• Title/Summary/Keyword: Vertical Resolution

Search Result 355, Processing Time 0.03 seconds

Atmospheric Profiles from KOMPSAT-5 Radio Occultation : A Simulation Study

  • Lee, Woo-Kyoung;Cho, Sung-Ki;Jo, Jung-Hyun;Park, Jong-Uk;Yoon, Jae-Cheol;Lee, Jin-Ho;Chun, Yong-Sik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.53-56
    • /
    • 2006
  • KOMPSAT (KOrea Multi-Purpose SATellite)-5 for the earth observation and scientific research is scheduled to launch in 2009. The second payload, AOPOD (Atmosphere Occultation and Precision Orbit Determination) system, consists of a space-borne dual frequency GPS receiver and a laser retro reflector. GPS radio occultations from AOPOD system can be used to generate profiles of refractivity, temperature, pressure and water vapor in the neutral atmosphere with a high vertical resolution. Also the radio occultation in the ionosphere provides an inexpensive tool of vertical electron density profile. Currently, many LEO missions with GPS radio occultation receivers are on orbit and more GPS occultation missions are planed to launch in the near future. In this paper, we simulated radio occultation measurements from KOMPSAT-5 and retrieved atmospheric profiles using the simulated data.

  • PDF

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

A Study on Vertiport Installation Standard of Drone Taxis(UAM) (드론택시(UAM)의 수직이착륙장(Vertiport) 설치기준 연구)

  • Choi, Ja-Seong;Lee, Seok-Hyun;Baek, Jeong-Seon;Hwang, Ho-Won
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.29 no.1
    • /
    • pp.74-81
    • /
    • 2021
  • UAM(Urban Air Mobility) systems have evolved in the form of helicopters in the 1960~1970s, tiltrotors in the 1980s, small aircraft transportation systems in the 2000s, and electric-powered Vertical Take-Off and Landing (eVTOL) in the 2010s; accordingly, the early heliport has evolved to its current form of a Vertiport. Vertical Takeoff and Landing Sites, Vertiports, are important factors for the successful introduction of UAM, along with the resolution of air traffic control (ATC), air security, and noise problems. However, there are no domestic or international installation standards and guidelines yet. Therefore, in this study, installation standards were prepared by referring to domestic and international case studies, ICAO standards, and MIT research papers. The study proposes to establish standards for Final Approach and Takeoff Area (FATO) as 1.5D, 1D for Touchdown and Lift-Off Area (TLOF), and 1.5D for Safety Area (SA). It also proposes to add "UAM Vertiport Installation Standards" to the 「Act on the Promotion and Foundation of Drone Utilization, Drone Act」.

Large-area High-speed Single Photodetector Based on the Static Unitary Detector Technique for High-performance Wide-field-of-view 3D Scanning LiDAR (고성능 광각 3차원 스캐닝 라이다를 위한 스터드 기술 기반의 대면적 고속 단일 광 검출기)

  • Munhyun Han;Bongki Mheen
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.4
    • /
    • pp.139-150
    • /
    • 2023
  • Despite various light detection and ranging (LiDAR) architectures, it is very difficult to achieve long-range detection and high resolution in both vertical and horizontal directions with a wide field of view (FOV). The scanning architecture is advantageous for high-performance LiDAR that can attain long-range detection and high resolution for vertical and horizontal directions. However, a large-area photodetector (PD), which is disadvantageous for detection speed, is essentially required to secure the wide FOV. Thus we propose a PD based on the static unitary detector (STUD) technique that can operate multiple small-area PDs as a single large-area PD at a high speed. The InP/InGaAs STUD PIN-PD proposed in this paper is fabricated in various types, ranging from 1,256 ㎛×949 ㎛ using 32 small-area PDs of 1,256 ㎛×19 ㎛. In addition, we measure and analyze the noise and signal characteristics of the LiDAR receiving board, as well as the performance and sensitivity of various types of STUD PDs. Finally, the LiDAR receiving board utilizing the STUD PD is applied to a 3D scanning LiDAR prototype that uses a 1.5-㎛ master oscillator power amplifier laser. This LiDAR precisely detects long-range objects over 50 m away, and acquires high-resolution 3D images of 320 pixels×240 pixels with a diagonal FOV of 32.6 degrees simultaneously.

Subsurface Geological Structure Using Shallow Seismic Reflection Survey (반사법 탄성파 탐사를 이용한 천부 지질 구조)

  • Kim Gyu-Han;Kong Young-Sae;Oh Jinyong;Lee Jung-Mo
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.1
    • /
    • pp.8-16
    • /
    • 1999
  • In terms of high resolution, seismic reflection survey is by far the most significant geophysical method applied to define subsurface structure. In shallow seismic reflection survey, it is, however, difficult to obtain high resolution image due to both the wave attenuation in the unconsolidated layer and the existence of source-generated surface waves Therefore, when collecting data, it is imperative to select proper equipments and choose optimum field data acquisition parameters for acquiring high S/N data. In this survey, a small size hammer was used as a low energy source and 40-Hz vertical geophones were used as receivers. Trigger signal was obtained from the hammer starter attached in the aluminum plate and thus it was possible to control the source onset time for the vertical stack. During the field work, a modified standard CMP technique was introduced to achieve the many-fold CMP data effectively. Data processing was conducted by the 'Seismic Unix' which is mounted on PC with a Linux operating system. The main distinctions were the emphasis and detail placed on near-surface velocity analysis and the extra care exercised in muting.

