• Title/Summary/Keyword: Vernier analysis

Search Result 27, Processing Time 0.027 seconds

Wood Shrinkage Measurement of Using a Flatbed Scanner (평판형 스캐너를 이용한 목재 수축률 측정)

  • Park, Yonggun;Chang, Yoon-Seong;Yang, Sang-Yun;Yeo, Hwanmyeong;Lee, Mi-Rim;Eom, Chang-Deuk;Kwon, Ohkyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.43-51
    • /
    • 2015
  • Wood shrinkage, an important study subject with regard to the use of wood, has long been studied by researchers. However, when the size of a wood specimen is measured, distortion must be taken into account, which can be accomplished by applying external force on the wood specimen. However, when measuring a large number of specimens, this technique can be a lengthy process. If the size is measured and the shrinkage is calculated from images acquired with a flatbed scanner, it is possible to reduce the error in the measurement and to shorten the measurement time because the images of many specimens can be acquired with one scan. To clearly establish the boundary between a wood specimen and the background in a scan, an image threshold method was applied here. The size of a wood specimen measured by means of a scanner image was found to be longer than the value determined with a vernier caliper. The maximum pixel size of a scan image for highly accurate shrinkage calculations compared with the use of a vernier caliper was 0.053 mm/pixel.

AN OPTICAL FIBER FEED LITTROW-MOUNTED SPECTROMETER (광섬유 피드 리트로마운트형 분광계)

  • Bae, J.H.;Song, J.W.;Yoon, T.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.87-93
    • /
    • 2012
  • A low-dispersion fiber feed Littrow-mounted grating spectrometer for education was designed and fabricated. The dispersion element is a reflective type blazed grating Edmundoptics NT 46-075 (spatial frequency 600 lines/mm, dimension $30mm{\times}30mm$, blazed angle 8.6 degree). The optical fiber coupler module for optical guiding from telescope to spectrometer is composed of a multi-mode FC connector - FC connector optical fiber patch cord (core/cladding diameter $50{\mu}m/125{\mu}m$) and two 1.25" throw-tube couplers. The lens for collimating and imaging is a general purpose focal length 50 mm camera lens (f/1.8). The device for optical path control is a rectangular prism (size $25mm{\times}25mm$). The imaging camera sensor is a Meade DSI Pro 2 CCD sensor (black and white, $752{\times}582$ pixels and pixel size $8.3{\mu}m{\times}8.6{\mu}m$). Softwares for data logging and analysis consist of Meade Autostar Suite, NIH imagej and Vernier Logger Pro 3. The wavelength coverage range of the spectrometer is 205 nm at central wavelength 550 nm. The wavelength resolution is 1.7 nm.

Classification of Adult Women's Fingernail Type (성인 여성의 손톱 유형 분류)

  • Kim, Ha Eun;Kim, Nam Soon;Do, Wol Hee
    • Fashion & Textile Research Journal
    • /
    • v.22 no.4
    • /
    • pp.504-514
    • /
    • 2020
  • This study improves the dimensional suitability of nail tip products by reviewing the type of fingernail as seen among adult women in Korea. Subjects were 147 adult women ranging from age 20 to 40. Direct fingernails measurements were made using digital Vernier calipers and a curvature gauge. Data on various fingernail shapes were collected through indirect measurements using photography to reveal the shape characteristics of each fingernail types. In this sense, data were analyzed by statistical methods with the use of factor analysis. There were various factors considered to classify extracted fingernail types such as five factors (for the thumb), four factors (index, middle, and little fingers), and three factors (for the ring finger). The cluster analysis resulted in three types. Type 1 is a 'Square' shape characterized with wide fingernails, low height, flat, and low curvature of the cuticle line. Type 2 is 'U-round' shape characterized with narrow fingernails, high height, convex, and the highest curvature of the cuticle line. Type 3 is a 'Round' shape in which the fingernails are wide, high in height, convex, and characterized with a medium curvature of the cuticle line. The results are useful for companies that develop the free edge shape of fingernails for consumer products. The measured values of fingernail can be applied to the shape and lake setting of the nail tip product, depending on type of fingernail.

