• 제목/요약/키워드: Vertical Parallel Plate

검색결과 35건 처리시간 0.025초

조건이 다른 수직 평형 평판에서 혼합대류 열전달 (Mixed Convection Heat Transfer from Two Vertical Parallel Plates with Different Conditions)

  • 김상영;정한식;권순석
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.243-252
    • /
    • 1992
  • A mixed convection heat transfer from two vertical parallel plates has been studied numerically by the finite difference method. Effects of the Grashof number, the relative length, $L_2/L_1$. the dimensionless temperature ratio, ${\Phi}_2/{\Phi}_1$ and the dimensionless plate spacing, $b/L_1$ are examined for the heat transfer. Independent of the Grashof numbers and $L_2/L_1$, the dimensionless vertical velocity distributions skewed on the left plate as ${\Phi}_2/{\Phi}_1$ decreased. The dimensionless vertical velocity distribution for $Gr/Re^2=1$ and ${\Phi}_2/{\Phi}_1=1.0$ is skewed to the right plate $L_2/L_1=0.5$, symmetric at $L_2/L_1=1.0$ and skewed to the left plate at $L_2/L_1=1.5$. But for $Gr/Re_2=10.0$ and ${\Phi}_2/{\Phi}_1=1.0$ reversed velocity patterns are obtained. Regardless of the Grashof numbers and $L_2/L_1$, the mean Nusselt nembers on the inside surface of the left plate decreases and those of the right inside surface increases as ${\Phi}_2/{\Phi}_1$ increases. Temperature, velocity and mean Nusselt number distributions are apparently not affected by $L_2/L_1$.

  • PDF

수직 평행평판에서의 혼합대류 열전달 (Combined Convective Heat Transfer from Vertical Parallel Plates)

  • 양성환;권순석
    • 대한기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.299-306
    • /
    • 1989
  • 본 연구에서는 밀집형 열교환기에 사용되고 있는 루우버 핀에 해당되는 간단한 형상인 등온, 수직, 평행평판에서의 혼합대류 열전달에 관하여 Pr=0.7, Gr=$10^{4}$ 및 50<Re$_{L}$<500인 경유 평판간격과 평판길이를 변수로 하여 유한차분법으로 수치해석하였다. 속도분포, 온도분포 및 Nusselt수를 구하여 평판의 간격과 길이가 열전달에 미치는 영향에 관하여 연구하였다.

등온 수직 평판에서의 혼합대류 열전달 (Mixed convection from two isothermal, vertical, parallel plates)

  • 박문길;이재신;양성환;권순석
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1645-1651
    • /
    • 1990
  • 본 연구에서는 두 개의 수직 등온 평판이 평행하게 배열된 경우의 혼합대류 열전달에 대하여 무차원 평판 간격, b/l와 Grashof수, 레이놀즈수를 변수로 유한차분 법을 사용 수치해석하고, 두평판사잉의 간섭현상과 열전달을 최대로 하는 최적 평판간 격을 구하였다.

지중매설 연성관의 관강성 추정 (Pipe Stiffness Prediction of Buried Flexible Pipes)

  • 박준석;김선희;김응호
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.13-20
    • /
    • 2012
  • In this paper, we present the result of an investigation pertaining to the pipe stiffness of buried flexible pipes. Pipe stiffness (PS) formula for the parallel plate loading condition is derived based on the elasticity theory. Vertical and horizontal displacements are also derived. Vertical deflection is always larger than the horizontal deflection because some of energy due to overburden load is stored in the pipe but the difference is negligibly small. In the study, mechanical properties of the flexible pipes produced in the domestic manufacturer are tested and the results are reported in this paper. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is less than 14% although there are significant variations in the mechanical properties of the pipe material. Therefore, it was found that the finite element analysis can be used to predict the pipe stiffness instead of conducting parallel plate loading test.

수직 등온 평행 평판에서 상호작용 유동이 대류 열전달에 미치는 영향 (The Effect of the Interactive Flow on Convective Heat Transfer from two Vertical Isothermal Parallel Plates)

  • 김상영;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.765-774
    • /
    • 1992
  • 본 연구에서는 수직 등온 평행평판의 혼합대류 열전달에 대하여 두 평판의 길 이가 다른 경우를 고찰하고자 Reynolds수, Grashof수, 평판간격을 변수로 하여 수치해 석 하였다.