  • PDF

A Study on the Active Force of Extraocular Muscles (외안근의 운동력에 관한 연구)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.117-122
    • /
    • 2010
  • Purpose: The purpose of this study was to measure the active force of extraocular muscles on mono- and binocular movements for 62 healthy koreans (male: 29, female: 33). Methods: The force of adduction, abduction, elevation and depression, of right and left eye on monocular movement were tested with horizontal moving distance based on corneal limbus and the force of superior oblique muscle and inferior oblique muscle on binocular movement were measured with vertical moving distance between corneal limbus. The distances were obtained by high resolution digital image processing. Results: At monocular movements of tested subjects. the power of abduction, adduction, elevation and depression of right and left eye were (male) 9.35 nun, 9.75 mm, (female) 9.02 mm, 9.52 mm, (male) 10.23 mm, 10.16 mm, (female) 10.17 mm, 10.07 mm, (male) 7.01 mm,6.91 mm, (female) 6.98 mm, 6.64 mm, (male) 7.52 mm, 6.82 mm, (female) 7.52 mm, 6.67 mm, respectively. The active force of binocular movements were 54.8% hyperergasia and 45.1% hypergasia/67.7% hyperergasia and 32.2% hypergasia with inferior oblique muscle, 64.5% hyperergasia and 35.5% hypergasia/58.1% hyperergasia and 41.9% hypergasia with superior oblique muscle, respectively. Conclusions: The force of horizontal movement was higher than vertical movement. The value of adduction was higher than abduction on horizontal movement, and the value of depression was higher than elevation on vertical movement. In the both of inferior and superior oblique muscle, the ratio of hyperergasia was higher than that of hypergasia.

Dust/smoke detection by multi-spectral satellite data over land of East Asia (동아시아 지역의 육상에서 다중채널 위성자료에 의한 황사/연무 탐지)

  • Park, Su-Hyeun;Choo, Gyo-Hwang;Lee, Kyu-Tae;Shin, Hee-Woo;Kim, Dong-Chul;Jeong, Myeong-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.3
    • /
    • pp.257-266
    • /
    • 2017
  • In this study, the dust/smoke detection algorithm was developed with a multi-spectral satellite remote sensing method using Moderate resolution Imaging Spectroradiometer (MODIS) Level 1B (L1B) data and the results were validated as RGB composite images of red(R; band 1), green(G; band 4), blue(B; band 3) channels using MODIS L1B data and Cloud-Aerosol Lidar with Orthogonal Polarization Satellite Observations(CALIPSO) Vertical Feature Mask (VFM) product. In the daytime on March 30, 2007 and April 27, 2012, the consistencies between the dust/smoke detected by this algorithm and verification data were approximately 56.4 %, 72.0 %, respectively. During the nighttime, the similar consistency was 40.5 % on April 27, 2012. Although these results were analyzed for limited cases due to the spatiotemporal matching for the MODIS and CALIPSO satellites, they could be used to utilize the aerosol detection of geostationary satellites for the next generations in Korea through further research.

1/10,000 Scale Digital Mapping using High Resolution Satellite Images (고해상도 위성영상을 이용한 축척 1/10,000 수치지도 제작)

  • Lee, Byung-Hwan;Kim, Jeong-Hee;Park, Kyung-Hwan;Chung, Il-Hoon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.2
    • /
    • pp.11-23
    • /
    • 2000
  • The subjects of this study are to examine and to apply the methods of making 1 : 10,000 scale digital maps using Russian's 2 m resolution satellite images of Alternative and 8 m resolution stereo satellite images of MK-4 for the Kyoha area of Paju-city where aerial-photo surveying is not possible. A digital elevation model (DEM) was calculated from MK-4 images. With this DEM, the Alternative images were orthorectified. Ground control points (GCP) were acquired from GPS surveyings and were used to perform geometric corrections on Alternative images. From field investigation, thematic attributes are digitized on the monitor. RMS errors of the planar and vertical positions are estimated to ${\pm}0.4$ m and ${\pm}15$ m, respectively. The planar accuracy is better than an accuracy required by NGIS (national GIS) programs. Local information from field investigation was added and the resulting maps should be good as base maps for, such as, regional and urban plannings.

  • PDF

Digital Surface Model Generation using Aerial Lidar Data and Ground Control Point Acquisition (항공 라이다 데이터를 이용한 공간해상도별 수치표면모형 제작 및 지상기준점 획득 가능성 분석)

  • Kim Kam-Rae;Hwang Won-Soon;Lee Ho-Nam
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.485-490
    • /
    • 2006
  • In this study, the Digital Surface Models of various spatial resolutions were constructed using LIDAR point data on Digital Photogrammetric System. Then, the accuracies of each DSM's were evaluated using GPS surveying data. And also, observable features were classified and their accuracies were evaluated to verify the availability for Ground Control Point. On Socet Set, Digial Photogrametric System 5 DSM's of which spatial resolutions were 0.15m, 0.5m, 1.0m, 2.5m and 5.0m were constructed and the accuracies of eahc DSM's evaluated in RMSE. The RMSE's of each DSM's were 0.03m, 0.05m, 0.08m, 0.12m and 0,19m. The building feature was observable in DSM's of which spatial resolutions were 0.15m, 0.30m and 0.50m. On the contrary, it could hardly be observed in those of other spatial resolutions. In comparison with the digital map at the scale of 1:1,000, the DSM at the spatial resolution of 0.lim was shifted horizaltally by 0.6m-0.7m of RMSE in each X, Y direction. Therefore, GCP of which horizontal RMSE is better than 1m can be obtained from the DSM at the spatial resolution of 0.15m, of which vertical RMSE is 0.03m-0.19m as the RMSE of DSM. This point cannot be used in aerial triangulation of cartography but can be used for GCP in modeling of satellite image at the moderate resolution.

  • PDF

Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.