Relationship between Gender Roles and Job Satisfaction among Neurological Physical Therapists

  • Park, Ji-Whan;Han, Seul-Ki;Lee, Dae-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.81-88
    • /
    • 2016
  • PURPOSE: This study was aimed at investigating the types of gender roles and the relationship between gender roles and job satisfaction among neurological physical therapists. METHODS: The study subjects were 169 (male 74, female 95) neurological physical therapists working at general hospitals or rehabilitation centers in the Daejeon Metropolitan City area, South Korea. To identify job satisfaction scores, the subjects completed a questionnaire, and a vernier caliper was used by a trained examiner to measure the lengths of the subjects' index and ring fingers (i.e., digitus secundus manus and digitus annularis, respectively) to examine gender roles. The index to ring finger length ratio (i.e., 2D:4D ratio) was calculated using a personal computer. An independent t-test was performed to compare the finger length ratio and job satisfaction of male group with that of the female group and a correlation analysis was performed to examine job satisfaction by gender roles. RESULTS: Finger length ratio is lower in males than in females. However, there was no significant difference statistically (p>.05). Regarding job satisfaction by gender, males were more satisfied with their jobs than females (p<.05). However, there were no significant correlations between job satisfaction and gender roles (p>.05). CONCLUSION: It cannot be concluded that bias against gender roles is a contributing factor for neurological physical therapists being satisfied with their job, and thus bias against gender roles among neurological physical therapists should be removed.

Comparison of Asymmetries on Masseter Muscle Thickness and Range of Motion in Subject With and Without Temporomandibular Disorders (턱관절 장애 유무에 따른 깨물근의 두께와 턱관절 가동범위의 비대칭성 비교)

  • Lee, Ji-won;Yang, Yeon-ju;Won, Jong-im
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.28-36
    • /
    • 2019
  • Background: Temporomandibular disorder (TMD) is characterized by pain and limited range of motion in the jaw. TMD patients generally prefer to chew on the unaffected or less-affected side, and this tendency often results in asymmetries in masseter muscle thickness and range of mandibular motion. Objects: The purpose of this study was to compare the asymmetries in masseter muscle thickness and range of mandibular motion in subjects with and without temporomandibular disorders. Methods: Thirty-nine subjects were divided into two groups: A TMD group ($n_1=19$) and a control group ($n_2=20$). The jaw opening range and laterotrusion were measured using a digital vernier caliper. The masseter muscle thickness was examined in both the resting state and the maximal clenching state using ultrasonography. The absolute asymmetry indices calculated based on the laterotrusion and masseter muscle thickness of the respective right and left sides. A two-way ANOVA and a Mann-Whitney U test were used for statistical analysis. Results: No significant different was found in the masseter muscle thickness between the TMD and control group. A significant difference was found in the absolute asymmetry indices of mandibular laterotrusion between the TMD and control groups (p<.05). Furthermore, the ranges of jaw opening were significantly different between males and females (p<.05). The absolute asymmetry index values of masseter muscle thickness at rest and during maximal clenching were also significantly different between males and females (p<.05). Conclusion: These results demonstrated that the subjects with TMD had a larger degree of asymmetry in laterotrusion than those without TMD. Therefore, a physiotherapy program needs to be designed to restore normal laterotrusion capacities for TMD subjects. These results also showed that female subjects had greater absolute asymmetry indices in masseter muscle thickness than male subjects. Therefore, more training is needed to promote bilaterally balanced chewing among women.

Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.13 no.2
    • /
    • pp.52-58
    • /
    • 2020
  • Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower first premolars and two mandibular acrylic models (A and B) were used in this study. In the artificial teeth, the pulp chamber was opened and the access cavity was prepared. Using calibrated digital Vernier calipers, the distance from the top of the cavity and the root apex was measured to assess the actual distance between two artificial teeth. The evaluation was conducted by 20 dentists, and each evaluator repeated measurements for each electronic apex locator five times. The difference between the actual distance from the top of the cavity to the root apex and the distance measured using electronic measuring equipment was compared. For statistical analysis, the Friedman test the Mann-Whitney U-test were conducted and the differences between groups were analyzed (α=0.05). Result: As for the accuracy of measurement according to the two types of electronic apex locators, the value of the measurement error was 0.4753 mm in Dentaport ZX and 0.3321 mm in E-Cube Plus. Moreover, electronic apex locators Dentaport ZX and E-Cube Plus showed statistically significant differences (P<0.05). As for the difference in the accuracy of the two types of electronic apex locators according to the evaluator, the resulting values differed depending on the evaluator and showed a statistically significant difference (P<0.001). Conclusion: Electronic apex locator E-Cube Plus showed higher accuracy than did Dentaport ZX. Nevertheless, both types of electronic apex locators showed 100% accuracy in finding the region within root apex ±0.5 mm zone. Furthermore, according to the evaluator, the two electronic apex locators showed different resulting values.