착상조건하에서 평행 평판 열교환기의 열 및 물질전달 (Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition)

  • 이관수;이태희;김우승
    • 설비공학논문집
    • /
    • 제6권2호
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

층류유동 저습도 조건에서의 평행평판형 냉각판 서리성장 실험 (Experiment of frost growth on the parallel plates in the condition of laminar and low humidity)

  • 한흥도;노승탁
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.440-447
    • /
    • 1999
  • The frosting characteristics on the vertical parallel plates with three cooling plates were experimentally investigated. The experimental parameters were the cooling plate temperature, the air humidity, the air temperature, the air Reynolds number, and the location. The frosting conditions were limited to air temperatures from 10 to $15^{\circ}C$ , air Reynolds numbers from 1600 to 2270, air humidity ratios from 0.00275 to 0.0037kgw/kga and cooling plate temperatures from -10 to $-20^{\circ}C$. Frost growth and density toward the front of the plate were more thick and dense than toward the rear. Frost growth increased with decreasing plate temperature and increasing humidity. In the conditions of the laminar flow, dew point below $0^{\circ}C$and non-cyclic frosting period, frost thickness increased with increasing air temperature. The reason of increasing frost thickness with increasing air temperature was sublimation-ablimation process. The average growth thickness along the locations showed little dependence on the Reynolds numbers.

  • PDF

Application of the Method of Moments to the Capacitance Computation of a Parallel-Plate Rectangular Capacitor

  • Roh, Young-Su
    • 조명전기설비학회논문지
    • /
    • 제28권11호
    • /
    • pp.93-99
    • /
    • 2014
  • The method of moments is applied to numerically compute the electrostatic capacitance of a parallel-plate rectangular capacitor of finite area. Each plate is discretized into 900 patches per unit area to ensure a high accuracy of computation. To further enhance computational results, the impedance matrix elements are additionally evaluated in the case that the observation patch is located above or below the source patch in the vertical direction. To examine the fringing effect at the edges of the capacitor, the normalized capacitances are computed as a function of separation distance. After these results have been verified by Palmer's formula, this method is extended to the computation of capacitances between two different size plates.

Pull-in과 release 전압차 감소용 돌기구조를 갖는 비틀림형 초소형 기계적 스위칭 소자 (Torsional Micromechanical Switching Element Including Bumps for Reducing the Voltage Difference Between Pull-in and Release)

  • 하종민;한승오;박정호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.471-475
    • /
    • 2001
  • ln this paper, a micromachined micromechanical switch is presented. The presented switch is operated in the vertical direction to the substrate by an electrostatic force between two parallel plates. The moving plate is pulled down to connect the bumps of the bias node$(V_{DD}/ or GND)$ to the bumps of the output node when a oltage difference exists between the moving plate and the input plate. The switch was designed to operate at a low switching voltage$(\risingdotseq5V)$ by including a large-area, narrow-gap, parallel plate capacitor A theoretical analysis of the designed switch was performed in order to determine its geometry fitting the desired pull-in voltage and release voltage. The designed switch was fabricated by surface micromachining combined with Ni electroplating. From the experimental results of the fabricated switch, its pull-in voltage came Out to be less than 5V and the measured maximum allowable current was 150mA. The measured average ON-state resistance was about 8$\Omega$, and the OFF-state resistance was too high to be measured with digital multimeter.

  • PDF

See-saw Type RF MEMS Switch with Narrow Gap Vertical Comb

  • Kang, Sung-Chan;Moon, Sung-Soo;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.177-182
    • /
    • 2007
  • This paper presents the see-saw type RF MEMS switch based on a single crystalline silicon structure with narrow gap vertical comb. Low actuation voltage and high isolation are key features to be solved in electrostatic RF MEMS switch design. Since these parameters in conventional parallel plate RF MEMS switch designs are in trade-off relationship, both requirements cannot be met simultaneously. In the vertical comb design, however, the actuation voltage is independent of the vertical separation distance between the contact electrodes. Therefore, the large separation gap between contact electrodes is implemented to achieve high isolation. We have designed and fabricated RF MEMS switch which has 46dB isolation at 5GHz, 0.9dB insertion loss at 5GHz and 40V actuation voltage.