• 제목/요약/키워드: Vertical Absorber

검색결과 89건 처리시간 0.023초

Heat Transfer Performance of Various Tubes for an Air-cooled Absorber with Surfactant

  • Yoon, Jung-In;Kim, Eun-Pil;Moon, Choon-Geun;Kwon, Oh-Kyong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.1-10
    • /
    • 2000
  • This research is concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes are a bare tube, a groove tube, a corrugated tube and a spring-inserted tube. The additive concentration is about 0.08 mass%. The heat transfer coefficient is measured as a function of the film Reynolds number in the range of 20~200. Experiments are carried out at higher cooling water temperature of $35^{\circ}C$to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results with and without surfactant are compared. The enhancement of heat transfer by Marangoni convection effect which is generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an spring-inserted has the enhancement effect.

  • PDF

Refilled mask structure for Minimizing Shadowing Effect on EUV Lithography

  • Ahn, Jin-Ho;Shin, Hyun-Duck;Jeong, Chang-Young
    • 반도체디스플레이기술학회지
    • /
    • 제9권4호
    • /
    • pp.13-18
    • /
    • 2010
  • Extreme ultraviolet (EUV) lithography using 13.5 nm wavelengths is expected to be adopted as a mass production technology for 32 nm half pitch and below. One of the new issues introduced by EUV lithography is the shadowing effect. Mask shadowing is a unique phenomenon caused by using mirror-based mask with an oblique incident angle of light. This results in a horizontal-vertical (H-V) biasing effect and ellipticity in the contact hole pattern. To minimize the shadowing effect, a refilled mask is an available option. The concept of refilled mask structure can be implemented by partial etching into the multilayer and then refilling the trench with an absorber material. The simulations were carried out to confirm the possibility of application of refilled mask in 32 nm line-and-space pattern under the condition of preproduction tool. The effect of sidewall angle in refilled mask is evaluated on image contrast and critical dimension (CD) on the wafer. We also simulated the effect of refilled absorber thickness on aerial image, H-V CD bias, and overlapping process window. Finally, we concluded that the refilled absorber thickness for minimizing shadowing effect should be thinner than etched depth.

배연탈황설비 덕트쿨러에서의 유동균일화에 관한 연구 (A study on a uniformity of flow field in a duct cooler of FGD system)

  • 배진효;김광추;박만흥;박경석;이종원
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.120-130
    • /
    • 2000
  • A flow uniformity in a duct cooler of duct system of FGD(Flue Gas Desulfurization) linking a reheater and a absorber has been investigated in the present study. For this purpose, the flow characteristics according to the geometry of a vertical and horizontal vane in a curved duct of the duct system has been examined with the aid of a numerical simulation. The results indicate that the vertical vane with a little deflection toward a recirculation region makes the flow distribution in the duct cooler more uniform than that without deflection, and horizontal vane does not effect the change of the flow distribution for an angle of inclination. The mean flow uniform factor shows its maximum for duct system without the vane(case NP) and its minimum for the vertical vane with a little deflection(case P-0.8-0) .

  • PDF

모델링 및 시뮬레이션 기반의 함정용 수직발사형 발사체의 수중폭발 충격에 대한 내충격성 확보 방안 연구 (A Study on the Shock Resistance against Underwater Explosion of Ship-born Vertical Launch Type Air-vehicle by Using the Modeling and Simulation)

  • 이승진;권정일;유경식;박진용
    • 한국시뮬레이션학회논문지
    • /
    • 제32권4호
    • /
    • pp.1-10
    • /
    • 2023
  • 본 연구는 모델링 및 시뮬레이션을 이용하여 수중폭발 충격이 함정에 탑재되는 수직발사형 발사체에 전달될 때의 반응을 검토하고 발사체 보호를 위해 내충격성을 확보하는 방안에대한 것이다. 정확한 수학적 모델을 확보하기 위하여 유사 장비에 대한 동특성 시험을 수행하였으며 이를 기반으로 수학적 모델을 보완하였다. 그리고 보완된 수학적 모델에 이용하여 수직발 사체에 BV043 규격에서 정한 수중폭발에 의한 충격이 전달되는 상황을 시뮬레이션 하였다. 1차 시뮬레이션 결과 비행체의 구조물이 견딜 수 없는 충격이 전달되는 것을 확인하였으며, 링스프링 구조의 완충기를 사용하여 비행체를 보호하는 방안을 연구하였다. 또한 링스프링 완충기의 설계 변수를 변경한 여러 경우에 대한 시뮬레이션을 수행함으로써 링스프링 완충기가 함정탑재용 수직발사 비행체의 내충격성을 더 증가시킬 수 있음을 확인하였다.