Analysis of size distribution of riverbed gravel through digital image processing (영상 처리에 의한 하상자갈의 입도분포 분석)

  • Yu, Kwonkyu;Cho, Woosung
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.7
    • /
    • pp.493-503
    • /
    • 2019
  • This study presents a new method of estimating the size distribution of river bed gravel through image processing. The analysis was done in two steps; first the individual grain images were analyzed and then the grain particle segmentation of river-bed images were processed. In the first part of the analysis, the relationships (long axes, intermediate axes and projective areas) between grain features from images and those measured were compared. For this analysis, 240 gravel particles were collected at three river stations. All particles were measured with vernier calipers and weighed with scales. The measured data showed that river gravel had shape factors of 0.514~0.585. It was found that the weight of gravel had a stronger correlation with the projective areas than the long or intermediate axes. Using these results, we were able to establish an area-weight formula. In the second step, we calculated the projective areas of the river-bed gravels by detecting their edge lines using the ImageJ program. The projective areas of the gravels were converted to the grain-size distribution using the formula previously established. The proposed method was applied to 3 small- and medium- sized rivers in Korea. Comparisons of the analyzed size distributions with those measured showed that the proposed method could estimate the median diameter within a fair error range. However, the estimated distributions showed a slight deviation from the observed value, which is something that needs improvement in the future.

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

A STUDY ON THE SELECTION OF THE MAXILLARY ANTERIOR ARTIFICIAL TEETH IN KOREAN ADULTS (한국 성인의 상악 전치부 인공치아 선택기준에 관한 계측학적 연구)

  • Ahn Hyun-Jeong;Yang Hong-So;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.484-492
    • /
    • 2002
  • The selection of the maxillary anterior artificial teeth is made primarily for esthetics and they must be in harmony with the surrounding oral environment. However the selection of artificial teeth is based on the large degree of subjective judgement or the dentists, therefore, this is one of the most unscientific processes. This study was performed to determine clinically whether there is correlation among the width of the maxillary central incisor(WMCI), the intercanine distance (ICD) the facial width(FW), and the interalar nasal width(IAW) in Korean adults, and to provide the selection standards for the maxillary anterior artificial teeth. The casts were obtained from 91 undergraduate dental students(49 males and 42 females) with Angle's class I occlusion presenting well-arranged intact anterior teeth. The WMCI and ICD were measured on the casts with a vernier calipers($Miltex^{(R)}$, Germany). The photographic procedures under standardized conditions were performed to record each subject's frontal face using digital camera($Olympus^{(R)}$, C-2500L, Japan). The FW and IAW were measured with image analyzer($Image-Pro^{(R)}$ PLUS. media cybermetrics. USA). The results were obtained as follows : 1. The mean WMCI was $8.11{\pm}0.67mm$, ICD was $37.88{\pm}2.15mm$, FW was $141.29{\pm}5.84mm$. and IAW was $37.85{\pm}2.29 mm$. 2. The ratios of FW/WMCI, FW/ICD, IAW/ICD were 17.4, 3.7, 1.0 respectively. 3. All measurements(WMCI, ICD, FW, and IAW) of male group were longer than those of female group significantly in Student's t-test(p<0.01). 4. There was significant correlation between WMCI, ICD, FW, and IAW in Pearson's correlation analysis(p<0.01). 5, The relationship between IAW and ICD shows the strongest correlation among six combinations in linear regression analysis($R^2$=0.753, Y=7.046+0.815X). The FW and IAW could be very reliable guides for the selection of the maxillary anterior artificial teeth.