the surface topography of a sample by detecting interaction force between atoms on the sample and extremely sharp probe tip. The vertical resolution of AFM is mainly determined by external vibration noise. The resolution of AFM shows different values for the different environment, thus it is necessary to determine relationship between the criteria and the resolution of AFM regardless of environment. In this paper, we discuss the allowable level of floor vibration for AFM equipment at given resolution. The vibration criteria can be used as reference data to design mechanical structure and to analyze the structural dynamics of AFM equipment.

  • PDF

Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge (공용중인 PSC 거더 교량의 진동사용성 평가)

  • Park, Sun-Joon;Kang, Sung-Hoo;Kim, Bo-Hwoan;Kim, Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.781-786
    • /
    • 2009
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90m span, width of 5.5m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "Level C, Strongly Perceptible" and "Level B, Disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.

  • PDF

Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge (공용중인 PSC 거더 교량의 진동사용성 평가)

  • Kang, Sung-Hoo;Kim, Bo-Hwoan;Park, Sun-Joon;Kim, Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.331-337
    • /
    • 2010
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90 m span, width of 5.5 m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270 kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "level C, strongly perceptible" and "level B, disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.