수치적 시뮬레이션과 충격 시험을 통한 수직방향 진동절연 완충기 설계 및 성능 평가 (Design and Performance Evaluation of the Vibration Absorber of Vertical Direction Using Numerical Simulation and Shock Test)

  • 박상길;방승우;권오철;이정윤;오재응
    • 한국소음진동공학회논문집
    • /
    • 제18권5호
    • /
    • pp.558-563
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc' spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock Isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing $h_o/t$ ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

수치 모델링과 충격 시험을 통한 수직방향 진동절연 완충기의 성능 평가 (Performance Evaluation of the Vibration Absorber of Vertical Direction using Numerical Modeling and Shock Test)

  • 박상길;방승우;권오철;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.990-993
    • /
    • 2008
  • Vibration/shock affects biggest taking a train subtraction of vehicle and durability decline. Therefore, absorber is used for vibration/shock isolation and various qualities of the material and design are applied to isolation. This paper proposes vibration/shock absorber that applies 'Disc'spring. Through comparison with 'Disc' spring that has nonlinearity and coil spring that is having linearity, see effect that nonlinearity of isolation gets in vibration/shock isolation. Coil spring and 'Disc' spring are non-linear numerical analysis and simulation through theory for this, get and investigate comparison result through an experiment finally. Expressed and formulated shock through 'Runge-Kutta' method/impact response to nonlinear-vibration-equation of 1 degree of freedom for numerical analysis. Double half sine pulse of excitation used and analyzed result through spectrum response analysis here. Response of disc spring is compared to response of coil spring by changing ho/t ratio with computer simulation and the usage of disc spring is increased through analysis of effect of design factors. The purpose of this paper is that the shock response of disc spring is calculated through numerical simulation and to design the optimal absorber under the limited condition. And then, the isolation effect was analyzed through the shock test.

  • PDF

압전세라믹 감지기와 작동기를 이용한 방진 시스템 개발 (Development of the Vibration Isolation System using Piezoceramic Sensors and Actuators)

  • Seok Heo;Moon K. Kwak
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.309.2-309
    • /
    • 2002
  • This paper is concerned with the development of the vibration isolation system using piezoelectric actuators and sensors. The active vibration absorber system consists of 4 pairs of PZT actuators bonded on aluminum plates making s- shaped device. Hence, the active system is directly connected to the passive system. The rubber attached to the end of the beam is connected to the upper base as a structural member. It allows bending thus maximizing the vertical movement generated by the piezoceramic actuators. (omitted)

  • PDF

수직관내 삽입기구에 의한 흡수특성의 향상 (Improvement of absorption characteristics by insert devices in a vertical tube)

  • 김병주;신광섭;문형석
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.466-474
    • /
    • 1998
  • In the present study, the improvement of absorption characteristics by installing insert devices, such as spring and wire screen, inside the vertical tube absorber were studied experimentally. Momentum, heat and mass transfer rate in the absolution process of smooth bare tube, smooth tube with spring-insert, and with wire screen-insert were compared and analysed in range of film Reynolds number of 40∼200. The improvement of heat transfer rate by spring-insert and screen-insert were remarkable especially in the low Reynolds number region. As the mesh number increased in screen-insert and as the pitch decreased in spring-insert, Nusselt and Sherwood number increased. Degradation of mass transfer by non-absorbable gas showed similar qualitative trends regardless of the insert type.

  • PDF

압전세라믹 감지기와 작동기를 이용한 방진 시스템 개발 (Development of the Vibration Isolation System using Piezoceramic Sensors and Actuators)

  • 허석;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.6-11
    • /
    • 2002
  • This paper is concerned with the development of the vibration isolation system using piezoelectric actuators and sensors. The active vibration absorber system consists of 4 pairs of PZT actuators bonded on aluminum plates. Hence, the active system is directly connected to the passive system. The rubber attached to the end of the beam is connected to the upper base as a structural member. It allows bending thus maximizing the vertical movement generated by the piezoceramic actuators. The piezoceramic sensors consists of 4 PZT sensors known to tilting, rolling and vertical movement. This paper also presents the development and the movement of the system.

  • PDF

Effect of Wavy Flow of Vertical Falling Film on the Absorption Performance

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권3호
    • /
    • pp.158-166
    • /
    • 2005
  • The present study investigated experimentally and numerically the enhancement of absorption performance due to the waviness of falling film in the vertical absorber tube. The momentum, energy and mass diffusion equations were utilized to find out temperature and concentration profiles at both the interfaces of liquid solution and refrigerant vapor and the wall. Flow visualization was performed to find out the wetting characteristics of the falling film. The maximum heat transfer coefficient was obtained for the wavy flow using spring as an insert device through both numerical and experimental studies. Based on the numerical and experimental results, the maximum absorption rate was found for the wavy-flow using spring as the insert device. The differences between experimental and analytical results ranged from $5.0\;to\;25\%\;when\;Re_j>100$.